background image

5

A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is 
required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this oven be provided.

Electronic ignition systems operate within wide voltage limits, 
but proper grounding and polarity are necessary. Check that 
the outlet provides 120-volt power and is correctly grounded. 

The wiring diagram is located in the upper control 
compartment in a clear plastic bag.

Gas Supply Requirements

Observe all governing codes and ordinances. 

IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 

IMPORTANT: Leak testing of the oven must be conducted 
according to the manufacturer’s instructions.

Type of Gas 

Natural gas:

This oven is design-certified by CSA International for use with 
Natural gas or, after proper conversion, for use with LP gas. 

This oven is factory set for use with Natural gas. See “Gas 
Conversions” section. The model/serial rating plate located 
behind the broiler drawer on the right-hand side oven front 
frame has information on the types of gas that can be used. If 
the types of gas listed do not include the type of gas 
available, check with the local gas supplier.

LP gas conversion:

Conversion must be done by a qualified service technician.

No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See “Gas 
Conversions” section.

Gas Supply Line 

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the oven 
location. A smaller size pipe on longer runs may result in 
insufficient gas supply. Pipe-joint compounds that resist the 
action of LP gas must be used. Do not use TEFLON

®†

 tape. 

With LP gas, piping or tubing size can be ½" (1.3 cm) 
minimum. Usually, LP gas suppliers determine the size and 
materials used in the system.

Flexible metal appliance connector:

If local codes permit, a new CSA design-certified, 4 to 5 ft 
(122 to 152.4 cm) long, ½" (1.3 cm) or ¾" (1.9 cm) I.D., 
flexible metal appliance connector may be used for 
connecting oven to the gas supply line. 

A ½" (1.3 cm) male pipe thread is needed for connection 
to the female pipe threads of the inlet to the appliance 
pressure regulator. 

Do not kink or damage the flexible metal tubing when 
moving the oven.

Rigid pipe connection: 

The rigid pipe connection requires a combination of pipe 
fittings to obtain an in-line connection to the oven. The rigid 
pipe must be level with the oven connection. All strains must 
be removed from the supply and fuel lines so oven will be 
level and in line.

Must include a shutoff valve: 
The supply line must be equipped with a manual shutoff 
valve. This valve should be located in the same room but 
external to the oven opening, such as an adjacent cabinet. It 
should be in a location that allows ease of opening and 
closing. Do not block access to shutoff valve. The valve is for 
turning on or shutting off gas to the oven.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

A. Gas supply line
B. Shutoff valve “open” position

C. To range

†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.

A

B

C

Summary of Contents for 24" (61.0 CM) GAS SINGLEAND DOUBLE BUILT-IN OVEN

Page 1: ...ce W10526072A You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others are very important We have provided many important sa...

Page 2: ...ier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you smell gas instructions IMPORTANT Do not install a ventilation system that blows air downward toward this gas cooking appliance This type of ventilation system may caus...

Page 3: ...e materials used will not discolor delaminate or sustain other damage This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194 F 90 C Product Dimensions Single Oven Cabinet Dimensions Single Oven Single Oven Installed in Cabinet NOTE For gas supply pipe provide a 3 x 3 7 6 cm x 7 6 cm openin...

Page 4: ...ectrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association 1 Batterymarch Park Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 22 56 8 cm max recessed width B 46 117 6 cm max overall height C 23 60 6 cm overall width D 22 57 5 cm max recessed depth E 44 11...

Page 5: ...ation A smaller size pipe on longer runs may result in insufficient gas supply Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape With LP gas piping or tubing size can be 1 3 cm minimum Usually LP gas suppliers determine the size and materials used in the system Flexible metal appliance connector If local codes permit a new CSA design certified 4 to 5 ft 122 ...

Page 6: ... installation 2 To avoid floor damage set the oven onto cardboard prior to installation Do not use handle or any portion of the front frame or trim for lifting 3 Remove the shipping materials and tape from the oven 4 Remove the hardware package from inside the bag containing literature 5 Remove and set aside racks and other parts from inside the oven 6 Move oven and cardboard close to the oven s f...

Page 7: ...ainst seal area of oven front frame when pushing oven into cabinet Do not push against outside edges 2 Push oven completely into cabinet and center oven into cabinet cutout A Gas pressure regulator B Use pipe joint compound C Adapter must have male pipe thread D Flexible connector E Manual gas shutoff valve F or gas pipe G Use pipe joint compound H Adapter A Gas pressure regulator B Gas supply lin...

Page 8: ...es no adjustment When the oven control is turned on a glow bar igniter heats and ignites the gas Check Operation of Oven s 1 Turn power on The time should flash in the display 2 Check that the oven door s is closed 3 Turn on the oven s Broil function See the Use and Care Guide for instructions If oven s does not operate check the following Household fuse is intact and tight or circuit breaker has ...

Page 9: ...f valve closed position C Gas supply line WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized ...

Page 10: ...ete conversion has occurred 3 Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold NaturalGasConversion 1 Turn manual shutoff valve to the closed position 2 Unplug oven or disconnect power To Convert Gas Pressure Regulator 1 Locate gas pressure regulator in bottom compartment IMPORTANT Do not remove the gas pressure regulator A Natu...

Page 11: ... from inside the broiler cavity 2 Screw the burner orifice hood away from the pins There will be approximately 1 to 2 turns NOTE On units using Eaton Oven Safety Valve screw the burner orifice hood away from the pin There will be approximately 1 to 2 turns 3 Adjust burner air shutter to the widest opening that will not cause the flame to lift or blow off the burner when cold A Regulator pin B Regu...

Page 12: ...12 ...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...W10526072A 2012 Whirlpool Corporation All rights reserved 7 12 Printed in U S A ...

Reviews: