background image

P83862 M 

 

  Sheet 20 of 23 

 

Example 16:  Synchronized Multiple PS-12/24-8 Using a Master PS-12/24-8 (in the WHEELOCK SYNC 
MODE) With Audible Silence, and Using Input #1. 

absolutely 

OUT1

OUT2

OUT3

OUT4

FAULT

INP1 INP2

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

OUT1

OUT2

OUT3

OUT4

INPUT SELECT

TEMPORAL

STROBE SYNC

IN>OUT SYNC

INPUT SELECT

TEMPORAL

STROBE SYNC

IN>OUT SYNC

AUX

DC

NO "REMOTE" C

AUX

RESET

+

_

+

_

+

_

+

_

+

_

+

_

OUT1

OUT2

OUT3

OUT4

IN1

IN1

IN2

IN2

RET1

RET1

RET2

RET2

+

_

+

_

+

_

+

_

C  "DRY1"  NC

C  "DRY2"  NC

UPPER
LOWER

NC

C

NO

C "F

AU

LT

" NC

ON OFF

ON OFF

SW1

SW2

OUT1

OUT2

OUT3

OUT4

FAULT

INP1

INP2

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

OUT1

OUT2

OUT3

OUT4

INPUT SELECT

TEMPORAL

STROBE SYNC

IN>OUT SYNC

INPUT SELECT

TEMPORAL

STROBE SYNC

IN>OUT SYNC

AUX

DC

NO "REMOTE" C

AUX

RESET

+

_

+

_

+

_

+

_

+

_

+

_

OUT1

OUT2

OUT3

OUT4

IN1

IN1

IN2

IN2

RET1

RET1

RET2

RET2

+

_

+

_

+

_

+

_

C  "DRY1"  NC

C  "DRY2"  NC

UPPER
LOWER

NC

C

NO

C "F

AU

LT

" N

C

ON OFF

ON OFF

SW1

SW2

OUT1

OUT2

OUT3

OUT4

FAULT

INP1 INP2

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

1

2

3

4

ON

OUT1

OUT2

OUT3

OUT4

INPUT SELECT

TEMPORAL

STROBE SYNC

IN>OUT SYNC

INPUT SELECT

TEMPORAL

STROBE SYNC

IN>OUT SYNC

AUX

DC

NO "REMOTE" C

AUX

RESET

+

_

+

_

+

_

+

_

+

_

+

_

OUT1

OUT2

OUT3

OUT4

IN1

IN1

IN2

IN2

RET1

RET1

RET2

RET2

+

_

+

_

+

_

+

_

C  "DRY1"  NC

C  "DRY2"  NC

UPPER
LOWER

NC

C

NO

C "F

AU

LT

" N

C

ON OFF

ON OFF

SW1

SW2

ADDITIONAL PS-12/24-8,

      APPLIACES OR

+

-

+

-

+

-

+

-

+

-

+

-

NOTE 2

NOTE 5

NOTE 5

NOTE 5

NOTE 4

NOTE 4

FACP

NAC Input in

Alarm Condition

NOTE 1

Programmed Audible

Silence NAC

-
+

FACP

EOLR

FACP

EOLR

NOTE 3

MASTER

REMOTE

REMOTE

 

 

NOTE 1

:  NAC Input Voltage 9.0 to 30.0VDC Constant. 

NOTE 2

OBSERVE DIP SWITCH SETTINGS

 

Input Selection Switch (Position 1) on OUT1 to OUT4 DIP Switches are shown in the "ON" 
Position allowing Input #1 to activate Outputs 1-4, Positions 2-4 are set for "WHEELOCK SYNC MODE" 

NOTE 3

:  Diagram shown with an output circuit (OUT4) on Master PowerPath used to synchronize the Remote PowerPaths.  In 

this configuration the Master PowerPath can only have three NAC circuits. 

NOTE 4

OBSERVE DIP SWITCH SETTINGS 

Input Selection Switch (Position 1) on OUT 1 to OUT 4 DIP Switches are shown in the "ON" Position allowing Input 
#1 to activate Outputs 1-4.  Positions 2-4 are set for "IN>OUT SYNC MODE". 

NOTE 5

:  Jumpers must be placed across  “DRY1” and “DRY2” terminals when operating Power Supply using “IN1” or “IN2”. 

 

Summary of Contents for POWERPATH PS-12-24-8

Page 1: ...TER POWER SUPPLY Installation Instructions 273 Branchport Avenue Long Branch NJ 07740 6899 Ph 800 631 2148 Fax 732 222 8707 Web Site www wheelockinc com e mail info wheelockinc com P83862 M Copyright...

Page 2: ...MOUNTING 7 2 3 WIRING 9 2 4 RELAY STATUS CONNECTIONS 10 3 0 OPERATION 11 3 1 MODES OF OPERATION 11 3 2 DIP SWITCH SETTINGS 11 3 3 CLASS B OPERATION 12 3 4 CLASS A OPERATION 15 3 5 MASTER REMOTE OPERA...

Page 3: ...power output that can be reset is provided The PS 12 24 8 also contains a battery charger capable of charging either 7 or 12 AMP Hour AH of battery backup The PS 12 24 8 can only provide a maximum loa...

Page 4: ...hat can be fed to any or all of the output circuits Input and output can be synchronized with IN OUT SYNC mode SM DSM or 2nd PS 12 24 8 is required Audible silence capability Filtered and electronical...

Page 5: ...YNC IN OUT SYNC AUX DC NO REMOTE C AUX RESET _ _ _ _ _ _ OUT1 OUT2 OUT3 OUT4 IN1 IN1 IN2 IN2 RET1 RET1 RET2 RET2 _ _ _ _ C DRY1 NC C DRY2 NC UPPER LOWER NC C NO C FAULT NC ON OFF ON OFF SW1 SW2 DC BAT...

Page 6: ...and can be individually programmed for Normal Mode Temporal Mode IN OUT SYNC Mode or WHEELOCK SYNC Mode The outputs can be configured as four Class B circuits two Class A circuits or two Class B and o...

Page 7: ...T INP1 INP2 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON OUT1 OUT2 OUT3 OUT4 INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC AUX DC NO REMOTE C AUX RESET _ _...

Page 8: ...NPACKING The POWERPATH was carefully checked before leaving the factory Inspect shipping container and unit carefully for indications of improper handling If damage is detected make an immediate claim...

Page 9: ...P83862 M Sheet 8 of 23 Figure 3 Mounting Dimensions BOTTOM FRONT RIGHT TOP VIEW SIDE SIDE LEFT NOTE All dimensions shown are measured in inches...

Page 10: ...2 Value is determined by FACP F Connect desired auxiliary equipment to the auxiliary output terminals AUX CAUTION For the Ground Fault Detection Circuit to operate the 22K OHM RESISTOR WIRE ASSEMBLY m...

Page 11: ...n and the C NO will short after 1 minute or 6 hours depending on the condition of J1 J1 in line 1 minute J1 removed 6 hours Refer to Figure 4 LOGIC BOARD COMMON TROUBLE TERMINALS The common trouble te...

Page 12: ...ut to be utilized by the POWERPATH These appliances may come from a FACP another PS 12 24 8 or a Wheelock Synchronization Module SM 12 24 or DSM 12 24 Audibles can also be silenced WHEELOCK SYNC MODE...

Page 13: ...PORAL STROBE SYNC IN OUT SYNC OR EOLR 2 2K OHMS LOGIC BOARD SWI OPEN SW2 OPEN TO NEXT APPLIANCE OR EOLR IN1 RET1 OUT1 A P C F TO NEXT APPLIANCE OR EOLR 2 2K OHMS TO NEXT APPLIANCE OUT2 TO NEXT APPLIAN...

Page 14: ...MODE with a coded input source A second constant input with a second output set in the NORMAL MODE will provide the constant voltage CAUTION Only use audible appliances that can use a coded signal Do...

Page 15: ...with Wheelock sync appliances Example 6 WHEELOCK SYNC MODE without Audible Silence CLASS B POWERPATH 1 2 3 4 ON OUT1 4 INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC LOGIC BOARD SWI OPEN SW2 OPEN IN1...

Page 16: ...OUT2 and OUT4 When operating in Class A the two circuits must have the same switch settings for the operational mode selected Switches SW1 and SW2 on the logic board are in the CLOSED position IN1 and...

Page 17: ...or NS NS4 NH appliances with TEMPORAL MODE Example 10 IN OUT SYNC MODE from CODED INPUT SOURCE CLASS A POWERPATH LOGIC BOARD SWI CLOSED SW2 CLOSED 1 2 3 4 O N 1 2 3 4 O N OUT1 OUT3 INPUT SELECT TEMPO...

Page 18: ...Wheelock external Sync Module SM or DSM synchronization will only occur with Wheelock sync appliances Example 12 IN OUT SYNC MODE with External Sync Module with Audible Silence CLASS A POWERPATH LOGIC...

Page 19: ...1 4 INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC OUT4 OUT2 OUT3 OUT1 RET2 IN2 IN1 AUDIBLE SILENCE RET1 A F P C OR EOLR OR RETURN TO FACP CLASS A TO NEXT APPLIANCE TO NEXT APPLIANCE CLASS A TO FACP OR...

Page 20: ...OUT SYNC INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC AUX DC NO REMOTE C AUX RESET _ _ _ _ _ _ OUT1 OUT2 OUT3 OUT4 IN1 IN1 IN2 IN2 RET1 RET1 RET2 RET2 _ _ _ _ C DRY1 NC C DRY2 NC UPPER LOWER NC C NO...

Page 21: ...TEMPORAL STROBE SYNC IN OUT SYNC INPUT SELECT TEMPORAL STROBE SYNC IN OUT SYNC AUX DC NO REMOTE C AUX RESET _ _ _ _ _ _ OUT1 OUT2 OUT3 OUT4 IN1 IN1 IN2 IN2 RET1 RET1 RET2 RET2 _ _ _ _ C DRY1 NC C DRY...

Page 22: ...le C FAULT NC terminals OPEN Check inputs If LED s INP1 or INP2 flashing Check outputs if LED s OUT1 OUT2 OUT3 OUT4 flashing Check circuit connected to C FAULT NC terminals AC LED OFF No AC power inpu...

Page 23: ...W RSS 24110W RSS 2415C RSS 2430C RSS 2475C RSS 24100C RSS 24MCW APPLIANCES WITH SYNCHRONIZING STROBES MT 24 SLM CH70 24MCW CH70 2415W CH70 241575W CH70 2430W CH70 2475W CH70 24110W CH70 24MCW CH90 241...

Page 24: ...INING WHETHER A PRODUCT IS SUITABLE FOR THE USER S PURPOSES OR WHETHER IT WILL ACHIEVE THE USER S INTENDED RESULTS THERE IS NO WARRANTY AGAINST DAMAGE RESULTING FROM MISAPPLICATION IMPROPER SPECIFICAT...

Reviews: