Westinghouse WGRTLP199 User'S Information Manual Download Page 9

 

 

 

WHL-005 REV. 7.17.14 

To clean the air intake filter: 
1. Press the Power button on the control panel to turn off the water heater. 
2. Disconnect the power supply from the water heater. 
3. If water heater has been operating, wait for it to cool before continuing. 
4. Remove the front cover of the water heater cabinet. 
5. Pull the filter out of the air intake adapter. 
6. Remove the filter from the plastic assembly and clean it with a toothbrush and clean running water. See Figure 1. 
 

 

Figure 1 

– Cleaning the Air Intake Filter 

7. Dry the filter completely. Then reinsert the filter into the plastic assembly. 
8. Replace the front cover of the water heater cabinet. Reconnect power supply to the water heater. 
9. Press the Power button on the control panel to turn on the water heater. 

C. 6 MONTH MAINTENANCE 

Check Primary and Gas Piping 

 

Remove the water heater cover and perform a gas leak inspection following Operating Instructions, page 2, this manual. If gas 
odor or leak is detected, follow procedures on page 2. Call a qualified service technician. 

 

Visually inspect for leaks around the internal water heater water connections and around the heat exchanger. Visually inspect 
the external system piping, circulators, and system components and fittings. Immediately call a qualified service technician to 
repair any leaks 

 

 

Have leaks fixed at once by a qualified service technician. Failure to comply could result in substantial property damage, severe 
personal injury, or death. 
 

Operate Pressure Relief Valve 

 

Before proceeding, verify that the relief valve outlet has been piped to a safe place of discharge, avoiding any possibility of 
scalding from hot water. 

 

Shut power off to the water heater. To avoid scalding, wait for water heater to cool before operating the relief valve. 

 

 

To avoid water damage or scalding due to relief valve operation, a discharge line must be connected to the valve outlet and directed to 
a safe place of disposal. This discharge line must be installed by a qualified service technician or heating/plumbing installer in 
accordance with the water heater installation manual. The discharge line must be terminated so as to eliminate possibility of severe 
burns or property damage should the valve discharge. 
 

 

Lift the relief valve lever. If water flows freely, release the lever and allow the valve to seat. Watch the end of the relief valve 
discharge pipe to ensure that the valve does not weep after the line has had time to drain. If the valve weeps, lift the lever 
again to attempt to clean the valve seat. If the valve does not properly seat and continues to weep, contact a qualified service 
technician to inspect the valve and system. 

Summary of Contents for WGRTLP199

Page 1: ...t Section 1417 IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL INJURY OR LOSS OF LIFE DO NOT STORE GASOLINE OR OTHER FLAMMABLE...

Page 2: ...l result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation...

Page 3: ...NG OPERATION 5 C TROUBLESHOOTING AND GENERAL CAUTIONARY STATEMENTS 6 PART 2 MAINTENANCE 7 A SERVICE TECHNICIAN 7 B OWNER MAINTENANCE 7 PART 3 MAINTENANCE PROCEDURES 7 A DAILY MAINTENANCE 7 B MONTHLY M...

Page 4: ...nician to inspect the water heater and replace any part of the control system or gas control which has been under water DO NOT power up the water heater unless the gas and water supply valves are full...

Page 5: ...der for assistance PRODUCTS TO AVOID AREAS LIKELY TO HAVE CONTAMINANTS Spray cans containing fluorocarbons Dry cleaning laundry areas and establishments Permanent wave solutions Swimming pools Chlorin...

Page 6: ...in property damage serious personal injury or death DO NOT wipe the water heater or control panel with a wet cloth Doing so may result in an electric shock substantial property damage premature water...

Page 7: ...Remove burner assembly and clean burner head using compressed air only Once the maintenance items are completed the service technician should review service with the owner B OWNER MAINTENANCE Periodi...

Page 8: ...aust vent and intake pipe terminations are clean and free of obstructions Remove any debris from the exhaust vent or intake pipe openings If removing the debris does not allow the water heater to oper...

Page 9: ...s and fittings Immediately call a qualified service technician to repair any leaks Have leaks fixed at once by a qualified service technician Failure to comply could result in substantial property dam...

Page 10: ...t clogged with debris Make sure the water heater is connected to the correct gas supply Check that supply and manifold gas pressures are in accordance with specifications Ensure the water flow sensor...

Page 11: ...11 WHL 005 REV 7 17 14 MAINTENANCE NOTES...

Page 12: ...12 WHL 005 REV 7 17 14...

Reviews: