24 | Westinghouse Portable Power
ENGINE OIL MAINTENANCE
Engine Oil Specification
1.
Only use the engine oil specified in Figure 17.
2.
Only use 4-stroke/cycle engine oil.
NEVER USE
2-STROKE/CYCLE OIL
. Synthetic oil is an
acceptable substitute for conventional oil.
Figure 17 - Recommended Oil
CHECKING ENGINE OIL
NOTICE
Always maintain proper engine oil level. Failure to
maintain proper engine oil level could result in severe
damage to the engine and/or shorten the life of the
engine. Always use the specified engine oil. Failure
to use the specified engine oil can cause accelerated
wear and/or shorten the life of the engine.
Engine oil level should be checked before every use.
1.
Always operate or maintain the generator
on a flat surface.
2. Stop engine if running.
3.
Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).
4. With a damp rag, clean around the
oil fill plug/dipstick.
5.
Remove oil fill plug/dipstick (see Figure 18 below).
Figure 18 - Oil Fill Plug/Dipstick
6. Check oil level: When checking the engine oil,
remove the oil fill plug/dipstick and wipe it clean.
Thread the oil fill plug/dipstick all the way back in and
then remove and check the oil level on the oil fill plug/
dipstick.
• Acceptable Oil Level
– Oil is visible on the
crosshatches between the H and L lines on the oil
fill plug/dipstick (see Figure 19).
• Low Oil
– Oil is below the L line on the oil fill plug/
dipstick.
If oil level is below
this line it is too
low to operate.
Figure 19 - Checking Oil Level
ADDING ENGINE OIL
1.
Always operate or maintain the generator
on a flat surface.
2. Stop engine if running.
3.
Let engine sit and cool for several minutes (allow
crankcase pressure to equalize).
4.
Thoroughly clean around the oil fill plug/dipstick.
5.
Remove oil fill plug/dipstick and wipe clean.
6. Select the proper engine oil as specified
in Figure 17.
7.
Using the supplied funnel, slowly add engine oil to
the engine. Stop frequently to check the level to
avoid overfilling.
8. Continue to add oil until the oil is at the correct level.
See Figure 19.
9.
Replace the oil fill plug/dipstick.
MAINTENANCE
Summary of Contents for WGen7500
Page 1: ...USER MANUAL WGen7500 Portable Generator 7500 Running Watts 9500 Peak Watts REMOTE START...
Page 8: ...8 Westinghouse Portable Power SAFETY SAFETY LABELS AND DECALS 8 9 7 10 8 9 6 6 7 5 10...
Page 31: ...Westinghouse Portable Power 31 WGen7500 SCHEMATIC...
Page 32: ...32 Westinghouse Portable Power WGen7500 EXPLODED VIEW...
Page 37: ...Westinghouse Portable Power 37 Version 07 31 18KD...