background image

®

24" Electric Washer/Dryer

PRODUCT MODEL NUMBER

OVERALL DIMENSIONS

RECESSED AREA AND CLOSET INSTALLATION

EXHAUST VENTING

LTE5243D

Electrical:

A 120/240-volt, 60-Hz, AC-only,

electrical supply (120/208-volt electrical supply, if
specified on the serial/rating plate) is required on a
separate 30-amp circuit, fused on both sides of the
line. A time-delay fuse or circuit breaker is
recommended. 

Exhaust venting:

Exhaust your dryer to the

outside. Four-inch diameter vent is required. Rigid
or flexible metal exhaust vent must be used. Do
not use plastic or metal foil vent. Exhaust outlet
hood must be at least 12 inches from the ground
or any object that may be in the path of the
exhaust.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. 8542748 Rev. A

11-01-04

Plan installation to use the fewest number of elbows
and turns.
Maximum length of the exhaust system depends
upon the type of vent used, number of elbows and
the type of exhaust hood. The maximum length for
both rigid and flexible vent is shown in the chart.

Additional clearance for wall, door and floor molding may be required. 
Rear clearance may be 0 in. when house exhaust system is lined up directly with dryer exhaust.

*

Vent Length Chart

NOTE:

 Side exhaust adds a 90

°

 turn inside the washer/dryer. To 

determine maximum exhaust length, add one 90

°

 turn to the 

chart.

Number of 
90

 turns 

or elbows 

Type of Vent

Box or 
Louvered 
hoods

Angled 
hoods

0

Rigid metal

Flexible metal

43 ft (13.1 m)
30 ft (9.1 m)

36 ft (11.0 m)
24 ft (7.3 m)

1

Rigid metal

Flexible metal

33 ft (10.1 m)
24 ft (7.3 m)

26 ft (7.9 m)
18 ft (5.5 m)

2

Rigid metal

Flexible metal

24 ft (7.3 m)
16 ft (4.9 m)

16 ft (4.9 m)
10 ft (3.0 m)

 1. Louvered hood style
 2. Box hood style

     4"
(10.2 cm)

      4"
(10.2 cm)

2

1

   4"

(10.2 cm)

(6.4 cm)

Angled hood style

* Most installations require a

minimum 5-1/2 in. (14 cm)
clearance behind the dryer for
the exhaust vent with elbow.

    A. Recessed area

B. Side view - closet or confined area
C. Closet door with vents

0"

 0"

3"

3"

48 in.

24 in.

27

23

7

/

8

1

/

4

"

5

1

/

2

"

1"

"

(0 cm)

(0 cm)

(2.5 cm)

(60.64 cm)

(69.22 cm)

(14 cm)

(7.6 cm)

(7.6 cm)

(310 cm )

(155 cm )

2

2

2

2

 0"
(0 cm)

A

B

C