background image

Page 3

IMPORTANT! When  routing  the  wires,  it  is  important  to  choose  a
path that will keep the wires away from excessive heat or any vehicle
equipment  that  could  compromise  the  integrity  of  the  wires  (ex.
trunk  lids,  door  jams,  etc.)  Before  returning  the  vehicle  to  service,
confirm  the  proper  operation  of  this  product,  as  well  as  all  vehicle
components/equipment.

Control Cable Wire Operation:

Wht/Vio: Scan-Lock™ 

(Fuse wire @ 1 AMP)

To change the flash pattern on any option, activate only that option.
TO CHANGE PATTERNS: 

To cycle forward to the next available pattern

apply  +VBAT  to  the  WHITE-VIOLET  wire  for  less  than  1  second  and
release. 

To cycle back to the previous pattern apply

 +VBAT to the WHITE-

VIOLET wire for more than 1 second and release.

TO  CHANGE  THE  DEFAULT  PATTERN: 

When  the  desired  pattern  is

displayed, allow it to run for more than 5 seconds. The lighthead will now
display this pattern when initially activated.

TO RESTORE THE FACTORY DEFAULT PATTERN: 

Turn power to the

lighthead  off.  While  applying  +VBAT  to  the  WHITE-VIOLET  wire,  turn
power to the lighthead on. The factory default pattern is now displayed. 

Use a Normally Open Momentary Switch for Scan-Lock™ operation.

Orange: Cruise 

(Fuse wire @ 7.5 AMPS)

ApVBAT to the ORG wire activates all four corner rotators at low
intensity with no flash. Choose from 4 light intensities using Scan-Lock™.

Violet: Low Power 

(Fuse wire @ 1 AMP)

Switch type is dependant on how the operator wishes Hi/Low to function:

Latching  Mode:

 Apply  +VBAT  to  the  VIO  wire  for  less  than  1  sec.,  the

power supply is “latched” into low power. The unit must be turned off and
then back on to restore normal operation. (Momentary switch)

Level  Mode:

 Apply  +VBAT  to  the  VIO  wire  for  over  1  sec.  The  power

supply stays in low power mode until voltage is removed. (Toggle Switch)

Wht/Brn: Corner Rotators 

(Fuse wire @ 15 AMPS)

ApVBAT to the WHT/BRN wire activates Corner Rotators. 

th

e

Wht/Red: LED Rotator Option #1 

(Fuse wire @ 7.5 AMPS)

 

ApVBAT to the WHT/RED wire activates Option #1.

 I

nbo

ard

Wht/Org: LED Rotator Option #2 

(Fuse wire @ 7.5 AMPS)

 

ApVBAT to the WHT/ORG wire activates Option #2.

Wht/Yel: LED Rotator Option #3 

(Fuse wire @ 7.5 AMPS)

ApVBAT to the WHT/YEL wire activates Option #2.

White: Driver Side Alley Light 

(Fuse wire @ 3 AMPS)

ApVBAT to the WHT wire activates Driver Side Alley.

Yellow: Passenger Side Alley Light 

(Fuse wire @ 3 AMPS)

ApVBAT to the YEL wire activates Passenger Side Alley

Wht/Blk: Take Downs 

(Fuse wire @ 5 AMPS)

ApVBAT to the WHT/BLK wire activates Take Downs.

Green: Front Flashers 

(Fuse wire @ 7.5 AMPS)

ApVBAT to the GREEN wire activates Front Flashers.

Blue: Rear Flashers 

(Fuse wire @ 7.5 AMPS)

ApVBAT to the BLUE wire activates Rear Flashers.

NOTE: Rotator Options #1, #2 and #3 can run up to two rotators each.

WARNING!  All customer supplied wires that connect to the positive
terminal of the battery must be sized to supply at least 125% of the
maximum operating  current and  FUSED  at  the battery  to carry  that
load. DO NOT USE CIRCUIT BREAKERS WITH THIS PRODUCT!

Ground Cable:

 

Black: Ground Wire / Extend to ground.

ROTATOR

(clockwise shown)

ROTATOR counterclockwise

starts on the opposite side and travels in the opposite direction.

ROTATOR

flash patterns operate as shown. You can change the pattern speed and direction (75 or 150 FPM) (clockwise or counterclockwise).

In patterns 9 - 14 each LED panel will flash in ModuFlash, DoubleFlash or QuadFlash.

WIGWAG

flash  patterns  operate as shown. The difference in available

flash patterns is the speed

WIGWAG

the pattern cycles (75 or 150 FPM).

is the same except after each sweep there is a delay before the pattern sweeps back simulating the light going around a full beacon.

Center WIGWAG

1

STARTS
H E R E

2

STARTS
H E R E

3

STARTS
H E R E

2

STARTS
H E R E

WIGWAG

1

STARTS
H E R E

3

STARTS
H E R E

Rotator

Rotator 75

Rotator 150

Rotator 150

WigWag 75

WigWag 150

Center WigWag 75

Center WigWag 150

Rotator ModuFlash™

Rotator ModuFlash™

75

PATTERN

#

DIRECTION

Counter Clockwise

Clockwise

Counter Clockwise

Clockwise

N/A

N/A

N/A

N/A

Counter Clockwise

Clockwise

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

Flash Patterns:

WHT/BRN

-

Corner Rotators

WHT/RED

-

LED Rotator Option 1

WHT/ORG

-

LED Rotator Option 2

WHT/YEL

-

LED Rotator Option 3

VIOLET

-

Low Power

GREEN

-

Front Flashers

BLUE

-

Rear Flashers

WHT/BLK

-

Take Downs

YELLOW

-

Passenger Alley

WHITE

-

Driver Alley

8 GA.

- (-) GROUND

BLACK

All fuses &
s w i t c h e s
customer
supplied

BATTERY

FUSE

SP/ST

7.5 AMP

SP/ST

SWITCH

15 AMP

SP/ST

7.5 AMP

SP/ST

7.5 AMP

SP/ST

1 AMP

SP/ST

7.5 AMP

SP/ST

7.5 AMP

SP/ST

5 AMP

SP/ST

3 AMP

SP/ST

3 AMP

WHT/VIO

-

ScanLock

Freedom™ Rota-Beam™ Lightbar

ORANGE

-

Cruise

SP/ST

1 AMP

Summary of Contents for Freedom HC Rota-Beam Series

Page 1: ...ing which can cause personal injury and or vehicle damage including fire Many electronic devices used in emergency vehicles can create or be affected by electromagnetic interference Therefore after installation of any electronic device it is necessary to test all electronic equipment simultaneously to insure that they operate free of interference from other components within the vehicle Never powe...

Page 2: ...to the vehicle using the supplied hardware Strap Mounting 1 Locate the mounting foot anchor plate and locking plate Loosely install the locking plate onto the mounting foot using the allen set screws Fig 5 2 Flip the lightbar upside down install an anchor plate onto the extrusion and place a mounting foot onto the extrusion Fig 2 Rotate the foot 90 counter clockwise Fig 3 so that both sides slide ...

Page 3: ...ption 2 White Driver Side Alley Light Fuse wire 3 AMPS Applying VBAT to the WHT wire activates Driver Side Alley Yellow Passenger Side Alley Light Fuse wire 3 AMPS Applying VBAT to the YEL wire activates Passenger Side Alley Wht Blk Take Downs Fuse wire 5 AMPS Applying VBAT to the WHT BLK wire activates Take Downs Green Front Flashers Fuse wire 7 5 AMPS Applying VBAT to the GREEN wire activates Fr...

Page 4: ...A BEAM 72 2 2 2 1 1 1 2 4 1 1 1 1 1 1 1 A R 22 20 1 2 2 2 28 BRACKET SPACER 07 242815 000 4 4 BASE EXTRUSION 67 25 30 31 32 33 34 35 36 37 38 39 29 40 41 49 50 51 52 53 54 55 56 57 58 42 43 44 45 46 47 48 59 60 61 8 14 104286 16JB 8 8 68 1183369 30 ENDCAP CLEAR 10 24 x 1 1 4 TX PHD SCREW W SHLDR 8 8 1 1 1 8 10 0523067 02 02 0341448 30 LABEL MODEL SERIAL NO LENS DIVIDER ASS Y CLEAR GASKET ENDCAP ED...