TECHNICAL DATA
Dimensions
Width
Height
Depth
596 mm
818 - 878 mm
580 mm
Electrical connection
Voltage
Overall power
Fuse
Frequency
220-240 V
2200 W
10 A
50 Hz
Water supply pressure
min.
max.
50 kPa (7 psi)
800 kPa (116 psi)
Capacity
Place settings
13
INSTALLATION
If floor is not level, adjust
levelling legs to suit
The hos e s hould not be
extended by more than
2 metres or water pump-
out problems ma y occu r
Remove entire plastic
membrane from sink trap
spigot & fit drain hose to spigot
with clamp
There should be a minimum
2mm gap between the top of
the dishwasher and
underside of bench top
•
kickplate fixing screws
•
Gap on both sides should be
equal, & no greater than
5 mm per side.
600 mm max.
300 mm min.
Secure dishwasher with
brackets and screws provided
600 mm
820-880 mm
Warning!
Make sure that mains plug is
disconnected from the mains socket
during installation.
Install the appliance under a kitchen coun-
ter.
If a repair is necessary, the appliance must
be easily accessible for the engineer.
Put the appliance adjacent to a water tap
and drain.
For the venting of the appliance only water
hoses and mains cable openings are nec-
essary.
The appliance has adjustable feet to allow
the adjustment of its height.
Make sure that the water inlet hose, the
drain hose and the mains cable are not
kinked or squashed, when you insert the
appliance.