25
Warning Tone Signal/PA Announcement Timing Information
TONE
SIGNAL
DURATION
*
1
WAIL
__ -- __ __
2
ATTACK
__ -- __ __
3
ALERT
__ -- __ __
4
PA
__ -- __ __
5
AIR HORN
__ -- __ __
6
HI/LO
__ -- __ __
7
WHOOP
__ -- __ __
8
NOON TEST
**
__ -- __ __
*
Duration is indicated as: Minutes (_) and Seconds (_ _). Unless specified otherwise by a customer, the standard
factory programming is for an event duration of three minutes (3-00), with the exception of the five-second test.
**
NOON TEST is referred to as a 5 SEC WAIL on the front panel of the ESC-864.
7.4 DIP Switch Programming
The ESC-864 controller board has two, eight-position dip switches. The switches are set by the manufacturer in
accordance with the users application and the software/hardware options that are installed into the system at the
time of manufacture. The dip switches control function settings and instant status settings. The Test Sheet, included
with each IPS, refers to these settings as Function Dips (SW 1) and Status Dips (SW 2).
Function Dips (SW 1) Programming Functions
Position
Function
Setting/Use
1
Not Used
Off
2
Decoder Format
On (10 digit)
Off (8 digit)
3
SI TEST
LED
On (30 sec clear)/Off (latch)
4
Warning Signal (Siren) Type
On (oscillating)
Off (stationary)
5
AC Battery Check
On/Off
6
Instant Response
On/Off
7
Immediate Response
On/Off
8
Master XMT
On/Off
Summary of Contents for IPS 400