background image

POWER AMPLIFIER

PLEASE READ IMPORTANT INSTRUCTIONS 

BEFORE USING THE AMPLIFIERS! SAFETY 

INSTRUCTIONS

To reduce the risk of electric shock the user should 
not remove the cover. All operating and safety 
instructions should be fillowed. The unit should be 
kept clear of water, fluids and moisture and not be 
operated in damp conditions. The unit should be 
operated in a well ventilated environment. The unit 
should be kept away from excessive heat sources 
such as radiators and if racked with other power 
amplifiers there should be a free air flow to vent 
out the heat produced check with (dealer). The 
unit must only be connected to a power supply as 
shown on the rear of the unit with the IEC cable (or 
similar) provided with precaution taken to make 
sure that the grounding (earthing) or prolarisation 
is  in  place  and  not  in  defeat  mode  (ie.  Earth 
disconnected). The power cord must be situated 
or routed so as not to be walked upon or pinched 
or objects placed upon it with special attention to 
the area where the power cable enters the unit. 
The power cable should be disconnected during 
prolonged non usage. The user should not attempt 
to service the unit or do anything to the unit except 
those things described in this manual. For service 
and repair your dealer should be contacted. This 
unit complies with the relevant safety regulations.

POWER NOTICE FOR SAFETY

All british and European countries have a nominal 
230v  mains  power  supply  which  in  practice  is 
between  220V  and  240V.  In  the  USA  the  main 
power supply is nominally 115V and in Japan 100V. 
This unit is factory set to the correct voltage and 
this can be checked by looking at the label on the 
rear panel near the power cable. If the unit is to 
be used in a country other than that if was shipped 
to consult your dealer. The unit is suitable for use 
with mains frequencies of 50-60Hz. As there are no 
user serviceable components inside the amplifier, 
and high voltages are present, DO NOT remove 
the covers! Be sure to make all audio connections 
to the amplifier before connecting to the mains 
supply. Do not disconnect the amplifier from the 
grounded equipment with the mains connector still 
plugged into the mains supply. Important warning! 
This Unit MustBe Grounded, Do not Disconnect the 
Ground Connection! Any sound system should be 
connected to ground at one point only. If there is 

more than one Connection to earth, a GROUND 
LOOP can be formed, which allows mains hum to 
enter the circuitry, sometimes at a high level. If hum 
occurs in the system consult your dealer.

APPLICATION

The  new  Mp  range  of  power  amplifiers  from 
Wharfedale is designed to give musicians, club 
owners and DJ’s the performance, reliability and 
sound quality they require.

DESCRIPTION

The MP series consists of three models, the MP1200, 
MP1800,  MP2800.  These  power  amplifiers  are 
designed for standard 19’’ (482mm) rack mounting. 
They have power supplies with substantial heavy 
high current transformers therefore each model 
requires rear rack support to prevent stress on the 
front panel. These amplifiers are housed in steel 
casing  suitable  for  racking  in  professional  flight 
cases.

OPERATING

Before switching on the power amplifier ensure 
that ALL audio inputs are connected, ALL speaker 
cables  are  securely  connected,  ALL  volume 
controls on the front panel are fully off and that 
the mains connections are safely and fully off and 
that the mains connections are safely and securely 
connected at the supply and amplifier unit.

CLASS 3 WIRING

 

Class  3  Wiring  for  TERMINALS  with  a  measured 
open-circuit  voltage  exceeding  120V  r.m.s.  but 
not exceeding 300 V r.m.s. when delivering NON-
CLIPPED OUTPUT POWER.

FOR COMMERCIAL PURPOSE ONLY.

Summary of Contents for MP 2800

Page 1: ...Power Amplifier Operating Manual 使 用 说 明 书 Operating Manual ...

Page 2: ... objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Do not install this equipment on the far position from wall outlet and or convenience receptacle Do not install this equipment in a confined space such as a box for the conveyance or similar unit Use only with the cart stand tripod bracket or table specified by t...

Page 3: ... the strong steel case through the thick multi layer circuit boards to the array of power transistors Wharfedale have built in a healthy safety margin Modern manufacturing techniques and value engineered design Unpacking A l l W h a r f e d a l e P r o products are fully checked before leaving the factory After unpacking please inspect contents for any physical damage Please retain the shipping ca...

Page 4: ...her than that if was shipped to consult your dealer The unit is suitable for use with mains frequencies of 50 60Hz As there are no user serviceable components inside the amplifier and high voltages are present DO NOT remove the covers Be sure to make all audio connections to the amplifier before connecting to the mains supply Do not disconnect the amplifier from the grounded equipment with the mai...

Page 5: ... DC voltage Is present at the amplifier outputs 4 BRIDGE ON INDICATOR When the rear panel s STEREO BRIDGE switch be placed in BRIDGE Then the front panel s BRIDGE indicator will be bright 5 PEAK INDICATORS PEAK indicator on each channel illuminates when distortion reaches or exceeds approximately 1 6 INPUT ATTENUATORS Separate level controls are provided for channel one and channel two input clock...

Page 6: ...NO OPERATION To obtain a higher power output into a loudspeaker load the two stereo channels may be bridged to form one Mono channel To do this connect the positive speaker wire to the RED post on channel A and the negative speaker wire to the RED post on channel B Alternatively the bridge Speakon can be used the pin configuration is 1 positive 1 negative When in this mode the BRIDGE switch on the...

Page 7: ...nected at both Please note that some manufacturers run their units with pin 2 cold and pin 3 hot This should be looked out for and then the wiring could be modified with labeled cables so that connections of hot go to their corresponding hot etc Some manufactures run their units with balanced inputs and unbalanced outputs therefore care should be taken with the connections when inserted into the s...

Page 8: ...H1 CH2 gain knobs Stereo Bridge mode switch Power switch on off mute Short circuit Open circuit Thermal VARIABLE SPEED FAN 23kg 50 6lbs 21 5kg 47 3lbs 133 x 483 x 355 5 2 x 19 x 13 9 76dB 100dB less than 0 05 20Hz to 20kHz 5Hz to 50kHz Greater than 300 Class AB XLR 1 4 TRS 5 WAY BINDING POSTS SPEAKON OR SPEAKON AC Switch CH1 CH2 gain knobs Stereo Bridge mode switch Power switch on off mute Short c...

Reviews: