Installation parts supplied
H. 1 Window-lock bracket
I. 1 foam seal
J. 6 #10 x 3/8 in. Phillips-head screws
K. 3 3/4 in. slotted round-head screws
L. 2 side curtains
H
I
J
K
L
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Electrical Shock Hazard
Wiring requirements
Wiring requirements
Power supply cord
plug outlet
• 3-wire
• Single-phase
• AC only
• 60 hertz
• 115 volt (103.5 min. -
126.5 max.)
• 0-12 amperes
• 15-amp time-delay
fuse or circuit breaker
• 14 gauge copper
wiring
WARNING
Specific electrical requirements are listed in the chart.
Follow the requirements for the type of plug on the
power supply cord.
Recommended ground method
For your personal safety, this air conditioner must be
grounded. This air conditioner is equipped with a
power supply cord having a 3-prong ground plug. To
minimize possible shock hazard, the cord must be
plugged into a mating, 3-prong ground-type outlet,
grounded in accordance with all local codes and
ordinances. If a mating outlet is not available, it is the
customer’s responsibility to have a properly grounded,
3-prong outlet installed by a licensed installer.
It is the customer’s responsibility:
• To contact a qualified electrical installer.
• To assure that the electrical installation is adequate
and in conformance with National Electrical Code,
ANSI/NFPA 70 — latest edition*, and all local codes
and ordinances.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
Electrical requirements