34
WHL-004 REV. 12.17.14
Figure 27
– Status Mode Screens
Parameter
Detail
Description
A: Li or A: GA
Flow 1
Current Flow Value (Li: Liters/min, GA: Gallons/min)
b: Fr
Fan rpm
Current Fan RPM Value
C: Lc
Lock Mode
Lock Mode is In Use (ON) or Unused (OFF)
Allows user to lock out any temperature change.
d: oP
OP Temperature
Current Operating Temperature
E: dH
DHW Temperature
Current DHW Temperature
F: Eh
Exhaust Temperature
Current Exhaust Temperature
h: In
Inlet Temperature
Current Inlet Temperature
L:rt
Running Time
Display Running Time
L:rt
1: PH
Power Supply Time
Power Supply Time: 100 hour increments
2: rh
Burner Operating Time
Burner Operating Time: 1 hour increments
3: rH
Burner Operating Time
Burner Operating Time: 1,000 hour increments
4: It
Ignition Attempts Number
Ignition Attempts Number: 10 times unit displayed
5: IH
Ignition Attempts Number
Ignition Attempts Number: 10,000 times unit displayed
J: AG
N/A
N/A
Table 20
– Status Mode Display Screen Descriptions – NOTE:
Shaded Parameters Not Used on This Software Version
Turn the dial
counterclockwise and clockwise to scroll through the displayed parameters. To view parameter details, press the
button at the appropriate screen. Press the
or
buttons to leave the parameter.
Press the
button again to return to Operation Mode.
To turn on Lock Mode, press the
button at the C:Lc parameter. Turn the dial
counterclockwise and clockwise to scroll On or
Off. Press the
button to save the selection and return to the parameters.
Press the
button again to return to Operation Mode.
NOTE:
The Control System will not allow the changes if Lock Mode is activated. Lock Mode will have to be turned off before making
further changes.
H. INSTALLER MODE
Installer Mode will activate when button B
is pressed and held for five seconds while the water heater is powered Off.