Wheelock POWERPATH series PS-12-24-8CP Manual Download Page 3

Model

Order

Code

Non-

Sync

Sync w/ SM, DSM

or PS-12/24-8MP

Strobe cd

@ -31°F 

(-35°C)

Strobe cd 

@ 77°F 

(25°C)

dBA

Input

Voltage

Outdoor

Mounting 

Options*

Speaker/Strobe

ET70WP-2475W-FR

9077

Yes

Yes

75cd

*180cd

77-93

24

M

ET70WP-2475C-FR

4452

Yes

Yes

75cd

*180cd

77-93

24

M

ET70WP-2475C-FW

4454

Yes

Yes

75cd

*180cd

77-93

24

M

Back Boxes

U

SE

 W

ITH

IOB-R

5046

ET70WP-2475W-FR

N/A

N/A

N/A

N/A

N/A

Sync Modules and Power Supply

SM-12/24-R

6369

 No

Yes

N/A

N/A

N/A

12 or 24 

VDC

W

DSM-12/24-R

6374

No

Yes

N/A

N/A

N/A

12 or 24 

VDC

W

PS-12/24-8MP

3046

Yes

Yes

N/A

N/A

N/A

120/220 

VAC

N/A

PS-12/24-8CP

3047

Yes

Yes

N/A

N/A

N/A

120/220 

VAC

N/A

SPECIFICATIONS AND ORDERING INFORMATION

WARNING:  CONTACT WHEE

L

OCK FOR THE C

U

RRENT “INSTA

LL

ATION INSTR

U

CTIONS” SHEET P84149 AND 

“GENERA

L

 INFORMATION” SHEET (P82380) ON THIS PROD

U

CTS.  THESE DOC

U

MENTS 

U

NDERGO PERIODIC 

CHANGES.  IT IS IMPORTANT THAT YO

U

 HAVE C

U

RRENT INFORMATION ON THESE 

PROD

U

CTS.  THESE MATERIA

L

S CONTAIN IMPORTANT INFORMATION THAT SHO

UL

D BE READ PRIOR 

TO SPECIFYING OR INSTA

LL

ING THESE PROD

U

CTS, INC

LU

DING:

 TOTA

L

 C

U

RRENT REQ

U

IRED BY A

LL

 APP

L

IANCES CONNECTED TO SYSTEM SECONDARY POWER    

 SO

U

RCES.

 

F

U

SE RATINGS ON NOTIFICATION APP

L

IANCE CIRC

U

ITS TO HAND

L

E PEAK C

U

RRENTS FROM A

LL

    

 APP

L

IANCES ON THOSE CIRC

U

ITS.

 ADDING, 

REP

L

ACING OR CHANGING APP

L

IANCES WI

LL

 EFFECT C

U

RRENT DRAW.  RECA

L

C

UL

ATE   

 

C

U

RRENT DRAW TO INS

U

RE THAT THE TOTA

L

 AVERAGE C

U

RRENT AND TOTA

L

 PEAK REQ

U

IRED BY  

 

A

LL

 APP

L

IANCES DO NOT EXCEED THE RATED CAPACITY OF THE POWER SO

U

RCE OR F

U

SES

 COMPOSITE 

F

L

ASH RATE FROM M

UL

TIP

L

E STROBES WITHIN A PERSON’S FIE

L

D OF VIEW.

 THE 

VO

L

TAGE APP

L

IED TO THESE PROD

U

CTS M

U

ST BE WITHIN THEIR “REG

UL

ATED VO

L

TAGE  

 

 RANGE”.

 

U

SE STROBES ON

L

Y ON CIRC

U

ITS WITH CONTIN

U

O

U

S

L

Y APP

L

IED OPERATING VO

L

TAGE.  DO NOT   

 

U

SE STROBES ON CODED OR INTERR

U

PTED CIRC

U

ITS IN WHICH THE APP

L

IED VO

L

TAGE IS CYC

L

ED  

 

ON AND OFF AS THE STROBE MAY NOT F

L

ASH.

 FAI

LU

RE TO COMP

L

Y WITH THE INSTA

LL

ATION INSTR

U

CTIONS OR GENERA

L

 INFORMATION  

 

 SHEETS 

CO

UL

D RES

UL

T IN IMPROPER INSTA

LL

ATION, APP

L

ICATION, AND/OR OPERATION OF THESE  

 PROD

U

CTS IN AN EMERGENCY SIT

U

ATION, WHICH CO

UL

D RES

UL

T IN PROPERTY DAMAGE AND  

 

 SERIO

U

S INJ

U

RY OR DEATH TO YO

U

 AND/OR OTHERS.

 

COND

U

CTOR SIZE (AWG), 

L

ENGTH AND AMPACITY SHO

UL

D BE TAKEN INTO CONSIDERATION 

 

PRIOR TO DESIGN AND INSTA

LL

ATION OF THESE PROD

U

CTS, PARTIC

UL

AR

L

Y IN RETROFIT 

 INSTA

LL

ATIONS.

N/A = Not applicable

*Per UL 1638 @ 78°F (75cd @ -31°F).

Reviews: