Problem

Possible Cause

Solution

Air conditioner not oper-

ating

Power failure

Wait after power recovery.

Loose plug

Reinsert the plug.

Air switch is tripped or fuse is burnt

Have unit serviced to replace air switch or fuse.

Is there malfunction for the circuit?

Have unit serviced to replace circuit.

Unit is restarted too quickly after stopping

Wait for 3 minutes, and then turn on the unit  again.

Evaporator needs to be defrosted (observe it by 

pulling out the filter)

Normal phenomenon. Air conditioner is defrosting. After de-

frosting is finished, it will resume operation.

Poor  cooling (heating)

Is an extension cord being used? (Can cause low 

input power.)

Move unit closer to power source, or use a shorter, heavier 

gauge extension cord.

Air filter is too dirty

Clean the air filter.

Set temperature is too low/high

Adjust the temperature.

A door or window is open.

Close door and window.

Air conditioner can’t receive 

signal from  remote control 

or  remote control is not 

sensible

The unit is interfered with seriously (such as static 

pressure, unstable voltage)

Unplug the unit wait three (3) minutes, plug in again, and 

then turn on the unit.

Remote control is not within receiving range.

The receiving range of  remote control is 8 meters. Do not 

exceed this range.

The receiver on the air conditioner is blocked.

Remove the obstacles.

Sensitivity of the  remote control is low

Check the batteries of  remote control. If the power is low, 

replace the batteries.

There is a fluorescent lamp in the room.

Move the  remote control close to air conditioner.

Turn off the fluorescent lamp and try it again.

The unit is making a crack-

ling sound.

Unit was recently turned off/on.

Heat expansion or shrinkage due to change of temperature.

Abnormal sound during 

operation

Interference from radio, thunderstorm, or other elec-

trical activity.

Disconnect power, wait 3 minutes, then reconnect and turn 

on the unit again.

Unpleasant odor in the 

room

There is some odor source nearby (cigarettes, dirty 

rug, etc.)

Eliminate the source of the odor.

Clean the filter.

No air blowing from air con-

ditioner

Air outlet or air inlet is blocked

Eliminate the obstacles.

Set temperature can’t be 

adjusted.

The required temperature exceeds the temperature 

setting range.

Temperature setting range: 61°F(16°C) 86°F(30°C).

You can heard water-flow

-

ing sound

The unit was just turned on or turned off.

Sound of refrigerant inside the air conditioner, which is nor-

mal.

Summary of Contents for WPAC10000

Page 1: ...USER MANUAL Portable Room Air Conditioner Models WPAC8000 WPAC10000 DO NOT RETURN THIS PRODUCT TO THE STORE If you have questions or need assistance please call customer service at 855 944 3571...

Page 2: ...wed in any form without written permission from Westinghouse Outdoor Power Equipment Read this manual before using or performing maintenance on this product Failure to follow the instructions and safe...

Page 3: ...MANUAL FOR FUTURE REFERENCE PRODUCT REGISTRATION For trouble free warranty coverage it is important to register your Westinghouse generator You can register by Completing and mailing the product regis...

Page 4: ...out the power plug Ensure that the power cord is undamaged Do not pull or drag the power cord to pull out the power plug or move the air conditioner Do not insert or pull out the power plug with wet h...

Page 5: ...lso lower R32 has very good thermodynamic features and high energy efficiency The units therefore need less filling Appliance filled with flammable gas R32 Appliance shall be installed operated and st...

Page 6: ...tdoor Power Equipment INSTALLATION INSTALLATION UNIT OVERVIEW 2 5 Louver vent Exhaust connector 1 Control panel 1 2 3 4 7 6 3 Caster 4 Filter 5 8 9 Remote control 6 Exhaust duct 7 Window clip 8 Power...

Page 7: ...as far away as possible from fluorescent lighting Do not install in laundry area POWER REQUIREMENTS Follow all electrical safety regulations when installing the unit Use a qualified power supply circ...

Page 8: ...ly Do not operate the air conditioner in a humid environment Keep air inlet and air outlet clean and free of obstacles Reserved space around the air conditioner 30cm 12 inches INSTALL EXHAUST DUCT Whe...

Page 9: ...Tape measure or ruler Knife or scissors Saw In the event that the window panel needs to be cut down in size because the window is too narrow for direct installation INSTALL WINDOW PANEL 1 Open the wi...

Page 10: ...gth of window panel please use the adjustment panel to make sure you can span the entire length of your window Otherwise you can add an extension panel to prolong the length of the windows panel assem...

Page 11: ...place unit on a level surface and make sure the hose is clear of any obstructions and directed downward Placing unit on an uneven surface or improper hose installation may result in water filling up t...

Page 12: ...dry batteries 3 Reinstall the cover of battery box Reinstall Signal sender Battery Remove Cover of battery box TEST OPERATION 1 Plug in the power supply 2 Press ON OFF button on remote control to star...

Page 13: ...will increase or decrease 0 5 hour by pressing or button within 10 hours while timer setting will increase or decrease 1 hour by pressing or button beyond 10 hours After timer setting is finished the...

Page 14: ...to Low Med or High 2 Buttons In cooling mode press or button to increase or decrease set temperature by 1 F C 3 Cool Mode Press to change operation to Cool mode 4 ON OFF Press this button to turn on o...

Page 15: ...e front of the unit Adjust this louver to direct air flow 2 Press the ON OFF button from the remote or from the control panel to start the unit 3 Select operating mode Cool Fan or Dry 4 In cooling mod...

Page 16: ...hen put it in a shady place to dry it 3 After the filter is cleaned and dried reinstall it CLEAN EXHAUST DUCT 1 Remove the exhaust duct from air conditioner clean and dry it and then reinstall it EMPT...

Page 17: ...lease maintain it by following steps for good performance 1 Make sure there s no accumulated water in chassis and the exhaust duct is disassembled 2 Pull out the plug and wrap the power cord 3 Clean t...

Page 18: ...g the unit wait three 3 minutes plug in again and then turn on the unit Remote control is not within receiving range The receiving range of remote control is 8 meters Do not exceed this range The rece...

Page 19: ...o high pow er off the unit and then energize it for operation after the ambient temperature drops to 95 F 35 C below Check if the evaporator and condenser are blocked by some objects if yes take away...

Page 20: ...ould a product difficulty occur you must at your expense deliver or ship your Westinghouse Outdoor Power Equipment LLC unit to an Authorized Service Dealer for warranty repairs which must occur within...

Page 21: ...le Air Conditioners and its affiliated companies shall not be liable for any special incidental or consequential damage including lost profits There are no warranties extended other than as provided h...

Page 22: ...seOutdoorPower com and Westinghouse are trademarks of Westinghouse Electric Corportaion Used under license by Westinghouse Outdoor Power Equipment All Rights Reserved WPAC8000 WPAC10000 66139902592 Re...

Reviews: