Whelen Engineering Company Responder DX Series Installation Manual Download Page 2

Page 2

The  Responder®  DX

 

Series, 

which  includes  Models  R2DX,

R3DX, R4DX, R5DX and R6DX uses a base design that enables
deck, permanent or magnetic (optional) mounting. 

Installation: Permanent Mount

1.

Check to make sure that no vehicle components will interfere
with the selected mounting location of this unit.

2.

Remove the outer lens  by unscrewing the four  Phillips  Pan
Head screws shown in Fig. 1. Position the Responder on the
proposed mounting location.  Using  an awl  or other suitable
tool, scribe the mounting surface where the mounting holes
are to be drilled.

Caution: Mounting the Responder will require drilling. It is
absolutely  necessary  to  make  sure  that  no  other  vehicle
components  will  be  damaged  in  the  process.  Check  both
sides of the mounting surface before starting and if damage
is possible, select a different mounting location.

3.

Drill the mounting holes in the areas scribed in step 2. The
diameter of these holes will be determined by the size of the
mounting  hardware  (#10  x  1”)  and  the  thickness  of  the
mounting surface.

4.

Using the supplied #10 x 1” Phillips Pan Head Sheet Metal
Screws, secure the Responder to the mounting location and
remount the lens in its original location.

IMPORTANT:

 The outer surfaces of this product may be cleaned

with mild soap and water. Use of any other chemicals may void
product warranty. Do not use a pressure washer.

Removing the Halogen Bulb (R2-, R3- & R4DX):

1.

Remove  the  outer  lens  as  outlined  previously.  Insert  a  flat-
blade  screw  driver  into  the  space  between  the  lamp  holder
and the snap-in assembly. Gently rotate the screw driver as
shown in Fig. 2. Repeat this action until the bulb is loose. Pull
the bulb in an upward direction until it is free.

2.

Verify that the replacement bulb is the correct wattage by the
part  numbers  marked  on  the  bulb  assembly  (see  “Part
Numbers”). Insert the alignment tab of the new bulb into the
lamp holder and press downwards to lock the bulb into place.

Replacing the Strobe Assembly (R5DX-only):

NOTE:  Do  not  begin  this  procedure  unless  the  R6DX  has
been disconnected from power for at least 10 minutes!

1.

Remove the outer lens as outlined previously and disconnect
the strobe assembly from its power supply.

2.

Using a Phillips screwdriver, remove the retaining ring from
the strobe assembly.

3.

Remove the lens and lift the strobe assembly away from the
base. Disconnect the strobe tube assembly from the harness
plug.

4.

Reverse this procedure to install the new assembly.

Replacing the Strobe Assembly (R6DX-only):

NOTE: Do not begin this procedure unless the R6DX has been
disconnected from power for at least 10 minutes!

1.

Remove the outer lens as outlined previously and disconnect
the strobe assembly from its power supply.

2.

Unscrew the lens from the strobe assembly base. Locate and
remove  the  two  strobe  assembly  mounting  screws  from  the
strobe assembly base.

3.

Reverse this procedure to install the new assembly.

Wiring to Power:

1.

Install  an  SP/ST  switch  (customer  supplied)  onto  the  RED
wire.  Using  appropriately  sized  wires,  extend  the  RED  and
BLACK wires to the battery. 

WARNING!  All  customer  supplied  wires  that  connect  to  the
positive  terminal  of  the  battery  must  be  sized  to  supply  at
least 125% of the maximum operating current and FUSED at
the  battery  to  carry  that  load.  DO  NOT  USE  CIRCUIT
BREAKERS WITH THIS PRODUCT!

2.

Connect  the  BLACK  wire  directly  to  the  vehicle’s  chassis
ground (typically adjacent to the battery).

3.

Connect the RED wire to one end of the user supplied fuse
block  (see  table  for  the  correct  fuse  application  for  your
specific model). After the  fuse block is in place, connect the
RED wire to the PO) terminal of the battery.

After this connection has been made, inspect the circuit wires and
make sure they are wired correctly. Replace the fuse if blown with
one  of  an  identical  amp.  rating  as  the  original.  If  the  fuse  blows
after  installation  or  activation,  contact  Whelen  Engineering
Technical Support.

Low Power Control Wire / VIOLET (R6DX-only)

The type of switch used is dependant on how the operator wishes
the Hi/Low feature to function:

Latching Mode:

 

By  applying  +voltage  to  the  Violet  wire  for  less

than 1 sec., the power supply is “latched” into low power operation.
The unit must be turned off and then back on to restore normal, Hi
power operation. A momentary switch is desired for this.

Level Mode:

 Apvoltage to the Violet wire for more than 1

sec. holds the power supply in low power mode until that voltage is
removed. A toggle switch is desired for this.

Pattern Selection Wire / WHITE (R6DX-only)

A momentary  application  of  +12VDC  (less than 1 second) to  the
WHITE  wire  will  cause  the  power  to  change  the  default  flash
pattern to the next available pattern. If the new pattern is active for
more  than  1  second,  it  will  become  the  new  default  pattern.  A
momentary  application  of  +12VDC  (more  than  1  second)  will
cause the power supply to change the default flash pattern to the
previous available pattern. If +12VDC is applied to this wire when
the unit is powered up, the default flash pattern will revert to the
factory default setting (CometFlash®).