Westinghouse LCM - 19v1 User Manual Download Page 6

     

SE-UM-1901-0502 

 

Safety Guidelines 

 

Warning: 

This device must be operated with the original power supply, part number ADP-60CF A. 

CAUTION: 

The power supply outlet should be located near the equipment and should be easily accessible.

 

Use 

a power cable that is properly grounded. Always use the appropriate AC cord that is certified for the individual 
country. Some examples are listed below: 

USA.................UL      

Switzerland ..... SEV 

Canada.............CSA     

Britain ............. BASE/BS 

Germany..........VDE        

Japan ............... Electric Appliance Control Act          

 

IMPORTANT NOTICE CONCERNING POWER CORD SELECTION 

The power cord set for this unit is enclosed and has been selected according to the country of destination and 
must be used to prevent electric shock. Use the following guidelines if it is necessary to replace the original cord, 
or it is not enclosed.   
 
The female receptacle of the cord set must meet IEC-60320 requirements and should look like Figure A1 below: 

                                                   

 

Figure  A1

Figure  A2

 

 

For the United States and Canada 

In the United States and Canada the male plug is a NEMA5-15 style (Figure A2), UL Listed, and CSA Labeled. 
For units that are mounted on a desk or table, type SVT or SJT power cords may be used. If the monitor is 
placed on the floor, only SJT type cord may be used. The power cord must be selected according to the current 
rating for your unit. Please consult the table below for the selection criteria for power cords used in the United 
States and Canada. 

                         

 

Cord Type

 

Size of Conductors in Cord

 

Maximum Current Rating of Unit

SJT

 

18 AWG 
16 AWG 
14 AWG

 

10 Amps 
12 Amps 
12 Amps

 

SVT

 

18 AWG 
17 AWG

 

10 Amps 
12 Amps

 

 

 

FCC Compliance Statement 

 

This equipment has been tested and found to comply with the limits for a Class B digital 
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable 
protection against harmful interference in a residential installation. This equipment generates, 
uses, and can radiate radio frequency energy, and may cause harmful interference to radio 
communications if not installed and used in accordance with the instructions. However, there 
is no guarantee that interference will not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television reception, which can be determined by 
turning the equipment off and on, the user is encouraged to try to correct the interference by 
one or more of the following measures: 

 

 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected. 

• 

Consult the dealer or an experienced technician for help. 

 

FCC Warning: 
To assure continued FCC compliance, the user must use grounded power supply cord and the provided 
shielded cables. Any unauthorized changes or modifications not expressly approved by Westinghouse 
Digital for compliance could void the user's authority to operate this device.

 

Summary of Contents for LCM - 19v1

Page 1: ......

Page 2: ...HE POWER ON 6 OSD MENU FUNCTIONS 7 OSD MENUS 8 BACKLIGHT CONTROL 9 DISPLAY MODES 99 IMAGE PROBLEMS 10 NO SIGNAL INPUT 10 OUT OF RANGE 10 APPENDIX 11 SPECIFICATIONS 11 TROUBLESHOOTING 12 No Power 12 No...

Page 3: ...osing the monitor to rain water moisture or high humidity Do not place it near basins or sinks where it may come in contact with water Never place heavy or sharp objects on the LCD monitor video cable...

Page 4: ...le parts inside The LCD monitor contains high voltage parts You may be seriously injured if you touch them Do not attempt repairs yourself The warranty does not cover repairs or attempted repairs by a...

Page 5: ...lint free cloth and wipe the screen To Clean the Case 1 Use a soft dry cloth 2 If it still is not clean apply a small amount of non ammonia non alcohol based mild non abrasive detergent on a clean sof...

Page 6: ...ion criteria for power cords used in the United States and Canada Cord Type Size of Conductors in Cord Maximum Current Rating of Unit SJT 18 AWG 16 AWG 14 AWG 10 Amps 12 Amps 12 Amps SVT 18 AWG 17 AWG...

Page 7: ...ess the tabs on the bottom of the stand neck and remove the base 2 Connect the VGA and Audio Cables Connect a VGA cable to the connector labeled D SUB and an audio cable to the connector labeled AUDIO...

Page 8: ...on to display the OSD menu Press the or keypad button to select the function to be adjusted Press the Menu keypad button to enter the OSD sub menu to be adjusted Press the or keypad button to change t...

Page 9: ...ff the audio muting Color 9300K Set the color temperature to 9300K white color 7500K Set the color temperature to 7500K white color 6500K Set the color temperature to 6500K white color User Red Adjust...

Page 10: ...ontrolled by using the Turbo button on the control keypad There are 3 modes Economy Text and Picture To toggle between these modes press the Turbo key until the mode you desire is selected These modes...

Page 11: ...put If there is no source connected to the monitor the following error message will be displayed Out of Range If the monitor settings are not compatible with the PC or out of range of the LCD monitor...

Page 12: ...ck male male Speaker Output Built in audio amplifier and speakers 2 5 watts 2 channels Power Voltage 100 240 VAC 50 60 Hz auto switch 1 5A Operating Conditions Temperature 32 F to 95 F 0 C to 35 C Hum...

Page 13: ...k the computer image output resolution and frequency and compare the value with the preset values of the computer s graphics card Fuzzy Image Adjust the Phase setting on the monitor Image Too Bright o...

Page 14: ...e the 100 mm VESA hole pattern to secure a mounting plate to the LCD monitor Use professional installation to reduce the risk of injury and damage Additional Questions See our website at www westingho...

Page 15: ...SE UM 1901 0502...

Reviews: