Page 2

DRIVER SIDE

EXAMPLE:
Two, 2-light Dominators™ mounted on the rear deck.

Phase 1 / ALT

Phase 2 / ALT

Phase 1 / SIM

Phase 2 / SIM

PASSENGER SIDE

Phase 1 / ALT

Phase 1 / SIM

Phase 1 / SIM

Phase 1 / ALT

GRY (SYNC)

WHT/VIO (Scan-Lock)

BLK (Ground)

BLK (Ground)

RED (+12VDC/Fuse @ 5A)

RED (+12VDC/Fuse @ 5A)

WHT/VIO (Scan-Lock)

GRY (SYNC)

Butt Splice

Specifications:

Input Voltage:

12.8 VDC +/- 20%

Input Current - Sim:

Peak - 3.2 Amps (Avg.: 1.28 Amps)

Input Current - Alt:

Peak - 1.6 Amps (Avg.: 0.64 Amps)

Input Sync:

Active Low

Sync Phase:

Phase I & II @ 400ms

Input Scan-Lock™:

+12 VDC @ 20 ma

Installation:

 

IMPORTANT! The lightbar should be located a minimum of
16" from any radio antennas!

Note: When
routing the wires,
it 

is 

very

important 

that

you  choose  a
path 

that 

will

keep  the  wires
away 

from

excessive heat or
any 

vehicle

equipment 

that

could
compromise  the  integrity  of  the  wires  (ex.  trunk  lids,  door  jams,
etc.).

1.

Position the unit in its proposed mounting location. Draw a pencil
line  onto  the  mounting  surface  along  the  top  and  bottom  of  the
extrusion and a “centerline” centered between the two. 

2.

Two 1/4” holes are required to mount this unit. These holes may
be located anywhere along the horizontal centerline that you drew
in step one. It’s best to locate the holes as far apart as possible.
Mark the hole location onto the mounting surface.

3.

Using a 1/4” drill bit, drill a hole in each of the areas scribed in the
previous step.

4.

Slide the 2 carriage bolts (installed in the rear of the bar) over to
the 2 mounting holes, install the rubber gaskets onto the bolts then
insert them into the mounting holes.

5.

Secure the unit by threading the flat washer and elastic stop nut
onto each bolt and tightening them firmly.

Wiring:

 

Refer to the wiring diagram on the next page.

WARNING: All customer supplied wires that connect  to  the  posi-
tive terminal of the battery must be sized to supply at least 125%
of  the  maximum  operating  current  and  FUSED  at  the    battery  to
carry  that  load.  DO  NOT  USE  CIRCUIT  BREAKERS  WITH  THIS
PRODUCT!

Operation: White/Violet / Scan-Lock™

Scan-Lock  allows  you  to  choose  from  several  flash  patterns.  To

change a flash pattern, turn on the desired lighthead:

 

CYCLE  THROUGH  ALL  PATTERNS:  To  cycle  forward,

  apply  +12

volts to the WHITE/VIOLET wire for less than 1 second and release.

 To

cycle backward,

 apply +12 volts to the WHITE/VIOLET wire for more

than 1 second and release.

SET  A  PATTERN  AS  DEFAULT: 

When  the  desired  pattern  is  displayed,

allow it to run for more than 5 seconds. The lighthead will now display this
pattern when active.

RESET TO THE FACTORY DEFAULT PATTERN: 

Turn off power and apply

+12 volts to the WHITE/VIOLET wire while turning power back on.

Note: If you wish to connect the pattern selection wire (WHITE/ VIOLET)
to a switch, an SPST momentary switch is recommended.

Available Scan-Lock™ Flash Patterns:

4, 6 & 8 Lamp Arrays: 

SignalAlert™ 75 > CometFlash® 75 > SingleFlash

375 > SingleFlash 75 > ActionFlash™ > ModuFlash™ > ZigZag 60 > ZigZag
90 ZigZag 120 > ActionScan™

2  Lamp  Array: 

Signal  Alert™  75  >  CometFlash®  75  >  SingleFlash  375

SingleFlash 75 > ActionFlash™ > ModuFlash™ > ActionScan™

Grey / SYNC:

As  an  example, we  will  synchronize two 2  lighthead Dominators™. The  2-
lighthead  Dominator™  has  4  unique  modes  for  each  of  the  4  flash
patterns that can be synchronized; Alternating Phase 1, Alternating Phase 2,
Simultaneous Phase 1 and Simultaneous Phase 2.

In Alternating Mode:

 The left lightbar alternates with the right lightbar.

In Simultaneous Mode:

 The left and right lightbars flash simultaneously.

End view of extrusion with endcap removed.

MOUNTING
SURFACE
#10 .631 DIA. X .060

FLAT WASHER

#10-24

ELASTIC

STOP NUT

DISK GASKET

BASE

EXTRUSION

Synchronized  lightbars,  must  be  set  to  the  same  pattern.  Not  all
patterns can be synchronized. Below are patterns available for SYNC.

Available Sync Patterns

Pattern Sequence

4, 6 & 8 Lamp Arrays

SignalAlert™ 75  ................. Alt. - In-Out - Checker Board - Sim. Phase I - Sim. Phase II
CometFlash® 75 ............... Alt. - In-Out - Checker Board - Sim. - Phase I - Sim. Phase II
SingleFlash 375 ................ Alt. - In-Out - Checker Board - Sim. - Phase I - Sim. Phase II
SingleFlash 75 .................. Alt. - In-Out - Checker Board - Sim. - Phase I - Sim. Phase II

2 Lamp Array:

SignalAlert™ 75 ..............  Alternating - Simultaneous - Phase I - Simultaneous Phase II

CometFlash® 75 .............. Alternating - Simultaneous - Phase I - Simultaneous Phase II

SingleFlash 375 ............... Alternating - Simultaneous - Phase I - Simultaneous Phase II

SingleFlash 75 ................. Alternating - Simultaneous - Phase I - Simultaneous Phase II

Wiring

Reviews: