INSTALLATION

Standard ducting installation

It is recommended that the unit be positioned at a 
minimum of 600mm for an electric cooktop and 650mm 
for a gas cooktop, and no further from the cooktop than 
800mm. The unit becomes less effective as the distance 
from the cooking surface to the rangehood increase.

650

GAS

ELECTRIC

600

Fixing point dimensions – WRI514BB

Fixing point dimensions – WRI814BB

 WARNING!

Failure to install the screws or fixing  device in 

accordance with these instructions may result in 

electrical hazards.

Parts supplied with hood

1 x Ø 150mm air outlet

2  x self tapping screws 3.5 x 12mm

Parts to be purchased

•  Aluminium tape or cable ties to secure flue pipe
•  Ducting accessories 

Cutting the cabinet

Cut the slot in the cabinet according to the fixing
point dimension.

 

Fixing the air outlet

underside of  

rangehood

top of cooking 

surface

if the cooktop 

manufacturer 

specifies 

a greater 

clearance 

then that 

must be used

Use screws to fix the air outlet to the rangehood.  

1 x Ø 150-120mm reducer

454

492

25

4

27

7

150

28

2

457~475

260

~2

65

Cabinet

12~23

792

744

27

7

25

0

31

2

150

Cabinet

762~766

257

~26

3

12~23

Fixing the rangehood

Fix the rangehood to the cabinet from bottom side 
untill you hear the ‘click’ sound.

ST 3.5x12

Summary of Contents for WRI514BB

Page 1: ...INSTALLATION USER MANUAL WRI514BB WRI814BB INTEGRATED RANGEHOOD ...

Page 2: ...sehold and similar applications such as Staff kitchen areas in shops offices and other working environments Farm houses By clients in hotels motels and other residential type environments Bed and breakfast type environments Catering and similar non retail applications CONTENTS 3 Important safety instructions 4 Installation 6 Operation and maintenance 7 Warranty RECORD MODEL AND SERIAL NUMBER HERE ...

Page 3: ...ve pots or pans CAUTION Accessible parts may become hot when used with cooking appliance Regulations concerning the discharge of air have to be fulfilled Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards Cleaning Wipe the rangehood body and flue with a sponge or soft cloth soaked in warm soapy water and dry with a soft cloth for s...

Page 4: ...hazards Parts supplied with hood 1 x Ø 150mm air outlet 2 x self tapping screws 3 5 x12mm Parts to be purchased Aluminium tape or cable ties to secure flue pipe Ducting accessories Cutting the cabinet Cut the slot in the cabinet according to the fixing point dimension Fixing the air outlet underside of rangehood top of cooking surface if the cooktop manufacturer specifies a greater clearance then ...

Page 5: ...gid flue pipe AR150F AR125F flexible duct AR150FD AR125FD flue joiner AR125FJD with damper wall vent kit AR150WV AR125WV bend AR150FD AR125B AR610CF For best performance Ø 150mm ducting is recommended Ø 125mm ducting can be used but will reduce the airflow of the rangehood Accessories can be bought from your local appliance retailer or in Australia at our online spare parts and accessories store s...

Page 6: ...sure that the filters are completely dry before refitting Replacing the lamp Take care of sharp edges during installation maintenance and cleaning When the filters light cover or fascia panel are removed wear gloves for protection Suitable lamp for replacement 1 2 3 4 5 1 Lamp on off 4 Speed 2 2 Delay end 5 Speed 3 3 Speed 1 Speeds Speed 1 light frying boiling Speed 2 frying wok cooking heavy boil...

Page 7: ...he Appliance caused by i negligence or accident ii misuse or abuse including failure to properly maintain or service iii improper negligent or faulty servicing or repair works done by anyone other than an Electrolux authorised repairer or ASC iv normal wear and tear v power surges electrical storm damage or incorrect power supply vi incomplete or improper installation vii incorrect improper or ina...

Page 8: ...For more information on all Westinghouse appliances or for dimension and installation information call into your retailer phone or email our customer care team or visit our website and WESTINGHOUSE are trademarks of Westinghouse Electric Corporation Used under license All Rights Reserved 2019 Electrolux Home Products Pty Ltd ABN 51 004 762 341 WMAN_WRI514BB_WRI814B_TAS_Dec 19 ...

Reviews: