Short-Circuit Protection

Should a short-circuit occur in the RV, the WF-8700 Series Power Center converter will 

drop the voltage output to zero volts. If the short-circuit condition is removed and no 

other fault conditions are detected, the converter will resume normal operation. However, 

short-circuit conditions are dangerous, and an RV will require inspection by a qualified 

service technician.

CIRCUIT PROTECTION
WF-8700 Series Power Center Fuses and Breakers

DC Fuses (12 Volts)

The DC fuse boards have spaces the Branch, Battery and Reverse Polarity fuses as 

described above. Should any of fuses blow, the Branch Circuit fuses and the Reverse 

Battery Protection fuses should be replaced with ATC or ATO automotive type fuses such 

as:
• 

Littelfuse type 257

• 

Bussmann type ATC

AC Circuit Breakers (120/240 Volts)

The AC Breaker side of the WF-8700 Series Power Center is located on the left side of the 

enclosure. The WF-8700 Series Power Center accepts standard residential breakers. The 

WF-8712P and WF-8725P have spaces for a 30 Amp Main and up to 3 Branch breakers 

when using duplex breakers. The WF-8735P and WF-8740P have spaces for a 30 Amp 

Main and up to 5 Branch breakers when using duplex breakers. A list of factory tested and 

approved breakers follows. The breakers may be purchased at most big-box department 

stores and home centers.

 

UL-Listed Main Circuit Breakers, Rated for 120V, Maximum 30A

The following breakers have been factory tested and approved for use as 30 Amp Main 

breakers in the WF-8700 Series Power Center:

Manufacturer

Model/Cat. No./Type

Cutler Hammer

Type BR and C

Thomas Betts

Type TB or TBBD

ITE/Siemens

Type QP or QT

Square D

Type HOM or HOMT

Murray

Type MP-T or MH-T

General Electric

Type THQL

UL-Listed Branch Circuit Breakers, Rated for 120V, Maximum 20A

The following breakers have been factory tested and approved for use as Branch breakers 

in the WF-8700 Series Power Center:

Summary of Contents for WF-8700 Series

Page 1: ...ION 877 294 8997 Warranty warranty wfcoelectronics com Fax 574 294 8698 www wfcoelectronics com Power PROs Technical Support 877 294 8997 WF 8700 Series WF 8712P WF 8725P WF 8735P WF 8740P The Power Center model number is located on the front panel label near the AC breakers ...

Page 2: ... UL Listed Main Circuit Breaker List 5 UL Listed Branch Circuit Breaker List 5 OPERATIONAL FEATURES Three Stage Smart Charging 7 TROUBLESHOOTING INSTRUCTIONS Converter Output Voltage 8 Reverse Polarity Fuses 8 Troubleshooting Flow Chart 9 GENERAL COMPLIANCE INFORMATION Agency Listings 9 INSTALLATION INSTRUCTIONS Mounting the Enclosure 10 Wiring the AC Breakers 10 Wiring the DC Fuse Board 11 SPECIF...

Page 3: ... Center converter operation When a battery is installed a reverse polarity fuse protects the converter circuitry The fuse is located along the bottom of the row of fuses Refer to Figure 1 below This feature prevents permanent damage to the converter from a battery connected into the circuit backwards In addition to protecting the converter section the reverse polarity fuse is the main connection b...

Page 4: ...overload condition Automatic Cooling Fan The cooling fan in the WF 8700 Series Power Center is incremental and is controlled by the current drawn out of the converter to the applied load NOTE The WF 8712P does not have a fan The on board microprocessor increases fan speed as the total load increases and decreases fan speed as the load decreases Unlike traditional temperature controlled fans the lo...

Page 5: ...ower Center is located on the left side of the enclosure The WF 8700 Series Power Center accepts standard residential breakers The WF 8712P and WF 8725P have spaces for a 30 Amp Main and up to 3 Branch breakers when using duplex breakers The WF 8735P and WF 8740P have spaces for a 30 Amp Main and up to 5 Branch breakers when using duplex breakers A list of factory tested and approved breakers foll...

Page 6: ...OMT Murray Type MP T or MH T General Electric Type THQL When replacing any of the installed circuit breakers the replacement should be of the same manufacturer type designation and equal interrupting rating not to exceed 30A The Short Circuit Current rating for the breaker should be 10 000 Amps Breaker Filler Plates Model FP 01 or FP 01B Black Figure 2 6 ...

Page 7: ...xceeding it If the output current reaches its maximum normally caused by a discharged battery this will cause the converter to go into Bulk Mode which means the target output voltage will change to 14 4 VDC and a timer will start Although the converter is outputting 14 4 VDC you will not be able to read that on a voltmeter due to the voltage current relationship From the paragraph above as load cu...

Page 8: ...ircuit 4 30 A WF 8735P Circuit 6 30 A WF 8740P Circuit 6 30 A Reverse Polarity Fuses If there is no DC output coming from the WF 8700 Series Power Center converter section first check the reverse polarity fuse s on the fuse board Then visually inspect the fuses for any breaks in the fuse element If no breaks are found use a continuity tester to check for continuity If the reverse polarity fuses ar...

Page 9: ...laim packet GENERAL COMPLIANCE INFORMATION Agency Listings UL The WF 8700 Series Power Centers are UL Listed and cUL Listed Canadian FCC Compliance Class B NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment...

Page 10: ...x breakers 1 Main and up to 5 Branch breakers Refer to the tables on pages 5 and 6 for a selection of approved breakers The Main breaker should be 30 Amp and is to be installed in the left most position See the wiring diagrams below A hold down clip is provided to keep the breaker securely in place The 30 Amp power cord is routed through the large knockout in the back of the wiring compartment and...

Page 11: ...ts on the WF 8712 and WF 8725 Power Centers have up to 20 Amp ATO or ATC fuses installed On the WF 8735 and WF 8740 Power Centers circuits F5 and F6 can be used for slide outs or other higher current loads and can have a maximum 30 Amp ATO or ATC fuse installed The remaining 4 circuits are general purpose and can have up to 20 Amp ATO or ATC fuses installed Make sure the fuses are seated properly ...

Page 12: ...Connect the heavy wire Red coming from the battery to the Red 10AWG wire coming from the back of the enclosure As a last step install a separate bus bar in a location behind the converter Connect the 10AWG White wire coming from the back of the enclosure to this bus bar Connect the battery negative wire to this bus bar along with all the negative DC load wires Also run a wire from the bus bar to c...

Page 13: ...t not limited to inconvenience loss of service loss of revenue loss or damage to personal property cost of all services performed in removing or replacing the WFCO product Specifications are subject to change without notice or obligation Any WFCO Electronics products sold through unauthorized Internet sources Example eBay will be excluded from all warranty coverage offered by Arterra Distribution ...

Page 14: ...14 Figure 7 ...

Page 15: ...Figure 8 15 ...

Page 16: ...W F C O E L E C T R O N I C S C O M ...

Reviews: