background image

Note:

Annually at the end of the season, fully drain all water in the pipework and pump chamber. Whale® cannot

guarantee warranty if the system is not fully drained for winterising.

Service kits available: AK3706 and AK3714
For installation or service advice please contact Whale® Customer Support:

Tel: +44 (0)28 9127 0531 
Email: [email protected]  
www.whalepumps.com

This product complies with all relevant European directives and standards. Please contact Whale® if further details
are required

Manufacturer’s Declaration

We hereby declare, under our sole responsibility, that the enclosed equipment complies with the international 
standard EN ISO 15083:2003 - Small craft-bilge pumping systems. 

Engineering Director
Date: October 2016

WHALE® and GUSHER® are registered trademarks of Munster Simms Engineering Limited, Bangor, Northern
Ireland trading as Whale. 

This Whale® product is covered by a 5 year warranty. Please see the enclosed document for details of our 
Statement of Limited Warranty. 

©Copyright Whale 2017 - All rights reserved. Reproduction in whole or in part without permission is prohibited.
WHALE® is a registered trademark of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as
Whale. Whale’s policy is one of continuous improvement and we reserve the right to change specifications without
prior notice. Illustrations are for guidance purposes only. Neither the accuracy nor completeness of the information
contained in any Product brochure is guaranteed by the Company and may be subject to change at its sole discre-
tion.

Please note that by contacting Whale Support you will be indicating your consent to receiving product updates,
recall information, help guides and appropriate marketing messages from us via post, email or telephone unless you
indicated an objection to receiving such messages.

10.

WINTERISING

9.

TROUBLE SHOOTING

13. PATENTS AND TRADEMARKS

14.

WARRANTY

Fails to prime

Inlet hose fault

Check inlet hose connection is airtight, free from blockages and does not 
collapse during suction stroke

Diaphragm failure

If damaged replace all rubber parts (see Service kits)

Debris in the body 
of the pump

May not prevent its operation but should be removed to prevent 
damage

Inlet and/or
outlet valve failure

Inspect and remove any debris. If damaged replace (see Service kits)

USA Tel: 1 802 367 1091
USA Fax: 1 802 367 1095
Email USA: [email protected]
www.whalepumps.com

11. 

SERVICE SUPPORT DETAILS

12.

DECLARATION OF CONFORMITY, STANDARDS AND APPROVALS

6

Summary of Contents for Gusher 10 Mk3 BP3708

Page 1: ...g 1 Through deck installation Fig 2 Incorrect installation Fig 3 Typical installation diagram Fig 4 Mounting arrangements for a standard model Fig 5 Dimensions Fig 6 Discharge point is well above the water line Fig 7 Deck fitting for Gusher Pumps Half sectional elevation of deck fitting pump and bracket Fig 8 Exploded diagram Read the following carefully before installation To the Fitter Check tha...

Page 2: ...ion diagram Not suitable for pumping flammable liquids diesel chemicals etc Suitable for bilge water only With all applications it is important that a system of safe working practice is applied to installation use and maintenance Ensure the waste water system is drained before installation In order to securely fasten the unit ensure that the mounting surface is a minimum thickness of 18mm 45 64 as...

Page 3: ...sucking against a flat surface and allows the water level to be reduced to a minimum To minimise pumping effort site the pump halfway in height between the strumbox strainer and hull outlet Mount in a position with the shortest run lengths possible Use a reinforced hose on inlet to prevent collapsing during suction The Gusher 10 is designed for mounting on deck bulkhead BP3708 or through deck bulk...

Page 4: ...te of suitable thickness so that the backing plate plus the deck is at least the minimum thickness and no greater than 1 25mm Bond the backing plate to the deck If using Deck plate DP3804 the minimum deck thickness is 13mm 3 Position the pump under deck and check flow direction Work the rubber gaiter up through the hole until its flange rests on the deck Secure the 6 1 4 6mm countersunk mounting s...

Page 5: ...is checked annually for leaks and obstructions Optimal Performance Ensure this product is clear of debris It is recommended a service kit is kept on board These are available from your local chandlery Changing the Diaphragm and Valves 1 Slacken and remove the wormdrive clip to release the diaphragm 2 Release diaphragm nut and remove diaphragm plates and diaphragm 3 Replace old inlet and outlet val...

Page 6: ...Engineering Limited Bangor Northern Ireland trading as Whale Whale s policy is one of continuous improvement and we reserve the right to change specifications without prior notice Illustrations are for guidance purposes only Neither the accuracy nor completeness of the information contained in any Product brochure is guaranteed by the Company and may be subject to change at its sole discre tion Pl...

Page 7: ......

Page 8: ...Munster Simms Engineering Ltd 2 Enterprise Road Bangor N Ireland BT19 7TA Tel 44 0 28 9127 0531 whalepumps com info whalepumps com Ref No db_jw_G10_180 07_v3_0217 ...

Reviews: