background image

47xxN Series Time Zone Display 

Operating and Installation Instructions

 

1 - Introduction 

The 47xxN series time zone displays provide a precise and elegant display of time using red, green, 
yellow/amber, blue or white LED display characters with an unrivalled flexibility of operation in the most 
demanding timekeeping and stopwatch applications.  
All units can be used in stand-alone applications, while 47xxN products are primarily intended to be 
synchronised via NTP/SNTP from a remote time server located on the customers TCP/IP Ethernet network. 
In addition, 47xxN units can be configured for over 30 different types of secondary clock operation, 
included GPS, MSF or DCF radio time code synchronisation when used with the appropriate option module 
or radio receiver.. 
The 47xxN series time zone displays can display static time display; alternating time and date or alternating 
time and temperature; or alternating time, date and temperature. (Please note, temperature display only 
available on 47xxN series units and requires connection of 406 temperature sensor.) 
All of the digital clocks also have the ability to operate as a multi-range programmable stopwatch using 
supplied infrared remote control or using an external stopwatch control panel or user supplied voltage free 
contact closure or switch. 

Simple Operation 

All 47xxN series time zone displays are supplied with an infrared remote control to allow for easy setup 
and control of stopwatch functions.  The units are simple to configure and will automatically adjust 
themselves for seasonal daylight savings time changes (as required). 

Operating Features 

The 47xxN series time zone displays offer the following operating features. 

83 preset location codes - The digital clock may be user programmed to display the time in one 
of 83 different preset locations. 

User programmable time zone - To allow for custom time zones or future changes in legislation  

Automatic or manual brightness - The display may be programmed to one of seven preset 
display brightness levels.  Alternatively, the unit may be programmed for automatic display 
brightness where the display illumination level is reduced as the ambient light level decreases -  

Multi-function Stopwatch - The display can be configured to operate as a count-up or 
count-down stopwatch with a the display freely switchable between operating modes or fixed 
to either stopwatch or clock display. 

 
 
 

 

 

 

3

 Issue 2.1 

Summary of Contents for 47 N Series

Page 1: ...tup Page 7 6 Network Setup Page 10 7 Synchronisation Setup Page 11 8a Display Setup 472xN and 474xN series Page 14 8b Calendar Setup 470xN and 475xN series Page 15 9 Stopwatch Setup Page 16 10 Externa...

Page 2: ...ts for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The equipment...

Page 3: ...bility to operate as a multi range programmable stopwatch using supplied infrared remote control or using an external stopwatch control panel or user supplied voltage free contact closure or switch Si...

Page 4: ...e performed in accordance with current Building Regulations and the Seventeenth Edition of the IEE Wiring Regulations or equivalent local standard The power supply is fitted with an internal fuse In c...

Page 5: ...ove next setting Function Location Setting Mode See page 5 1 Press Up to enter Location Setting Mode or press to move to next setting Function Synchronisation Setting Mode See page 6 1 Press Up to ent...

Page 6: ...ess to increment seconds to set to zero Press Up to set minutes count Minutes Setting Mode Press or to increment or decrement minutes Press Up to set the hours count Complete time setting process deta...

Page 7: ...gs are accessed from the function menu as detailed in section 3 Each time display can be independently configured to display a different world time The 47xxNIL series units have illuminated location l...

Page 8: ...Aviv 2 Yes 07 MSK 1 Russia Kaliningrad 3 No 08 UTC 3 CHARLIE AST Iraq Baghdad S Arabia Riyadh 3 No 09 MSK Russia Moscow 4 No 10 IRST IRDT Iran Tehran 3 Yes 11 UTC 4 DELTA GST UAE Dubai Abu Dhabi 4 No...

Page 9: ...T WGST Greenland West Nuuk 3 Yes 65 PMST PMDT US Pierre Miquelon 3 Yes 66 UYT UYST Uruguay Montevideo 3 Yes 67 UTC 2 5 2 1 2 No 68 UTC 2 OSCAR 2 No 69 UTC 1 NOVEMBER CVT Cape Verdi Praia 1 No 70 AZOT...

Page 10: ...eway by customers DHCP server User setting of NTP server addresses Exit to Time display dh No Static assignment of IP Subnet and Gateway addresses by user User setting of NTP server addresses Select I...

Page 11: ...r existing 5200 or 4860 series master clock 482 w482 Time code from existing 5200 4860 or 482D series master clock Zo 1 F w482 time code zone that unit will use for synchronisation DCF DCF77 Radio tim...

Page 12: ...w DHCP and the Up arrow should be pressed again to return to the time display If clock is to DHCP or Static modes the 4 bytes of the first NTP time server address can be programmed in same manner as d...

Page 13: ...CF or MSF radio time code when connected to either the 484 02 MSF Radio Receiver or 484 03 DCF Radio Receiver supplied separately as follows Clock configuration 1 Press Menu or Up button to access clo...

Page 14: ...Display Style ti Standard time display Exit to Time display gb Alternating time and date in ddmm format Display hold time us Alternating time and date in mmdd format Display hold time eu Alternating t...

Page 15: ...as per language table below Calendar 2 Mode Calendar 2 Mode M2 xx As mode settings for Calendar 1 above Calendar 2 Lang Calendar 2 Language C2 xx Calendar 2 Language as per language table below Calen...

Page 16: ...grammed start time stop at zero Select hold mode SA 03 Down from pre programmed start time then up from zero Select hold mode SA 04 Down from pre programmed start time automatically restart countdown...

Page 17: ...settings Exit to time display Tc nt Et Tc nt Display continuous temperature display See 406 documentation for further settings Exit to time display Lo cl Et Lo cl Enable Local Master synchronisation o...

Reviews: