MANUAL HI/LOW
PHOTOCELL HIGH/LOW
DAY ON - NIGHT OFF
DAY OFF - NIGHT ON
ALTERNATING SYNC
SIMULTANEOUS SYNC

OFF

OFF

ON

3

OFF

OFF

OFF

4

FUNCTION

2

ON

OFF

OFF

1

ON

ON

OFF

OFF

D I P S W I T C H VA R I A B L E S

OFF OFF

OFF

OFF

OFF OFF

OFF

OFF OFF

ON

OFF

MULTIPLE STROBES

(4 MAXIMUM)

ALWAYS SIMULTANEOUS

DIP SWITCH 3 ON

YELLOW

BLUE

BLUE

BLUE

Multiple Light Option: Synchronization:

To Run Several Lights in the Synchronized Mode:

Connect your lights as shown in figure 1. With dip switch 3 on, the lights will flash 
simultaneously. You may run up to 4 lights at a time.  

Interfacing Multiple Units in an Alternating or Simultaneous Flash Pattern:

Connect your lights as shown in figure 2. With dip switch 3 OFF, the 2 lights will blink 
alternating. With dip switch 3 on, they will blink simultaneously.

CUSTOMER OPTIONS

Hi/Low Intensity Option:

1.

Take  the  dome  and  strobe  power  supply  assembly  apart
(see “S360D Disassembly Procedure”).

2.

Locate the violet (looped) wire, cut it at pin 2 and run it out of
the bottom of the unit with the black and red wires (Fig. 7).

3.

Reassemble the unit.

4.

Connecting the violet wire to ground will cause the S360D to
operate  in  high  power  mode.  Removing  this  wire  from
ground  forces  the  S360D  into  low  power  mode.  A  two-
position  switch  can  be  installed  so  that  the  operator  can
easily alternate between high and low power operation (see
“Switch Control Wiring Schematics Chart”).

Flash Pattern Options:

The  default  flash  pattern  for  the  S360D  is  CometFlash®.  You
may choose from several other patterns by making a few simple
changes.

1.

First  take  the  unit  apart  as  described  under  “S360D
Disassembly Procedure”.

2.

Now find the input control pigtail assembly in your parts bag,
and plug it in to the extra connector coming out of the strobe
power supply assembly.

3.

Next run the brown and white wires out through the center of
the base as shown in Fig. 7.

4.

Reassemble  the  unit  and  you  are  ready  to  choose  your
options.  IMPORTANT:  while  re-assembling,  make  sure  you
line up the notch, wire slot and alignment tab (Fig. 3).

To Select SingleFlash: 

Ground the white wire and tape off the

brown wire.

To Select DoubleFlash:

 Ground the brown wire and tape off the

white wire.

To  Select  ActionFlash™:

  Ground  both  the  white  and  brown

wires.

DIP SWITCH 3

OFF - ALTERNATING

ON - SIMULTANEOUS

YELLOW

BLUE

Fig. 1

Fig. 2

Dip Switch Options:

There  are  several  options  you  can  utilize  by  changing  the  dip
switch settings.

Manual High/Low Intensity Mode:

 You may run your strobe at

either high or low intensity by turning all the dip switches off then
following the instructions under “Hi/Low Intensity”.

Automatic  Photocell  High/Low  Intensity  Mode  (optional):

The  optional  Photocell  will  automatically  adjust  the  intensity  of
the strobe light according to the ambient light (darkness switches
the beacon to low power, while daylight switches the beacon to
high power). To engage this function you must turn dip switch 1
on. Then clip the violet wire and tape it off (see “Hi/Low Intensity
Option”).  Now  the  photocell  option  is  always  engaged.  If  you
want to be able to turn this function on or off manually, you must
also  attach  the  violet  wire  to  a  switch  that  will  ground  or
disconnect it. When you switch to “ground” the light will always be
at  high  intensity.  When  you  switch  to  “disconnect”  the  light  will
return to the photocell function.

Photocell  Mode  (Day  On):

  If  you  want  your  strobe  to  turn  on

automatically during the day and off at night, turn dip switch 2 on.

Photocell  Mode  (Day  Off): 

If  you  want  your  strobe  to  turn  off

automatically during the day and on at night, turn dip switch’s 1
and 2 on.

NOTE:

 Both “C” and “D” are usually used for remote applications.