Short-Circuit Protection
Should a short-circuit occur in the RV, the WF-8700 Series Power Center converter will
drop the voltage output to zero volts. If the short-circuit condition is removed and no
other fault conditions are detected, the converter will resume normal operation. However,
short-circuit conditions are dangerous, and an RV will require inspection by a qualified
service technician.
CIRCUIT PROTECTION
WF-8700 Series Power Center Fuses and Breakers
DC Fuses (12 Volts)
The DC fuse boards have spaces the Branch, Battery and Reverse Polarity fuses as
described above. Should any of fuses blow, the Branch Circuit fuses and the Reverse
Battery Protection fuses should be replaced with ATC or ATO automotive type fuses such
as:
•
Littelfuse type 257
•
Bussmann type ATC
AC Circuit Breakers (120/240 Volts)
The AC Breaker side of the WF-8700 Series Power Center is located on the left side of the
enclosure. The WF-8700 Series Power Center accepts standard residential breakers. The
WF-8712P and WF-8725P have spaces for a 30 Amp Main and up to 3 Branch breakers
when using duplex breakers. The WF-8735P and WF-8740P have spaces for a 30 Amp
Main and up to 5 Branch breakers when using duplex breakers. A list of factory tested and
approved breakers follows. The breakers may be purchased at most big-box department
stores and home centers.
UL-Listed Main Circuit Breakers, Rated for 120V, Maximum 30A
The following breakers have been factory tested and approved for use as 30 Amp Main
breakers in the WF-8700 Series Power Center:
Manufacturer
Model/Cat. No./Type
Cutler Hammer
Type BR and C
Thomas Betts
Type TB or TBBD
ITE/Siemens
Type QP or QT
Square D
Type HOM or HOMT
Murray
Type MP-T or MH-T
General Electric
Type THQL
UL-Listed Branch Circuit Breakers, Rated for 120V, Maximum 20A
The following breakers have been factory tested and approved for use as Branch breakers
in the WF-8700 Series Power Center: