- 8-73 -
8.2.5
8.3
Maintenance
8.3.1 Non-Lube Pneumatic System Maintenance
A coalescing-type mist separator that effectively removes 99.9% of oil mist from incoming air.
Combined with pre-lubricated air cylinders and valves, this provides reliable pneumatic operation.
Maintenance
•
Drain the mist separator bowl frequently.
•
As the mist separator becomes contaminated, the pressure drop across the filter will
increase. Replace the element when the pressure drop reaches 15 PSI, or once per year,
whichever comes first.
•
The rate at which the filter element is contaminated will be greatly affected by the qualify
of the incoming air. If the air is wet and contaminated with lubricant, the filter element will
need more frequent replacement.
8.3.2 Inspections
On a daily basis, the operators should inspect for:
1) Leaks
at:
•
Pneumatic system (air supply).
•
Filter bottle drain.
2) Loose
fasteners.
3) Inspect the belt condition, tracking and tension
4) Irregular noise or signs of machine wear.
Check the ‘S’ box for Satisfactory Performance and ‘US’ box for Unsatisfactory Performance.
Table 23: Machine Inspection
Maintenance and Cleaning
Inspection
S
US
Inspect the pneumatic system for leaks.
Inspect the drain bottle for overflow.
Inspect for loose fasteners.
Inspect the belt condition, tracking and tension.
Inspect for irregular noise and signs of wear.
Summary of Contents for WF-10T
Page 2: ...WF 10T Case Former ...
Page 118: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 106 ...
Page 119: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 107 ...
Page 120: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 108 ...
Page 121: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 109 ...
Page 122: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 110 ...
Page 123: ...WF30T Case Former Appendix A MSDS Geralyn FMG 387 111 ...
Page 125: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 113 ...
Page 126: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 114 ...
Page 127: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 115 ...
Page 128: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 116 ...
Page 129: ...WF 10T Case Former Appendix B Keystone Nevastane HT 2 117 ...