IMPORTANT SAFETY INSTRUCTIONS(CONTINUED)

Electrical connection

Check that the mains voltage matches with the voltage
on the data plate inside the canopy rangehood. 

Check that the installation complies with standards of local
building, gas and electrical authorities. Before connecting
to the mains supply ensure that the mains voltage
corresponds to the voltage on the rating plate inside the 
cooker hood.

If the supply cord is damaged, it must be replaced by the 
manufacturer or its service agent or similarly qualified
person in order to avoid a hazard.

Safety warnings - for the installer

When installing the cooker hood, make sure you adhere
to the minumum and maximum distances from the cooker
hood base to the hob surface (refer to page 7).

Exhaust flue installation: The following rules must be
strictly followed to obtain optimal air extraction.

Keep exhaust flue short and straight.

Do not reduce the size or restrict exhaust flue.

Keep bends in the exhaust flue to a minimum.

When using flexible flue always install duct with helix
pulled taut to minimise pressure loss.

Failure to observe these basic instructions will
drastically reduce the performance and increase the 
nosie levels of the cooker hood.

Exhaust air must not be discharged into a wall cavity,
unless the cavity is designed for that purpose. The 
exhaust from the cooker hood must not be discharged
into any heating flue, which may carry combustion 
products from other sources.

NOTE: Some installations may require the telescopic
exhaust cover to be cut to length. Cut with sharp tin snips
or a fine-tooth hack saw blade, taking care not to distort
or dent the exhaust cover.

This appliance is not intended for use by persons 
(including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning 
use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not 
play with the appliance.

If the supply cord is damaged, it must be replaced by the 
manufacturer, its service agent or similarly qualified 
persons in order to avoid a hazard.

There is a fire risk if cleaning is not carried out in accordance
with the instructions.

The air must not be discharged into a flue that is used for 
exhausting fumes from appliances burning gas or other fuels
(not applicable to appliances that only discharge the air 
back into the room)

Regulations concerning the discharge of air have to be fulfilled.

CAUTION

: Accessible parts may become hot when used with

cooking appliances.

Summary of Contents for WRC604WC

Page 1: ...WRC604WC CANOPY RANGEHOOD...

Page 2: ...e fee could be applicable Record model and serial number here Model number Serial number PNC CONTENTS CONTENTS Important safety instructions Description of your rangehood Components list Please read t...

Page 3: ...IMPORTANT SAFETY INSTRUCTIONS...

Page 4: ...the cooker hood Exhaust air must not be discharged into a wall cavity unless the cavity is designed for that purpose The exhaust from the cooker hood must not be discharged into any heating flue which...

Page 5: ...attach flue cover mounting brackets Worm drive clamps duct tape or cable ties Technical specification Power supply AC 220 240V 50Hz Connects to 10 A power point Lights 2 2 watt 240V E14 LED MODEL WRC6...

Page 6: ...RANGEHOOD DIMENSIONS DIMENSIONS Fig 4...

Page 7: ...192 130 350 55 273 Min 600mm Max 800mm 140 Installation Using a spirit level mark a vertical centre line on the wall where the hood is to be positioned and a horizontal line at the hood base position...

Page 8: ...tion ducting mode follow step 6a or 6b below Fix the T piece to the top mounting bracket by using the 4 screws supplied as dimension indicated Fig 5 Adhere two sponge to the outlet of T piece Using th...

Page 9: ...flue tape to air outlet with suitable duct tape 6b Fig 11 NOTE f pipe through the roof cladding with appropriate flashing to an external roof cowl venting the exhaust externally or ducted mode we rec...

Page 10: ...es and abrasions so please follow the cleaning instructions to ensure the best possible result is achieved without damage Clean the outside of the hood using a damp cloth and a solution of water and m...

Page 11: ...er can occur this does not have any impact on it s performance Note The metal grease filters must be removed and washed either by hand or in the dishwasher every four weeks minimum Clean the inner hou...

Page 12: ...tly vented to allow the entry of fresh air The grease filters are clean If set up for recirculation check that charcoal filter is still effective If set up for extraction check the ducting and outlets...

Page 13: ...13...

Page 14: ...14...

Page 15: ......

Page 16: ...AN FAC WRC604WC MAY 20 AUSTRALIA phone 13 13 49 email customercare electrolux com au web westinghouse com au NEW ZEALAND phone 0800 10 66 20 email customercare electrolux co nz web westinghouse co nz...

Reviews: