Technical data
Regenerating valve
Voltage
220/ 240 V
Frequency
50/ 60
Hz
Resistance
3.13
k
Ω
Valve for zone washing
Voltage
220 - 240 V
Frequency
50/ 60
Hz
Resistance
4
k
Ω
Coil of dispenser
Voltage
220/ 240 V
Frequency
50/ 60
Hz
Resistance
1.3
k
Ω
Reed contacts
flow meter
salt control
rinse aid control
NTC
20 ˚C
58.1
k
Ω
25 ˚C
47.1
k
Ω
30 ˚C
38.2
k
Ω
40 ˚C
25.4
k
Ω
50 ˚C
17.2
k
Ω
60 ˚C
11.8
k
Ω
70 ˚C
8.3
k
Ω
80 ˚C
6
k
Ω
85 ˚C
4
k
Ω
Regeneration
Volume
300
cm
3
Position 0
after wash cycles
12
water hardness
0 - 5
˚dh
0 - 0.9
mmol/l
0 - 9
˚Fh
Position 1
after wash cycles
10
water hardness
6 - 10
˚dh
1 - 1.8
mmol/l
10 - 18
˚Fh
Position 2
after wash cycles
7
water hardness
11 - 15
˚dh
1.9 - 2.7
mmol/l
19 - 27
˚Fh
Position 3
after wash cycles
5
water hardness
16 - 21
˚dh
2.8 - 3.7
mmol/l
28.37
˚Fh
Position 4
after wash cycles
3
water hardness
22 - 28
˚dh
3.8 - 5.0
mmol/l
38 - 50
˚Fh
Position 5
after wash cycles
2
water hardness
29 - 35
˚dh
5.1 - 6.3
mmol/l
51 - 63
˚Fh
Position 6
after wash cycles
1
water hardness
36 - 60
˚dh
6.4 - 10.7 mmol/l
64 - 107
˚Fh
Salt consumption
for regeneration
77
g
Number of cycles
with 2 kg salt
26
Accesory
If you need spare parts apart from
the spare part list have a look