5.1 Preparation and Start-up

Before starting up the appliance, remove the protective wrapping.

Then carefully clean the working surface and the external parts with
lukewarm water and detergent, using a damp rag to remove all traces
of anti-rust material applied in the factory, then dry with a clean cloth. 

5.1.1 Start-up

Before using the appliance for the first time, thoroughly clean out
the tank (see the chapter 6.3 “Cleaning and taking care of the
machine”).

Before starting up the appliance, check that its specifications (cate-
gory and type of gas used) match those of the family and group of
the gas available locally. 

If not, it is necessary to adapt the appliance to the gas family or
group required (see paragraph 5.1.10 “Conversion and adaptation”). 

To start up the appliance, see the instructions for regular use.

5.1.2 Check of power

The appliances must be used with the specific injectors for the nomi-
nal power.  

The power may be:  

•  the nominal power indicated on the data plate of the appliance;

•  the reduced capacity power.  

These injectors are shown in table 1.

Nominal power is also obtained in respect of the supply pressure:

•  from 15 to 22.5 mbar for gases of the second family (G20/methane)

•  from 25 to 45 mbar for gases of the 3rd family  

(G30/butane, G31/propane) 

The appliance shall not be operated outside the above-mentioned
pressure ranges. 

To adjust power with reduced capacity, use the data in table 1. 

If you wish to further check the nominal power, you may do so by

using a gas meter according to the so-called "volumetric method".  

A simple inspection is usually enough to check if injectors are func-
tioning correctly. 

5.1.3 Checking the input pressure  

Input pressure should be measured using a fluid measuring gauge
(e.g. a gooseneck pipe, min. resolution 0.1 mbar).

Remove lock screw (pos. 22 fig. 1) from the pressure intake tube and
connect the gauge hose: once measurement is complete, replace the
screw and do a seal check using a leak detector spray.

5.1.4 Power check with volumetric method

Using a gas meter and a stopwatch, you can read the volume of gas
output per time unit. The correct volume corresponds to the value
"E" expressed in litres/hour (l/h) or litre/minute (l/min).  

The following formula is used to calculate the value of “E”: 

It is important measure the power when the appliance is in standby
status.  

The calorific power value can be requested from the local gas company. 

The nominal power and the minimum power with respect to the
nominal pressure are obtained by consulting the table for the
adjustment of the gas passage (table 1).

WARNING

There is no pre-adjustment device for the nominal
power.

E =

Power

Operating calorific value

5 - SET-UP FOR OPERATION

0806_GB_42

- GAS PASTA COOKER

04/2008

7

· 12

4

22

6

1

5

3

2

21

24

0

Fig. 1

Summary of Contents for ADN 640

Page 1: ...0806_GB_42 GAS PASTA COOKER Instructions for installation use e maintenance ADN 640 04 2008 ...

Page 2: ...CHARACTERISTICS 0806_GB_42 GAS PASTA COOKER 2 12 04 2008 Supplied by Date Customer Service FAX e mail ...

Page 3: ...1 9 Operator training 8 5 1 10 Conversion and adjustment 8 5 1 11 Replacement of burner injector 8 5 1 12 Replacement of burner pilot injector 8 5 1 13 Setting reduced capacity power 9 5 2 Maintenance 9 5 3 Replacing parts 9 5 3 1 Gas cock 9 5 3 2 Thermocouple 9 5 3 3 Plug 9 5 3 4 Burner 9 6 Instructions for use 10 6 1 Safety cleaning and repair rules 10 6 2 Start up 10 6 2 1 Lighting pilot burner...

Page 4: ...008 1 DIAGRAM ADN 640 45 310 400 400 Data plate 700 Gas 1 2 60 678 55 150 700 Data plate 545 Water load pipe Ø12 Gas 1 2 Water drainpipe 1 GC female Water drainpipe 1 GC female 45 132 45 32 143 117 128 305 408 305 87 Water load pipe Ø12 0 ...

Page 5: ...l purposes Installation repair and use must be carried out by expert personnel These instructions for installation are for our gas pasta cooker set up for the category in the table 1 on pag 5 The data plate is located on the appliance see diagram Beware of inexpert handling 0051 TIPO TYPE CAT KAT GAS GAZ G30 G31 G20 G25 II2H3B P P mbar 30 30 20 II2H3 P mbar 30 37 20 II2H3 P mbar 28 37 20 25 II2L3B...

Page 6: ... is resi stant to thermal and mechanical stress The combustion chamber and flues are made of electrogalvanised steel sheeting 4 3 Assembly 4 3 1 Installation premises The appliance must be installed in a well ventilated room and if possible under a range hood check current regulations The appliance can be installed on its own or with other similar equipment If the appliance is to be installed near...

Page 7: ...ppliance shall not be operated outside the above mentioned pressure ranges To adjust power with reduced capacity use the data in table 1 If you wish to further check the nominal power you may do so by using a gas meter according to the so called volumetric method A simple inspection is usually enough to check if injectors are func tioning correctly 5 1 3 Checking the input pressure Input pressure ...

Page 8: ...r supply thus requiring a second operation check 5 1 10 Conversion and adjustment To change over form one kind of gas to another for example from methane to liquid gas or to another type of gas the use of suitable injectors for the main burner is required in accordance with the table 1 The injectors of the main burners and pilot for different types of gas marked with the relative diameter in hundr...

Page 9: ...nition wire 5 3 1 Gas cock Loosen the fitting of the pipe pos 3 4 and 5 fig 1 of the gas and of the thermocouple pos 6 fig 1 and replace the piece pos 1 fig 1 install in reverse order After the replacement check the seal using a leack detetctor spray 5 3 2 Thermocouple Unscrew the nut pos 6 fig 1 fixing the thermocouple on the cock unscrew the screws pos 36 fig 3 and replace the piece pos 38 fig 3...

Page 10: ...eased start again 6 2 2 Lighting the main burner and temperature adju stment To light the main burner after light the pilot burner place the knob in the maximum or minimum position so that the main burner igni tes Burner power regulation must be done between the max and min supply position of easily selectable interme diate levels To shut off the burner turn the knob to the right to position the m...

Page 11: ... cleaning the tiles favour stainless steel corrosion Particularly for pots and multiple appliances it is not recom mended to load the cooking chamber only with food having a high salt content It is preferable to cook different food together i e fatty dishes or vegetables containing acids Avoid damaging the stainless steel surface in particular with different metals Residues from other metals help ...

Page 12: ... PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Reviews: