Whirlpool ADN 625 Instructions For Installation, Use And Maintenance Manual Download Page 5

0805_GB_42

- GAS FRYERS

04/2008

5

· 12

2 - CHARACTERISTICS OF THE APPLIANCES

3 - TECHNICAL DATA

These appliances are used for professional purposes. Installation,
repair and use must be carried out by expert personnel.

These instructions for installation are for our gas fryers set up for
the category in the table 1 on pag. 5. The data plate is located on
the appliance, see diagram. Beware of inexpert handling.

Model

ADN 625

ADN 626

Description

Gas fryer - 1 vessel

Gas fryer - 2 vessels

N˚ Tank

1

2

Capacity

10 l

10 l + 10 l

Dimensions in mm. (LxDxH)

400 x 700 x 900

800 x 700 x 900

N.

51BS2548

51BS2548

Primary air distance “A” mm

Methane gas G20

Liquid gas G30/G31

Category

Construction type

Air necessary for combustion

Nominal thermal power

Minimum thermal power

Overall thermal power (gas)

Connection pressure

Methane gas 2H

Liquid gas 3+

Gas connection values

Methane gas 2H

Liquid gas 3+

Nozzles Ø 1/100 mm

Main burner 

G20

G30/G31

(HuB = 9.45 kWh/m

3

) in m

3

/h

(HuB = 12.87 kWh/kg) in kg/h

Nominal thermal power

Minimal thermal capacity

Nominal thermal power

Minimal thermal capacity

G20

G30/G31

20 mbar

28/37 mbar

II2H3+

A

m

3

/h

kW

kW

No. of nozzles pilot burner

G20

G30/G31

1

2

0.730

0.540

2 x 145

-

2 x 95

-

Adjustable

20

1

2

1.460

1.080

4 x 145

-

4 x 95

-

Adjustable

2 x 20

Model

ADN 625

14

6.9

-

ADN 626

28

6.9 + 6.9

-

TABLE 1

0051

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

G30/G31

28/37 mbar

G20

20 mbar

Summary of Contents for ADN 625

Page 1: ...0805_GB_42 GAS FRYERS Instructions for installation use e maintenance ADN 625 ADN 626 04 2008 ...

Page 2: ...0805_GB_42 GAS FRYERS 2 12 04 2008 CHARACTERISTICS Supplied by Date Customer Service FAX e mail ...

Page 3: ...aining 7 5 1 10 Conversion and adjustment 7 5 1 11 Replacement of burner injector 8 5 1 12 Replacement of burner pilot injector 8 5 2 Maintenance 8 5 3 Replacing parts 8 5 3 1 Gas valve 8 5 3 2 Safety termostat 8 5 3 3 Thermocouple 8 5 3 4 Plug 8 5 3 5 Burner 9 6 Instructions for use 9 6 1 Safety cleaning and repair rules 9 6 2 Start up 9 6 2 1 Lighting pilot burner 9 6 2 2 Lighting the main burne...

Page 4: ...5_GB_42 GAS FRYERS 4 12 04 2008 683 545 Data plate 150 55 678 60 700 Gas 1 2 45 310 400 34 Gas 1 2 700 Data plate 400 800 Data plate 700 34 Gas 1 2 710 45 Gas 1 2 800 ADN 626 ADN 625 45 34 34 45 1 DIAGRAM ...

Page 5: ...kg h Nominal thermal power Minimal thermal capacity Nominal thermal power Minimal thermal capacity G20 G30 G31 20 mbar 28 37 mbar II2H3 A m3 h kW kW No of nozzles pilot burner G20 G30 G31 1 2 0 730 0 540 2 x 145 2 x 95 Adjustable 20 1 2 1 460 1 080 4 x 145 4 x 95 Adjustable 2 x 20 Model ADN 625 14 6 9 ADN 626 28 6 9 6 9 TABLE 1 0051 TIPO TYPE CAT KAT GAS GAZ G30 G31 G20 G25 II2H3B P P mbar 30 30 2...

Page 6: ...tion chamber and flues are made of electrogalvanised steel sheeting The fryers are fitted with a safety thermostat should the temperatu re of the oil exceed the safety limit the gas is automatically cut off The temperature is set through a thermostat which controls the ignition and extinguishing of the burners 4 3 Assembly 4 3 1 Installation premises The appliance must be installed in a well venti...

Page 7: ...l h or litre minute l min The following formula is used to calculate the value of E It is important measure the power when the appliance is in standby status The calorific power value can be requested from the local gas company The nominal power and the minimum power with respect to the nominal pressure are obtained by consulting the table for the adjustment of the gas passage table 1 WARNING Ther...

Page 8: ...bustion safety Check functioning of the appliance as described in paragraph 5 1 6 Operation control 5 3 Replacing parts All parts must be replaced by authorized technicians only To replace the following parts first remove all the control knobs and control panel after loosening the fixing screws then extract the ignition wire 5 3 1 Gas valve Loosen the fitting of the pipe pos 3 16 17 and 21 fig 1 o...

Page 9: ...am jets or high pres sure equipment it is necessary to switch off the appliance first Before starting to clean the appliance disconnect from the mains Do not use inflammable liquid to clean the appliance Repairs may be carried out only by skilled personnel During repairs the appliance must undergo voltage omnipolar insulation local switch i e safety load cut off switch Noise emission values of the...

Page 10: ...n When cleaning carefully avoid washing the appliance with direct water jets or high pressure water Cleaning must be performed when the appliance is cold Thorough daily cleaning of the appliance after disconnecting it will keep it in perfect working order and make it last longer All steel parts should be cleaned with water and a detergent using a damp cloth do not use abrasive substances or corrod...

Page 11: ...st due to rubbing Newly formed rust spots can be removed with slightly abrasive liquid soaps or fine grained sand paper Larger rust spots can be removed with 2 3 of hot oxalic acid solution If these cleaning products do not do the job a nitric acid 10 treatment is required Attention These treatments can be carried out only by expert personnel according to current regulations 6 6 3 The 2002 96 EC W...

Page 12: ... PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Reviews: