2 - CHARACTERISTICS OF THE APPLIANCES

3 - TECHNICAL DATA

0801_GB_42

- ELECTRIC KITCHENS

7

· 20

04/2008

These appliances are used for professional purposes. 

Installation, repair and use must be carried out by expert personnel.

The data plate is located on the appliance and contains all the data
needed for installation.

Beware of inexpert handling.

Description

Electric range 2 plates 

Electric range 4 plates 

Electric pyroceramic range with 2 plates

Electric pyroceramic range with 4 plates

Electric range 4 plates  - open compartment

Electric range 6 plates  - open compartment

Electric range 4 plates - electric convection oven GN 1/1 multifunction

Electric range 6 plates - electric convection oven GN 1/1 multifunction

Electric range 4 square plates  - open compartment

Electric range 4 square plates - electric convection oven GN 1/1 multifunction

Electric pyroceramic range with 2 plates - open compartment

Electric pyroceramic range with 4 plates - open compartment

Electric pyroceramic range with 4 plates - electric convection oven GN 1/1 multifunction

Dimensions in mm. (LxDxH)

400 x 600 x 270

600 x 600 x 270

400 x 600 x 270

600 x 600 x 270

800 x 700 x 900

1000 x 700 x 900

800 x 700 x 900

1000 x 700 x 900

800 x 700 x 900

800 x 700 x 900

400 x 700 x 900

800 x 700 x 900

800 x 700 x 900

Model

ADN 646

ADN 647

ADN 648

ADN 649

ADN 616

ADN 617

ADN 620

ADN 621

ADN 618

ADN 614

ADN 622

ADN 623

ADN 624

Heating element

Voltage rating

Lead wire Section

1200

-

-

1

2

-

-

-

-

-

-

1

2

2

1800

-

-

-

1

-

-

-

-

-

-

-

1

1

2300

-

-

1

1

-

-

-

-

-

-

1

1

1

Plates
round

Plates

square

1

2

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1

1

-

1

-

-

1

Oven

2500 W

round plates     18

square plates  22x22

1500 W

2000 W

1

2

-

-

4

6

4

6

-

-

-

-

-

-

-

-

-

-

-

-

-

4

4

-

-

-

ADN 646

ADN 647

ADN 648

ADN 649

ADN 616

ADN 617

ADN 620

ADN 621

ADN 618

ADN 614

ADN 622

ADN 623

ADN 624

Model

3.5 kW

7.0 kW

3.5 kW

6.5 kW

8.0 kW

12.0 kW

10.5 kW

14.5 kW

10.4 kW

12.9 kW

3.5 kW

6.5 kW

9.0 kW

Total
Power

2600 W

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

400V 3N or 230V 3

5 x 1.5 mm

or 4 x 2.5 mm

2

5 x 1.5 mm

or 4 x 2.5 mm

2

5 x 1.5 mm

or 4 x 2.5 mm

2

5 x 1.5 mm

or 4 x 2.5 mm

2

5 x 2.5 mm

or 4 x 4 mm

2

5 x 2.5 mm

or 4 x 6 mm

2

5 x 2.5 mm

or 4 x 4 mm

2

5 x 2.5 mm

or 4 x 6 mm

2

5 x 2.5 mm

or 4 x 4 mm

2

5 x 2.5 mm

or 4 x 6 mm

2

5 x 1.5 mm

or 4 x 2.5 mm

2

5 x 1.5 mm

or 4 x 2.5 mm

2

5 x 2.5 mm

or 4 x 4 mm

2

TIPO/TYPE

CAT/KAT

GAS/GAZ

G30

G31

G20

G25

II2H3B/P

P mbar

30

30

20

-

II2H3+

P mbar

30

37

20

-

-

II2H3+

P mbar

28

37

20

-

25

II2L3B/P

P mbar

30

30

II2ELL3B/P

P mbar

50

50

20

20

II2E+3+

P mbar

28

37

20

25

II2H3B/P

P mbar

50

50

20

-

I2E

P mbar

-

-

20

-

-

-

II2H3B/P

P mbar

30

30

II2H3+

P mbar

28

37

20

-

-

-

-

-

I3B/P

P mbar

30

30

I3+

P mbar

28

37

SE

FI

DK

CZ

SK

SI

IT

CH

PT

ES

IE

GB

GR

NL

DE

FR

BE

AT

CH

LU

EE

LV

LT

EE

LV

LT

NO

MT

CY

IS

HU

CY

MOD.

MOD.

ART.

N.

N.

Qn kW

m

3

/h

MADE IN ITALY 

Predisposto a gas: - Gas preset: - Prevu pour gaz:

Eingestelt für Gas: - Preparado para gas: - Geschuckt voor: 

V AC  

kW

Hz

THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH THE LAWS IN FORCE
AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUALS
BEFORE INSTALLING AND USING THE APPLIANCE.
THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.

TABLE 1

Summary of Contents for ADN 614

Page 1: ...0801_GB_42 ELECTRIC KITCHENS Instructions for installation use e maintenance ADN 646 ADN 647 ADN 648 ADN 649 ADN 616 ADN 618 ADN 617 ADN 622 ADN 623 ADN 620 ADN 614 ADN 621 ADN 624 04 2008 ...

Page 2: ...0801_GB_42 ELECTRIC KITCHENS 2 20 04 2008 CHARACTERISTICS Supplied by Date Customer Service FAX e mail ...

Page 3: ... 5 2 Maintenance 9 5 3 Replacing parts 9 5 3 1 Heating element of electric oven GN 1 1 9 5 3 2 Fan electric oven GN 1 1 9 6 Instructions for use 10 6 1 Safety cleaning and repair rules 10 6 2 Start up 10 6 2 1 Electricals plates and Pyroceram 10 6 3 Lighting and shutdown of electric oven GN 1 1 11 6 4 Turning the appliance off in case of breakdown 11 6 4 1 What to do in case of failure 11 6 4 2 Wh...

Page 4: ...0 ADN 617 ADN 616 ADN 618 200 400 200 800 276 5 245 178 5 79 700 710 45 45 79 800 1000 910 45 45 79 1000 200 300 300 200 178 5 245 276 5 79 700 2 0 kW 2 0 kW 2 0 kW 2 6 kW 2 6 kW 2 6 kW 2 6 kW 2 0 kW 200 400 200 800 276 5 245 178 5 79 700 27 546 27 315 600 400 600 315 Electric power Data plate Data plate Electric power Data plate Electric power Electric power Electric power Electric power Electric...

Page 5: ... 678 700 ADN 620 ADN 614 ADN 621 ADN 624 800 700 79 710 45 45 79 800 545 55 690 700 60 678 150 2 0 kW 2 0 kW 2 0 kW 2 0 kW 2 0 kW 2 0 kW 2 0 kW 2 0 kW 2 0 kW 2 0 kW 2 6 kW 2 6 kW 2 6 kW 2 6 kW 200 400 200 800 276 5 245 178 5 79 700 Electric power Electric power Electric power Electric power Data plate Data plate Electric power Electric power Data plate Electric power 1 DIAGRAM ...

Page 6: ...0 79 45 45 710 800 79 27 346 27 400 50 535 430 86 69 30 240 8 60 600 27 546 27 79 600 400 600 79 600 79 600 ADN 648 ADN 649 103 Data plate Electric power Data plate Electric power Electric power Data plate Electric power Electric power Data plate Electric power Data plate Electric power Data plate Electric power 1 DIAGRAM ...

Page 7: ...re 1 2 1 1 1 1 Oven 2500 W round plates 18 square plates 22x22 1500 W 2000 W 1 2 4 6 4 6 4 4 ADN 646 ADN 647 ADN 648 ADN 649 ADN 616 ADN 617 ADN 620 ADN 621 ADN 618 ADN 614 ADN 622 ADN 623 ADN 624 Model 3 5 kW 7 0 kW 3 5 kW 6 5 kW 8 0 kW 12 0 kW 10 5 kW 14 5 kW 10 4 kW 12 9 kW 3 5 kW 6 5 kW 9 0 kW Total Power 2600 W 400V 3N or 230V 3 400V 3N or 230V 3 400V 3N or 230V 3 400V 3N or 230V 3 400V 3N or...

Page 8: ...n is equipped with an insulated handle and a hinge with balanced spring The insulation of the cooking chamber is rockwool Electric version GN 1 1 ventilated The heating element is place in the rear around the fan and is pro tected by a bulkhead Temperature adjustment between 50 C and 300 C is made by a thermostat connected to a switch The lighting of the heating element is indicated by 2 indicator...

Page 9: ...nt of electric oven GN 1 1 Unplug the appliance from the electrical mains To remove the heating element pos 6 fig 2 remove the rear bulk head unscrew the screws fixing the the heating element to the oven pull the heating element forward with relative wires Disconnect the wires and install a new heating element in reverse order 4 3 5 Equipotential The appliance must be hooked up to a unipotential s...

Page 10: ... may be carried out only by skilled personnel During repairs the appliance must undergo voltage omnipolar insulation local switch i e safety load cut off switch Noise emission values of the appliance in operation are below 70dB A This value is compulsory according to certain national safety standards WARNING Attention The manufacturer declines all responsibility concern ing mistakes included in th...

Page 11: ...age due to mechanical actions The inactive coat builds up or re builds up faster if the steel comes in contact with running water containing oxygen A more powerful effect is given by oxidative acids nitric acid oxalic acid These acids are used if the steel has undergone strong chemi cal stresses hence generally losing its inactive coat The inactive layer can be chemically damaged or jeopardized by...

Page 12: ...ent collection centre or returned to the reseller when buying a new equivalent item of equipment The user is responsible for delivering the unit at the end of its life to the appropriate collection facilities Failure to do so shall result in the user being subject to the penalties prescribed by the legislation in force on waste Suitable separated collection so that the unit no longer used can be s...

Page 13: ...300 w 220 w 175 w R1 R2 6 5 4 3 2 1 0 5 P3 P1 P2 2 1 3 3 4 1200 w 700w 340 w 340 w 170 w 125 w R3 6 5 4 3 2 1 0 5 P3 P1 P2 2 1 3 3 4 2300 w 1200 w 600 w 600 w 300 w 230 w R4 ADN 646 1xR1 1xR2 ADN 648 1xR3 1xR4 ADN 622 1xR1 1xR2 mA B1 B2 H1 R1 R2 R3 R4 Terminal board Commutator plate rear Commutator plate front Green indicator light Heating element 1500 W Heating element 2000 W Heating element 1200...

Page 14: ... R3 6 5 4 3 2 1 0 5 P3 P1 P2 2 1 3 3 4 1800 w 1000 w 500 w 500 w 250 0 w 180 0 w R4 6 5 4 3 2 1 0 5 P3 P1 P2 2 1 3 3 4 2300 w 1200 w 600 w 600 w 300 w 230 w R5 Position plates B1 plate rear left B2 plate front left B3 plate rear right B4 plate front right ADN 647 2xR1 2xR2 ADN 649 2xR3 1xR4 1xR5 ADN 616 4xR2 ADN 623 2xR3 1xR4 1xR5 mA B1 B2 B3 B4 H1 R1 R2 R3 R4 R5 Terminal board Commutator plate re...

Page 15: ...2 1 3 3 4 2300 w 1200 w 600 w 600 w 300 w 230 w R5 Position plates B1 plate rear left B2 plate front left B3 plate rear right B4 plate front right 6 5 4 3 2 1 0 5 P3 P1 P2 2 1 3 3 4 2000 w 1150 w 850 w 300 w 220 w 175 w R1 ADN 620 4xR1 1xR6 ADN 624 2xR3 1xR4 1xR5 1xR6 mA B1 B2 B3 B4 A1 F1 H1 H2 MV R1 R3 R4 R5 R6 Terminal board Commutator plate rear left Commutator plate front left Commutator plate...

Page 16: ... R1 B6 5 2 1 1 2 3 4 4 3 B5 B5 B6 B6 6 5 4 3 2 1 0 5 P3 P1 P2 2 1 3 3 4 2000 w 1150 w 850 w 300 w 220 w 175 w R1 Position plates B1 plate rear left B2 plate front left B3 plate rear central B4 plate front central B5 plate rear right B6 plate front right ADN 617 6xR1 mA B1 B2 B3 B4 B5 B6 H1 R1 Terminal board Commutator plate rear left Commutator plate front left Commutator plate rear central Commut...

Page 17: ... 6 5 4 3 2 1 0 5 P3 P1 P2 2 1 3 3 4 2000 w 1150 w 850 w 300 w 220 w 175 w R1 Position plates B1 plate rear left B2 plate front left B3 plate rear central B4 plate front central B5 plate rear right B6 plate front right ADN 621 6xR1 1xR6 mA B1 B2 B3 B4 B5 B6 A1 F1 H1 H2 MV R1 R6 Terminal board Commutator plate rear left Commutator plate front left Commutator plate rear central Commutator plate front...

Page 18: ...4 3 R1 B4 5 2 1 1 2 3 4 4 3 B1 B1 B3 B2 B2 B4 B3 B4 6 5 4 3 2 1 0 B1 5 P3 P1 P2 2 1 3 3 4 2600 w 1800 w 1200 w 600 w 400 w 270 w R1 Position plates B1 plate rear left B2 plate front left B3 plate rear right B4 plate front right ADN 618 4xR1 mA B1 B2 B3 B4 H1 R1 Terminal board Commutator plate rear left Commutator plate front left Commutator plate rear right Commutator plate front right Green indic...

Page 19: ... H2 F1 A1 A1 R6 Position plates B1 plate rear left B2 plate front left B3 plate rear right B4 plate front right 6 5 4 3 2 1 0 B1 5 P3 P1 P2 2 1 3 3 4 2600 w 1800 w 1200 w 600 w 400 w 270 w R1 ADN 614 4xR1 1xR6 mA B1 B2 B3 B4 A1 F1 H1 H2 MV R1 R6 Terminal board Commutator plate rear left Commutator plate front left Commutator plate rear right Commutator plate front right Switch oven Thermostat oven...

Page 20: ... PRINTING ERRORS DUE TO ITS POLICY OF CONTINUAL PRODUCT IMPROVEMENT THE MANUFACTURER RESERVES THE RIGHT TO MAKE ANY CHANGES DEEMED NECESSARY THE MANUFACTURER CANNOT BE HELD RESPONSIBLE IF THE INSTRUCTIONS CONTAINED IN THIS MANUAL ARE NOT OBSERVED WHIRLPOOL EUROPE srl V le Guido Borghi 27 I 21025 Comerio VA ...

Reviews: