Page 4
1
2
3
4
5
6
Rear View of Pin Housing
REFERENCE
POINT
9
12
8
11
7
10
1
2
3
4
5
6
7
8
9
1
0
11
1
2
LAMP
1
LAMP 2
LAMP
3
LAMP 4
LAMP 5
LAMP 6
LAMP 7
LAMP 8
+BATTERY
N/C
N/C
N/C
BROWN
RED
ORANGE
YELLOW
GREEN
BLUE
VIOLET
GREY
WHITE
N/C
N/C
N/C
PIN
TO:
WIRE
PIN
TO:
WIRE
WARNING:
All customer supplied wires, that connect to the
positive terminal of the battery, must be sized to supply at
least 125% of the maximum operating current, and fused
“At the Battery” to carry the load.
Fig. 4
Dip Switch Specifications...
Configuration #1 (Default) = All Down
Pattern Control Knob =
LEFT
Individual lamps light sequentially from Left to Right with the
last lamp displaying a triple flash pattern. EX. 2 - 3 - 4 - 5 - 6 - 7
- 8 - 8 - 8
Pattern Control Knob =
RIGHT
Individual lamps light sequentially from Right to Left with the
last lamp displaying a triple flash pattern. EX. 7 - 6 - 5 - 4 - 3 - 2
- 1 - 1 - 1
Pattern Control Knob =
SPLIT
Lamps light in pairs that begin in the middle and move out-
wards with the last two lamps displaying a triple flash pattern.
EX. 4+5 - 3+6 - 2+7 - 1+8 - 1+8 - 1+8
Pattern Control Knob =
FLASH
Alternating pairs of lamp light. EX. 4+5 - 2+7
Configuration #2 = 1,2,4 Down / 3 Up
Pattern Control Knob =
LEFT
Individual lamps light sequentially from Left to Right with the
last lamp displaying a Double Flash Pattern. EX. 2 - 3 - 4 - 5 - 6
- 7 - 8 - 8
Pattern Control Knob =
RIGHT
Individual lamps light sequentially from Right to Left with the
last lamp displaying a Double Flash Pattern. EX. 7 - 6 - 5 - 4 - 3
- 2 - 1 - 1
Pattern Control Knob =
SPLIT
Lamps light in pairs that begin in the middle and move out-
wards with the last two lamps displaying a Double Flash Pat-
tern. EX. 4+5 - 3+6 - 2+7 - 1+8 - 1+8
Pattern Control Knob =
FLASH
Alternating pairs of lamp light using a double flash sequence.
EX. 4+5 - 4+5 - 2+7 -2+7
Configuration #3 = 1,2,4 Down / 3 Up
Pattern Control Knob =
LEFT
Lamps light progressively from Left to Right with lamps remain-
ing on until the pattern repeats. EX. 2>3>4>5>6>7>8
Pattern Control Knob =
RIGHT
Lamps light progressively from Right to Left with lamps remain-
ing on until the pattern repeats. EX 7>6>5>4>3>2>1
Pattern Control Knob =
SPLIT
Lamps light in pairs that begin in the middle and move outwards
with lamps remaining on until the pattern repeats. EX.
4+5>3+6>2+7>1+8
Pattern Control Knob =
FLASH
Alternating pairs of lamp light using a double flash sequence.
EX. 4+5 - 4+5 - 2+7 - 2+7
Configuration #4 = 1,2 Down / 3,4 Up
Pattern Control Knob =
LEFT
Lamps light in a solid flash pattern. EX. 2 - 8 Flash Simultane-
ously
Pattern Control Knob =
RIGHT
Lamps light in a solid flash pattern. EX. 7 - 1 Flash Simultane-
ously
Pattern Control Knob =
SPLIT
Lamps light in a solid flash pattern. EX. 1 - 8 Flash Simultane-
ously
Pattern Control Knob =
FLASH
Alternating pairs of lamp light using a double flash sequence.
EX. 4+5 - 4+5 - 2+7 - 2+7
(Continued on Next Page)