NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires.  These
fixtures meet all UL specifications.

1.  Turn off power at circuit box to avoid possible electric shock.
2.  Secure mounting bar (A) to outlet box (B) with outlet box screws (C) (not included) (see fig. 1).
3.  Thread hex nut (D) onto mounting nipple (E) approximately 1/4 inch and insert lock washer

(F), then thread mounting nipple (E) onto mounting bar (A) and secure with hex nut (D).

4.  Slide fixture column (G) down fixture wires (H) (do not twist or kink wires), then thread 

fixture column (G) onto coupling (I).

5.  Open one link on bottom end of chain (J). Attach to fixture loop (K). Securely close link on 

chain (J).

6.  Thread screw collar ring (L) onto screw collar (M), then place canopy (N) over top of screw

collar (M).

7.  Lace wires up through every other link on chain (J) then through screw collar (M) and 

mounting nipple (E).

8.  Open one link on top end of chain (J). Attach to loop on screw collar (M). Securely close 

link on chain (J).

9.  Identify color coding of fixture wires (see fig. 2).

10.  To connect wires, take black fixture wire (group A from fig. 2) and place evenly against

black outlet box wire. Do not twist wires.

11.  Fit wire connector (O from fig. 1) over wires and twist until there is a firm connection. If

wire connector (O) easily comes off, reattach and check again for a firm connection.

12.  Repeat steps 10 and 11 with the white (group B from fig. 2) fixture wires and outlet box

wires.

13.  Partially thread green grounding screw (P) into side hole (Q) on mounting bar (A) (see fig. 1).
14.  Wrap ground wire from fixture around green grounding screw (P) leaving enough excess 

wire to then connect ground wire and outlet box wire with wire connector (O) (see step 11).

15.  Tighten green grounding screw (P). Do not over tighten.
16.  Remove screw collar ring (L) from screw collar (M) and secure screw collar (M) to mounting

nipple (E).

17.  Tuck wires inside outlet box (B).
18.  Raise canopy (N) to ceiling and secure screw collar ring (L) to screw collar (M).

MOUNTING AND WIRING INSTRUCTIONS

FIXTURE ASSEMBLY INSTRUCTIONS

Warning: This fixture is for indoor use only.

1.  Place socket covers (R) over sockets (S) then place shades (T) over sockets (S).
2.  Install lamps. Do not exceed recommended wattage. 
3.  Secure finial (U) to nipple (V) on fixture base (W).
4.  Turn power back on at circuit box. 

Summary of Contents for W-107

Page 1: ...ixture Installation Instructions W 107 090511 Please write model number here for future reference Veuillez noter le num ro de mod le aux fins de r f rence ult rieure Por favor incluya el n mero del mo...

Page 2: ...purchase price WARNING ELECTRICAL SHOCK CAN RESULT IN SERIOUS INJURY Read and follow instructions exactly as shown If instructions are unclear do not proceed Contact a qualified electrician Read all...

Page 3: ...ixture OUTLET BOX B GREEN GROUNDING SCREW P WIRE CONNECTORS O GROUND WIRE OUTLET BOX SCREWS C MOUNTING BAR A SIDE HOLE Q CANOPY N COUPLING I NIPPLE V LOCK WASHER F HEX NUT D CHAIN J FIXTURE LOOP K FIN...

Page 4: ...t wires take black fixture wire group A from fig 2 and place evenly against black outlet box wire Do not twist wires 11 Fit wire connector O from fig 1 over wires and twist until there is a firm conne...

Page 5: ...rsera le montant du prix d achat 5 MISE EN GARDE L LECTROCUTION POURRAIT CAUSER DE GRAVES BLESSURES PERSONNELLES Lisez ces instructions et suivez les exactement comme illustr En cas de doute ne commen...

Page 6: ...FIL DE MISE A LA TERRE VIS DE LA BOITE DE SORTIE DE COURANT C BARRE DE FIXATION A TROU LATERAL Q CHAPEAU N RACCORD I ECROU DECORATIF U MANCHON FILETE V RONDELLE DE BLOCAGE F L ECROU HEXAGONAL D CHAINE...

Page 7: ...prenez le fil noir de l appareil d clairage groupe A fig 2 et placez le de fa on gale sur le fil noir provenant de la bo te de sortie de courant Ne tournez pas les fils ensemble 11 Ins rez les fils d...

Page 8: ...ADVERTENCIA UNA DESCARGA EL CTRICA PODR A CAUSAR LESIONES Lea y siga las instrucciones exactamente como se indica Si las instrucciones no son claras no proceda con la instalaci n Consulte a un electri...

Page 9: ...ES DE ROSCA O CABLE DE TIERRA TORNILLOS CAJA DE EMBUTIR C BARRA DE MONTAJE A ORIFICIO LATERAL Q DOSEL N ACOPLAMIENTO I NIPLE 1 V FLORON U ARANDELA DE PRESION F TUERCA HEXAGONAL D CADENA J FIJELO AL AS...

Page 10: ...la Fig 2 10 Para conectar los cables tome el cable negro del artefacto grupo A de la Fig 2 y col quelo uniformemente contra el cable negro de la caja de embutir No retuerza los cables 11 Coloque un co...

Page 11: ...IDENCE NOTA Dans le cas des fils parall les SPT I et SPT II le fil neutre est carr et C tel et le fil charg est rond et lisse Voir ci dessus MISE EN GARDE Coupez le courant au site de montage avant de...

Page 12: ...ure an extra protective covering NETTOYAGE ET ENTRETIEN Pour nettoyer essuyez l appareil avec un linge doux Nettoyez le verre l aide d un savon doux Les net toyants chimiques risquent de d colorer le...

Reviews: