Westinghouse Outdoor Power Equipment | 19
STOPPING THE GENERATOR
Normal Operation
During normal operation, use the following steps to
stop your generator:
1. Remove any connected loads from the control
panel receptacles.
2. Allow the generator to run at “no load” to reduce
and stabilize engine and alternator temperatures.
3.
Position the engine control switch to
STOP
(see
figure 10).
NOTE If you plan to store the generator after
use, turn the fuel shutoff valve to the OFF
position and allow the fuel to be consumed from
the carburetor.
4. To stop generator remotely hold the
OFF
button on
the wireless control (see figure 11). The generator
may run for an additional 5 seconds as it goes
through a cool down cycle before shutting off.
5. Turn the fuel shutoff valve to the
OFF
position.
During an Emergency
If there is an emergency and the generator must be
stopped quickly, position the engine control switch to
the
STOP
position immediately.
WARNING
Internal pressure can build in the
engine crankcase while the engine
is running. Removing the oil fill plug/
dipstick while the engine is hot can
cause extremely hot oil to spray out
of the crankcase and can severely
burn skin. Allow engine oil to cool for
several minutes before removing the
oil fill plug/dipstick.
Always perform maintenance in a well-
ventilated area. Gasoline fuel and fuel
vapors are extremely flammable and
can ignite under certain conditions.
WARNING
Avoid accidentally starting the
generator during maintenance by
removing the spark plug boot from
the spark plug. For electric start
generators, also disconnect the
battery cables from the battery
(disconnect the black negative (-)
cable first) and place the cables away
from the battery posts to avoid arcing.
Allow hot components to cool to
the touch prior to performing any
maintenance procedure.
OPERATION
MAINTENANCE
Figure 10 - Engine Control Switch to - STOP
Figure 11 - Remote Stop - Hold Stop Button
BEFORE PERFORMING MAINTENANCE ON THE GENERATOR, REVIEW THE SAFETY SECTION
STARTING ON PAGE 5, AS WELL AS THE FOLLOWING SAFETY MESSAGES.
ON
OFF
Summary of Contents for WGen12000
Page 1: ...USER MANUAL WGen12000 Portable Generator 12 000 Running Watts 15 000 Peak Watts ...
Page 30: ...30 Westinghouse Outdoor Power Equipment WGen12000 ENGINE VIEW ...
Page 33: ...Westinghouse Outdoor Power Equipment 33 WGen12000 SCHEMATIC ...
Page 34: ...34 Westinghouse Outdoor Power Equipment Version 10 22 18KD ...