TROUBLESHOOTING
PROBLEM
POTENTIAL CAUSE
SOLUTION
Engine is running, but no
electrical output
1. Circuit breakers are tripped.
1. Reset the circuit breakers and check
for overload condition.
2. The power cord’s plug connector is not
fully engaged in the generator’s outlet.
2. Verify plug connector is firmly engaged
in the generator’s outlet. If using the
240V outlet, make sure plug connector
is rotated 1/4 turn in the clockwise
direction.
3. Faulty or defective power cord
3. Replace power cord.
4. Faulty or defective electrical appliance
4. Try connecting a known good
appliance to verify the generator is
producing electrical power.
5. If trying 1-5 above does not solve the
problem, the cause might be the generator
has a fault.
5. Take the generator to your nearest
authorized service dealer.
MAINTENANCE
STORING GENERATOR
WARNING
Never store a generator with fuel in the tank
indoors or in a poorly ventilated area where the
fumes can come in contact with an ignition source
such as a: 1) pilot light of a stove, water heater,
clothes dryer or any other gas appliance; or 2)
spark from an electric appliance.
NOTICE
Gasoline stored for as little as 60 days can go bad, causing gum,
varnish and corrosive buildup in fuel lines, fuel passages and the
engine. This corrosive buildup restricts the flow of fuel, preventing
an engine from starting after a prolonged storage period.
Proper care should be taken to prepare the generator for
any storage.
1. Make sure the Engine Switch is switched to .
2.
Clean the generator as outlined in
Cleaning the
Generator
.
3. Drain all gasoline from the fuel tank as best as
possible.
4. With the fuel shut off valve open, start the engine
and allow the generator to run until all the remaining
gasoline in the fuel lines and carburetor is consumed
and the engine shuts off.
5. Close the fuel shut off valve.
6. Drain the remaining gas in the carburetor float bowl
outlined in
Draining Carburetor Float Bowl
.
7.
Change the oil (see
Changing Engine Oil
).
8. Remove the spark plug (see
Spark Plug Maintenance
)
and place about 1 tablespoon of oil in the spark plug
opening. While placing a clean rag over the spark
plug opening, slowly pull there coil handle to allow the
engine to turn over several times. This will distribute
the oil and protect the cylinder wall from corroding
during storage.
9. Replace the spark plug (see
Spark Plug Maintenance
).
10. Move the generator to a clean, dry place for storage.