1. Product Description

1.1 Introduction

Powered with a BLDC motor, the disc rotator guarantees maintenance-free longevity and 

quiet performance. The intuitive digital display allows for the quick and easy setting of 

parameters without compromising on convenience.

With a variable speed ranging from 10 to 80 RPM, the disc rotator has a variable time 

setting of one to 99 minutes and an infinite mode. Furthermore, the user-programmable 

mode enables the user to set up to nine user-defined programs for unprecedented 

convenience.

A microprocessor-based closed-loop operation allows for exact speed control under 

varied load conditions. In addition, the pulse mode with the Run-Pause-Run function 

allows for thorough mixing of the solution.

The auto power on feature starts the device automatically after a power failure and runs 

for the remaining left time. Furthermore, the tool free removal and/or installation of the 

disc plates allows for proper cleaning and improved contamination protection.

1.2 Intended Use

The disc rotator is used in laboratories for mixing blood samples, viscous samples, 

and for liquid-solid suspensions.

1.3 Features

• 

Brushless DC Motor

• 

Digital Display, Microprocessor Controlled

• 

Suitable for 1.5ml, 2ml, 5ml, 15ml & 50ml Centrifuge Tubes

• 

Nine User-Programmable Modes

• 

Adjustable Speed 10 to 80 RPM

• 

Last Run Memory Feature

• 

Gentle Rotating Motion

• 

Auto Power On Feature

• 

Pulse Mode Function

TABLE OF CONTENT

1.

   Product Description

 

1.1

 Introduction 

1.2

  Intended Use 

1.3

  Features 

1.4

 Accessories

2.

  Technical Specifications

3.

  Safety Precautions

4.

  Maintenance & Cleaning

5.

 Installation

6.

 Operation

7.

 Troubleshooting

8.

  Product Disposal 

PRODUCT CODE

665-106

PLEASE READ THESE INSTRUCTIONS BEFORE USE.

Summary of Contents for 665-106

Page 1: ...1 PRODUCT MANUAL Digital Disc Rotator Set 300 4200RPM Code 665 106...

Page 2: ...oad conditions In addition the pulse mode with the Run Pause Run function allows for thorough mixing of the solution The auto power on feature starts the device automatically after a power failure and...

Page 3: ...fications Motor Type Brushless DC motor Motion Type Rocking Digital Display Yes Programmable Mode Set and save up to nine user defined programs Pulse Mode Alternates between clockwise and anticlockwis...

Page 4: ...disc plate during operation If liquids are spilled on the disc plate the unit must be cleaned properly before being used again Prior to mixing the tubes should be visually inspected for material dama...

Page 5: ...el the product warranty may become void 5 Installation 1 Open the packaging and gently remove the disc rotator from the box 2 Place the unit gently onto a firm and levelled surface 3 Unpack every indi...

Page 6: ...lab com 1 877 822 1455 sales ca westlab com www westlab com Australia New Zealand United States Canada Removing the disc plates The disc plate can be removed by turning the knob in a counter clockwise...

Page 7: ...5 sales ca westlab com www westlab com Australia New Zealand United States Canada Connecting the power adaptor 1 Connect one side of the power adaptor to the rear side of the unit and the other side t...

Page 8: ...e program mode and use the speed time and increment decrement buttons to set the required parameters for the selected program Setting the speed Press the Speed button to select the speed value and the...

Page 9: ...ing that the pulse mode operation is activated Press the Pulse button again to stop ongoing pulse mode operation The user can also press the Start Stop button to stop the operation Example The speed v...

Page 10: ...lect any program from P1 to P9 The programs can also be selected by pressing increment and decrement buttons Once the desired program is selected press the Speed button to select and set the speed val...

Page 11: ...inutes The unit saves the run time every five minutes of operation To select power mode long press the Time button Until this function is reactivated the disc rotator will not resume its operation aft...

Page 12: ...enience 12 PRODUCT MANUAL 1800 358 101 sales au westlab com www westlab com au 64 9 553 3677 sales nz westlab com www westlab co nz 646 568 5391 sales us westlab com www westlab com 1 877 822 1455 sal...

Reviews: