Water Specialist 1.5" EI & 2LEI
Control Valve
Programming and Drawings Manual
Page 1: ...Water Specialist 1 5 EI 2LEI Control Valve Programming and Drawings Manual...
Page 2: ...t display Changes variable being displayed Key sequence to lock and unlock program settings Holding for 3 seconds intitiates a control reset The software version is displayed and the piston returns to...
Page 3: ...be shown but 0 will be displayed This screen will not be shown if 7 day or 28 day is selected in Configuration Settings Step 3CS PRESS THE DOWN ARROW FOR 3 SECONDS TO RESET TO 0 User 5 Shows current t...
Page 4: ...ess the NEXT and buttons simultaneously for five seconds and release Step 2I Adjust days from 1 28 Press NEXT to go to Step 3I Press REGEN to exit Installer Display Step 3I Use or buttons to set time...
Page 5: ...ttons to set the regen hour Press NEXT to go to Step 5I Press REGEN to go to previous display 7 Day or 7 Volume M3 selected in Configuration Settings Step 3CS Step 1I To enter Installer Display press...
Page 6: ...ength of the regenerant draw from 1 99 minutes or OFF using the or buttons Press NEXT to go to Step 4 CT Press REGEN to return to previous step Step 4CT Adjust the length of the second backwash from 1...
Page 7: ...tely on 0 can only be selected if Volume M3 was selected in step 3CS and a meter must be installed Delay is the only option for the other Step 3CS selections Press NEXT to go to Step 5CS Press REGEN t...
Page 8: ...days since a regeneration last occurred Press NEXT to go to Step 3D Press REGEN to exit Diagnostics Step 3D Display shows the volume of water treated in M3 treated since the last regeneration If 7 or...
Page 9: ...EPLACE 1 5 V3110 WS1 DRIVE REDUCING GEAR 12X36 3 6 V3109 WS1 DRIVE GEAR COVER 1 Not Shown V3186 WS1 AC ADAPTER 110V 12V 1 V3186EU WS1 AC ADAPTER 220 240V 12V EU V3186UK WS1 AC ADAPTER 220 240V 12V UK...
Page 10: ...1 and V3401BSPT 01 NPT threads on drain and injector ports on V3400BSPT 01 V3174 WS1 Regenerant Piston not used for backwash only valves V3010 15Z Injector Plug and V3195 01 WS1 Refill Port Plug ASY m...
Page 11: ...TubePoly 3 8 x 1 4 Blk 500 Ft Roll 0006 Not Shown JG PP481222W Elbow Fix 3 8 x 1 4 NPTF Polypro 2 10 V3453 03 WS2L Body 4 8 NPT w V3468 Plug 1 V3453BSPT 03 WS2L Body 4 8 BSPT w V3465 Plug Not Shown V3...
Page 12: ...g the meter break out the tab in the back plate and thread the meter cord through WHEN INSTALLING THE METER MAKE SURE THE ARROW ON THE METER BODY IS GOING THE SAME DIRECTION AS THE WATER FLOW Order nu...
Page 13: ...r Asy G Green V3010 15H WS1 5 Injector Asy H Orange V3010 15Z WS1 5 Injector Plug 5 V3404 WS1 5 Injector Screen 1 Not Shown V3171 O ring 013 Not Shown V3416 O ring 012 The injector or the injector plu...
Page 14: ...Port Plug Asy 1 2 V3415 WS1 5 BLFC Adapter 1 3 H4615 Clip Retaining 1 4 V3428 WS1 5 Refill Retainer ASY 1 5 V3163 O ring 019 1 6 H4612 Elbow Cap 1 7 JCPG 8PBLK Nut Compression Black 1 8 JCP P 8 Inser...
Page 15: ...fitting is used V3162 042 WS1 DLFC 4 2 gpm 15 9 lpm for V3162 053 WS1 DLFC 5 3 gpm 20 1 lpm for V3162 065 WS1 DLFC 6 5 gpm 24 6 lpm for V3162 075 WS1 DLFC 7 5 gpm 28 4 lpm for V3162 090 WS1 DLFC 9 0...
Page 16: ...for 1 One DLFC must be used if 1 fitting is used V3190 100 WS1 DLFC 10 0 gpm 37 9 lpm for 1 V3190 110 WS1 DLFC 11 0 gpm 41 6 lpm for 1 V3190 130 WS1 DLFC 13 0 gpm 49 2 lpm for 1 V3190 150 WS1 DLFC 15...
Page 17: ...awing No Order No Description Quantity 1 V3053 WS2 2 1 2 GROOVELOCK CLAMP ASY 1 2 V3290 WS2 GROOVE LOCK SEAL 2 5 1 3 V3269 WS2 NUT 5 16 18 SS HEX 1 4 V3293 WS2 WASHER SS 5 16 FLAT 1 5 V3276 WS2 BOLT H...
Page 18: ...Page 18 WS 1 5 EI 2LEI Manual...
Page 19: ...WS 1 5 EI 2LEI Manual Page 19...
Page 20: ...d in Step 3I select Day Override oFF Select ALTA for the control valve that has the two pin connector labeled DRIVE connected to the alternator valve motor Select ALTb for the control valve that will...