Installation Guideline 

The installation must be in compliance with the National Electrical Code, your local electrical and plumbing 
codes.

 

1.  Make sure the appliance is intact, and the fittings are complete. 
2.  Please make sure the main power supply, water pressure, grounding condition, ammeter and wire reach the 

standard of installation requirement.       

3.  The  appliance  must  be  connected  to  properly  grounded  dedicated  branch  circuits  of  proper  voltage  rating. 

Ground must be brought to the 

ground

 at the circuit breaker panel.   

4.  This appliance 

MUST

 be permanently connected to the fixed circuit breaker. If you don

t use the heater, please 

switch off the circuit breaker.   

5.

 

DO NOT 

install this appliance near to tinder or strong magnetic field place. The unit must only be mounted in a 

VERTICAL position near by the water fittings. 

 

 

Summary of Contents for 625HT382E120

Page 1: ...NUAL HT382E120 ELECTRIC WATER HEATER Note Read and understand this manual before use Keep this manual for future reference 30 52 C TEMPERATURE 18Kw POWER VOLTAJE FREQUENCY 240 V 60 Hz 3 2 L Min MINIMU...

Page 2: ...rtant Safety Instructions page 2 Electrical Diagram page 3 Technical Data and Product Structure page 4 Installation Guideline page 6 Operation Instructions page 10 Trouble shooting page 11 Normal Main...

Page 3: ...onsible for their safety Children should be supervised to ensure that they do not play with the appliance 6 This appliance MUST be permanently connected to the fixed circuit breaker and it must be ins...

Page 4: ...t water temp reaches over 153 67 the electricity will be cut off to avoid getting scalded and the screen displays E1 the appliance will start to work automatically while temp drop to the set temperatu...

Page 5: ...oltage V 240 240 Wattage kW 11 18 Max Amp load A 50 75 Min required circuit breaker A 60 2x50 Min wire size AWG cooper 6 2 X 8 Min water flow to activate GPM L min 0 53 2 0 85 3 2 Weight kg 3 6 5 3 Pr...

Page 6: ...2E75 MODEL 625HT382E120 260mm 285mm E L1 L2 Display screen Display screen UP ON OFF DOWN E L1 L2 L1 L2 bottom case control board Display screen Terminal blocks flowmeter Temp sensor heating chamber Di...

Page 7: ...standard of installation requirement 3 The appliance must be connected to properly grounded dedicated branch circuits of proper voltage rating Ground must be brought to the ground at the circuit break...

Page 8: ...ation on the wall Locate an appropriate place on a section of wall as above mentioned Fig 1 Front and back of the appliance Fig 2 Remove screw which fixed the bracket on back of the appliance Fig 3 Re...

Page 9: ...distance between every two holes is 100mm Put plastic anchor in the hole fix the bracket on the wall and secure the hanger using the screws supplied or an appropriate alternative method Fig 5 Uninsta...

Page 10: ...terminal blocks please notice the guidance logo below the terminal blocks XFJ120FDCH will be connected to one circuit breaker 625HT382E75 XFJ180FDCH will be connected to two circuit breakers Fig 8 Fix...

Page 11: ...oceeding Electrical connection 1 All electrical work must comply with national and applicable state and local electrical codes 2 All unit must be connected to a properly grounded dedicated branch circ...

Page 12: ...ow 6 Press to convert the temperature display between fahrenheit degree and degree celsius 7 There is a automatic memory function to avoid repetitive operation while you turn on the appliance the defa...

Page 13: ...ut off It is not required any regular maintenance However to ensure consistent water flow it is recommended following maintenance 1 periodically remove scale and dirt that may build up at the aerator...