background image

1

Electricity  parameter

Rated voltage 

Rated electric current 

Reference circuit voltage

220VAC

2750W

<4A

12V

Rated power

 2

Electric installation

2.1 

2.2  

 

2.3  

2.4  

    

 power supply's establishment should be compled with nation security standard, voltage

       and frequency also shoule be accord withproduct's nameplate.Especially install creep-

       age protect switch and also check whether can connect with ground.

The wire collected to the massage bathtub should be fitting permanent., and  the wire 

        should be a three-core wire, the sectional acreage of  each core cannot less  than 12A. 

        when wire pass the wall,it should be use bushing for protection until the AC outlet.

Ground wire of  bathtub should be test whether works with house appliance ground wire.

The wire end of electricity control box should connect to the control panel, water bottom

light, loudspeaker, electrical engineering and the detector protection respectively.

3

Water supply device

3.1 

                                            

This device's hydraulic pressure is 0.2-0.4Mpa.

3.2 The water supply characteristics on the wall: The cold or hot water supplies inside the 

       bathroom also establish in the shelter of the massage tub, use the hose to connect with

       the cold or hot joint of the tub. the pipe towards is decide by the customer, the machine 

       do not go with the hose.

4.1 

    

4.2  

4.3  

4.4  

4.5 

 

    
    

                                    

 Before install, must consider the place of install massage bathtub whether can support

this device's pressure.

Place the massage bathtub on the install position, adjust level to make the drain system 

        smooth.

Adjust the leg's screw to make sure all of the screw touch ground completely.

Install the drain hose, and make some measure to against on the connecter.

Fix cold and hot water-pipe well, then install the showerhead. And then put drain into 

downcomer, finally connect with power and make sure whether device connected with 

ground can work.

5

Using Method

4

Installation introduction

5.1 

    
    

5.2 

5.3 

    

Turn on faucet, adjust water's temperature, add water to the massage bathtub.when the 

highest water level  exceed the highest nozzle  about 20-30mm and reach the detector, 

press the switch button to let the electric machine.

Revolve the adjust switch ,and choose the proper  surf  pressure.

After finishing if should turn off pump at first, then open drain button,when water is all out ,

please make a clean of bathtub to keep in good.

 

Page

 

2

 

of

 

7

6

Clean and keep in good condition

.

.

6.1 usually use soft cloths and general liquid cleanser can wash away dirt , but forbid to use the 

      cleanser with acetone or the ammon ia comp osition;when  disinfect, forbid to use the disinfector

      contained the formal dehyde.

6.2 the dirty spot of surface can use the toothpaste to wipe with the soft cloth 

6.3 to the low-grade chafe of the surface or burned by cigarette, can soak in water to whet with 2000# 

      levigation sand paper, then polishing.

6.4 If the electroplate piece contain stain, use the soft cloth to wipe lightly, avoid to wiping with coarse cloth

6.5 often clean up the backwater net cover, prevent it from stop;

Massage

 

bathtub

Massage

 

bathtub

 

Page

 

5

 

of

 

7

      1

.Features(371)

               1

  

Automatic testing water level by  microcomputer. 

               2

Surfing function .

               3

Bubble bath massage  function .

               4

External thermostat function 

Configuration Options 

               5

Underwater light .

             6

Ozone sterilization function 

Configuration Opt ions 

2.Specifications

                                                        

1

AC190V--240V   50-60Hz                              

Power supply 

                                                                 
                                                                        5

1500V   1min

Dielectric strength

6

<0.25mA                     

Leak current 

7

Lamp

AC12V   10W

8

Ozone 

AC12V    8W

Configuration Options

                                             4

AC220V   2W

Heater power 

Configuration Options

9

IPX4

Waterproof grade

                                             2

Water pump1 load

      AC220V-240V     1500W

                                             3

 pump2 load

      AC220V-240V    750W

Water

3.Install sketch

the configuration of installation should be accroding to 

                                                             the selected model

12V10W

Lamp 

Water pump 

Water level sensor 

Electric  box

 16A   Plug

Heater 

220V/2KW

Control panel 

AC220V

INPUT

Ozone  devi ce 

AC12V /8W

O K

Water pump 

Summary of Contents for 215WP

Page 1: ...quired to consider load capacity of power supply circuit otherwise it may influence the normal working of the system or cause accident 6 During erection all the electric appliances and electric parts shall be provided with moisture resistant measures 1 The system must be erected by qualified technical person and the leakage switch shall be mounted in place of easy control 2 It must be connected fi...

Page 2: ...unction Configuration Options Press or to select the heating icon as shown to the right To press OK for ON or OFF OK 2 Surfing function Perss or to select the water pump icon as shown to the right To press OK for ON or OFF OK Notice The water pump is limited by water level it only be launched under the condition of water level If short of water the the will flicker water pump can not start The pum...

Page 3: ...ected with ground can work 5 Using Method 4 Installation introduction 5 1 5 2 5 3 Turn on faucet adjust water s temperature add water to the massage bathtub when the highest water level exceed the highest nozzle about 20 30mm and reach the detector press the switch button to let the electric machine Revolve the adjust switch and choose the proper surf pressure After finishing if should turn off pu...

Page 4: ...in bathtub 8 6 bathtub s temperature cann t higher than people average temperature and the best is 32 37centigrade 8 7 after shower please cut off power 8 8 if have these situation please do not enter into massage bathtub 8 8 1 younger than 4 years old s child 8 8 2 blood circulation unstabled people 8 8 3 sot 8 8 4 suffer from flu 8 8 5 heart disease 8 8 6 already have sauna 8 8 7 after meal in h...

Reviews: