Specifications
Type
Wall mounted
Inverter heat pump
Model name
WHZ09WMA21S
WHZ12WMA21S
Power supply
208/230 V ~ 60 Hz
Power supply intake
Outdoor unit
Available voltage range
187—253 V
Capacity
Cooling
Rated
kW
2.64
3.52
Btu/h
9,000
12,000
Min.—Max.
kW
1.06—2.93
1.17—3.96
Btu/h
3,600—10,000
4,000—13,500
Heating
Rated
kW
3.08
3.81
Btu/h
10,500
13,000
Min.—Max.
kW
1.06—3.08
1.17—4.10
Btu/h
3,600—10,500
4,000—14,000
Input power
Cooling
Rated
kW
0.560
0.780
Min.—Max.
0.100—1.060
0.130—1.280
Heating
Rated
0.770
0.855
Min.—Max.
0.130—1.220
0.170—1.430
Current
Cooling
Rated
A
2.3
4.6
Heating
3.4
4.8
EER
Cooling
W/W
4.71
4.51
Btu/hW
16.07
15.40
COP
Heating
W/W
4.00
4.45
Btu/hW
13.64
15.20
SEER
Cooling
Btu/hW
28.0
25.0
HSPF
Heating
Btu/hW
12.5
12.0
Power factor
Cooling
%
97
96
Heating
97
97
Moisture removal
pints/h (L/h)
1.9 (0.9)
2.5 (1.2)
Maximum operating current*
1
Cooling
A
6.5
7.0
Heating
6.5
7.0
Fan
Airflow rate
Cooling
HIGHER
CFM (m
3
/h)
394 (670)
618 (1,050)
HIGH
365 (620)
559 (950)
MED
294 (500)
483 (820)
LOW
235 (400)
453 (770)
LOWER
224 (380)
365 (620)
Heating
HIGHER
394 (670)
618 (1,050)
HIGH
365 (620)
559 (950)
MED
294 (500)
483 (820)
LOW
235 (400)
453 (770)
LOWER
224 (380)
365 (620)
Type × Q'ty
Crossflow fan × 1
Motor output
W
25
35
Sound pressure level*
2
Cooling
HIGHER
dB (A)
42
48
HIGH
39
46
MED
34
41
LOW
31
37
LOWER
28
30
Heating
HIGHER
42
48
HIGH
39
46
MED
34
41
LOW
31
37
LOWER
28
30
Heat exchanger type
Dimensions (H × W × D)
in (mm)
11-9/16 × 24-7/16 × 1-1/16 (294 × 620 × 27.2)
14-7/8 × 27-3/4 × 1-1/16 (378 × 705 × 27.2)
Fin pitch
FPI
18
Rows × Stages
2 × 14
2 × 18
Pipe type
Copper
Fin type
Aluminum
Enclosure
Material
Polystyrene
Color
White
Dimensions
(H × W × D)
Net
in (mm)
10-5/8 × 33-7/16 × 8-7/16 (270 × 850 × 215)
12-3/8 × 37-13/16 × 9-5/16 (315 × 960 × 236)
Gross
13-3/16 × 37 × 10-7/16 (335 × 940 × 265)
15-3/8 × 40-15/16 × 12-7/16 (390 × 1,040 × 316)
Weight
Net
lb (kg)
20 (9)
29 (13)
Gross
24 (11)
33 (15)
Connection pipe
Size
Liquid
in (mm)
Ø1/4 (Ø6.35)
Gas
Ø3/8 (Ø9.52)
Method
Flare
Drain hose
Material
PE/PVC
Tip diameter
in (mm)
Ø5/8 (Ø15.4) (I.D.), Ø7/8 (Ø23) (O.D.)
Operation range
Cooling
°F (°C)
61 to 86 (16 to 30)
%RH
80 or less
Heating
°F (°C)
61 to 86 (16 to 30)
Remote controller type
Wireless (Wired [option])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB (26.67 °CDB) /67 °FWB (19.44 °CWB), and outdoor temperature of 95 °FDB (35 °CDB) / 75 °FWB (23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB (21.11 °CDB) /59 °FWB (15.56 °CWB), and outdoor temperature of 47 °FDB (8.33 °CDB) /43 °FWB (6.11 °CWB).
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum current is maximum value when operated within the operation range.
• *2: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
-
3
-