background image

INSTALLATION

PRE-INSTALLATION

Before installing the cooker hood, peel off any protective coating.

INSTALLATION

1. Using a spirit level mark a vertical centre line on the wall where the hood is to be positioned, and a horizontal line

    at the hood base position. (See Figure 4, 5, or 6 for relevant model)

NOTE. The height of the underside of the hood body must be a minimum of 600mm* to a maximum height of 800mm.

* If the instructions of the hob specify a greater distance than the minimum above, then that shall be the minimum

   height for installation.

2. Mark the location for the flue cover wall mounting brackets and rangehood mounting points and anti-tilt fixing

    points above the hood base using the hood base as a reference point

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

130 mm 

250 mm 

230 mm 

28

m

m

 

58

m

m

 

40

 m

m

 

250 mm 

250 mm 

M

ax. 

11

00

 m

m

 

An

ti tilt fixin

g po

i

n

t

 

Range hood 
moun

ti

ng po

i

n

t

F

lu

e cover w

all

 

moun

ti

ng bracke

ts

 

ceili

ng 

M

in

. 600 mm* 

Max. 800 mm 

Top of hob

Fig. 7

 7

LOCATION

The hood is to be mounted on the wall. When installed, the hood must be not less than 60cm above electric burners or

65cm above gas or mixed-fuel burners.

Distance from hood base to top of hob

hob type

minimum*

maximum

gas

650mm

800mm

electric

600mm

800mm

If the instructions of the hob specify a greater distance than the minimum above, then that shall be the minimum height

   for installation.

Summary of Contents for WRC313S

Page 1: ...INSTALLATION AND USER MANUAL WRC313S Rangehood WRCG933S Canopy Rangehood WRFG943S Canopy Rangehood ...

Page 2: ...fast type environments Record model and serial number here Model Serial No TIPS INFORMATION IMPORTANT CHECK FOR ANY DAMAGES OR MARKS If you find the rangehood is damaged or marked you must report it within 7 days if you wish to claim for damage marks under the manufacturers warranty This does not affect your statutory rights UNPACKING Check that the cooker hood has no damage Transportation damage ...

Page 3: ...d into a wall cavity unless the cavity is designed for the purpose There must be adequate ventilation of the room when the canopy rangehood is used at the same time as appliances burning gas or other fuels Always cover lit gas burners with pots or pans when canopy rangehood is in use Always switch off gas burners before you remove pots or pans Do not leave lit gas burners exposed due to the risk o...

Page 4: ...Duct tape or cable ties Ducting accessories Technical specification Power supply 240 Volts 50 Hz Connects to 10A power point Lights 2 x 4 watt 240 volts LED MODEL Height Width Depth Max absorbed power Lighting Outlet diameter Electrical connection WRC313S WRCG933S WRFG943S 600 mm 1 100 mm 320 mm 290 mm 338 W 2 x 4W LED GU10 fitting 150 mm 220 240V 50 Hz 600 mm 1 100 mm 900 mm 480 mm 338 W 2 x 4W L...

Page 5: ...RANGEHOOD DIMENSIONS WRC313S 320 290 600 Min 600 Max1100 216 290 296 320 Fig 4 5 ...

Page 6: ...RANGEHOOD DIMENSIONS WRCG933S WRFG943S Fig 5 Fig 6 320 290 480 900 90 600 Min 600 Max1100 216 290 296 320 320 290 480 900 600 Min 600 Max1100 216 290 296 320 35 6 ...

Page 7: ... for the flue cover wall mounting brackets and rangehood mounting points and anti tilt fixing points above the hood base using the hood base as a reference point 130 mm 250 mm 230 mm 286 mm 587 mm 40 mm 250 mm 250 mm Max 1100 mm Anti tilt fixing point Range hood mounting points Flue cover wall mounting brackets ceiling Min 600 mm Max 800 mm Top of hob Fig 7 7 LOCATION The hood is to be mounted on t...

Page 8: ... of 30kg to the wall as marked Fig 7 2mm A B 6 Hang the body hood on the mounting screws then secure at the anti tilt locations as indicated in Fig 7 8 5 Fix exhaust transition duct using screws supplied Fig 10 A B 4 Remove the protective plastic film from the hood body and telescopic flue cover carefully then assemble together Fig 8 Fig 11 Fig 10 Fig 9 8 B ...

Page 9: ...lation kit AR910RK to prevent odours being emitted back into the room 7b Ducted mode Fig 13 Fit a 150mm diameter non combustible flue pipe Continue the centre line to the ceiling Fit flue pipe to the fan transition duct Use cable ties or suitable duct tape to secure flue pipe to the transition duct NOTE For ducted mode extend the flue pipe through the roof to external china hat to vent exhaust ext...

Page 10: ...rculation kit AR910RK To complete the rangehood installation insert the filters to the underside of the hood body Place back edge of filter into position and push up front edge so that the filter clips into place Your Westinghouse rangehood is now ready to use Care must be taken to ensure the screws are not cross threaded when attaching the upper flue cover CAUTION 10 Only for model WRCG933S and W...

Page 11: ... G CARE MAINTENENCE External surfaces are susceptible to scratches and abrasions so please follow the cleaning instructions to ensure the best possible result is achieved without damage CAUTION Cleaning the hood Clean the outside of the hood using a damp cloth and a solution of water and mild washing up liquid Clean stainless steel surfaces using non abrasive cleaning products that are specificall...

Page 12: ...e replaced by lamps with an aluminium reflector never dichroic lamps to avoid unnecessary overheating in the lamp holders NOTE The metal grease filters must be removed and washed either by hand or in the dishwasher every four weeks Clean the inner housing using warm water and grease loosening cleaner never use caustic detergents abrasive powders or brushes Charcoal filter The charcoal filter shoul...

Page 13: ...eset If the hood has been installed below the heights indicated in the installation instructions the motor will cut out frequently which will damage the hood The cooker hood is not working The cooker hood has switched off during operation If you have completed all of the above checks and are still experiencing difficulty please contact your local Electrolux Service Centre NOTE This product is fitt...

Page 14: ... Part Numbers Description AR150RC AR150F AR150WV AR610CF AR610FS AR910RK 150mm G Bond Roof Cowl 150mm G Bond Flue 1200mm 150mm Wall Vent duct Replacement carbon filter Stainless steel exhaust cover extension 1200mm Recirculating Kit 150 120mm reducer T piece carbon filters 14 ...

Page 15: ...trolux is not liable in the following situations which are not exhaustive a the Appliance is damaged by i accident ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation vi incorrect improper or inappropriate operation vii insect or vermin infestation viii ...

Page 16: ... installation information call into your retailer phone or email our customer care team or visit our website TOP SERVICE Top Service encompasses the after sales service provided by The Electrolux Group to consumers including delivery home service and spare parts Westinghouse We are part of the Electrolux family Share more of our thinking at www electrolux com Part number 0342001598 Issue A 2012 El...

Reviews: