Westinghouse 457-8600 Owner'S Manual Download Page 2

 2

 

Table of Contents

Table of Contents    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Safety Information   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Warranty

One Year Limited Warranty  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Warranty Claim Procedure   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Pre-Installation

Tools/Materials Required   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5
Package Contents    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Hardware Included  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
Planning Installation    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7

Installation    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
Operation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 13

 

Maintenance

Replacing Filters    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14
Replacing Lights    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 14

Care and Cleaning

Range Hood   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15
Filters  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 15

Troubleshooting    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 16

Specifications 

Wiring Diagram    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 17
External Range Hood Diagram   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 18

Service Parts  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 19

Safety Information

 

READ AND SAVE THESE INSTRUCTIONS

Warning - To reduce the risk of fire, electric shock, or injury to 

persons, observe the following:

1 .  Use this unit only in the manner intended by the manufacturer . If 

you have any questions, contact the manufacturer . 

2 .  Before servicing or cleaning unit, switch power off at service 

panel and lock service disconnecting means to prevent 
power from being switched on accidentally . When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel .

3 . 

Installation work and electrical wiring must be done by qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction.

4 . 

Sufficient air is needed for proper combustion and exhausting 
of gases through the flue (chimney) of fuel burning equipment 

to prevent back drafting . Follow the heating equipment 
manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), 
and the American Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE), and the local code authorities .

5 .  When cutting or drilling into a wall or ceiling, do not damage 

electrical wiring and other hidden utilities .

6 .  Ducted fans must always be vented to the outdoors .

DANGER:

 

Turn off the power circuit breaker or the power 

switch on the junction box before installing or servicing 
this unit . Touching circuitry inside the range hood while it is 
energized will result in death or serious injury .

DANGER:

 

All electrical wiring must be properly installed, 

insulated, and grounded . Improper insulation and grounding 
will result in deadly electrical shock .

DANGER:

 

If installing this unit over a gas range, turn off 

the gas at the source before installing or servicing this unit .

WARNING:

 

Attempting to install or service this unit when 

you do not have the necessary technical or electrical 
background could result in personal injury .

WARNING:

 

The unit has sharp edges . Always wear safety 

gloves during installation, cleaning, or servicing .

WARNING:

 

Always leave safety grills and filters in place. 

Without these components, operating fans could catch on to 

hair, fingers, or loose clothing.

WARNING:

 

Stay clear of the rotating fan when the motor 

is running . 

WARNING:

 

Keep this appliance clean and free of grease 

and residue build-up at all times to prevent fires.

CAUTION:

 

This device is for general ventilating use only . 

Do not use to exhaust hazardous or explosive materials and 
vapors .

 

Summary of Contents for 457-8600

Page 1: ...QR098 457 8600 QR083 457 8601 QR099 457 8602 OWNER S MANUAL UNDER CABINET RANGE HOOD...

Page 2: ...ideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the l...

Page 3: ...d burns Smother flames with a close fitting lid cookie sheet or metal tray then turn off the burner If the flames do not go out immediately evacuate and call the fire department Never pick up a flamin...

Page 4: ...labour or materials removal and installation of replacement units or any other incidental or consequential damages Costs relating to obtaining access for repair or replacement are the responsibility...

Page 5: ...further assistance Pre Installation TOOLS MATERIALS REQUIRED NOT SUPPLIED Measuring tape Level Utility knife Pencil Certified Duct Tape Adjustable wrench Phillips screwdriver Flathead screwdriver Need...

Page 6: ...ge hood 1 B Aluminum charcoal filter 1 C Retangular damper located inside the hood 1 D Strips 3 HARDWARE INCLUDED NOTE Parts not shown in actual size AA BB CC Part Description Quantity AA Long tapping...

Page 7: ...here the range hood is to be installed is recessed attach appropriately sized wood filler strips 4 on each side using wood screws 3 Screws are provided to secure the range hood to most types of cabine...

Page 8: ...of 458 mm 18 in of straight vent between each elbow Elbow as far away from the range hood s exhaust opening as possible Cap the exterior of the duct with a wall cap 15 or roof cap 16 Never use 102 mm...

Page 9: ...A hole cut through wood must be sanded until smooth A hole through metal must have a grommet 10 When cutting or drilling into the wall or ceilling do not damage electrical wiring and other hidden util...

Page 10: ...e venting indoors unscrew the 2 screws holding cover 6 in place and remove the cover as per Fig 12 DO NOT REMOVE ANY OTHER VENTING HOLE COVER 5 BB BB INSTALLING THE DAMPER SKIP THIS STEP IF YOU ARE US...

Page 11: ...range hood A into position feeding the power cable and the electrical wires through the power access opening Allow some slack in the cable and wires so that the appliance can be moved if servicing is...

Page 12: ...arcoal filter should only be installed if you are not using an external venting system Turn the filter clip to either side and lift the aluminum filter Place the charcoal filter B in place ensure that...

Page 13: ...THE UNIT To turn on the fan press the appropriate speed control switch Low Speed 3 High Speed 1 to select the desired level of power Once a button is pressed the previous speed mode will be cancelled...

Page 14: ...ull it out to remove it Push in the new bulb and turn it clockwise Do not release the bulb until you are sure the bulb has been securely installed Then reconnect the power If new bulbs do not operate...

Page 15: ...lutions disinfectants or bleaches to remain in contact with the product for extended periods of time Do not allow any deposits to remain for long periods of time on the range hood Rinse with water imm...

Page 16: ...m detects if the motor is too hot to operate and shuts the motor down In this case the motor will function properly after the thermal protection system cools down after approximately 10 min Check that...

Page 17: ...lb Wattage Venting Options QR098 QR083 QR099 758 mm 29 8 in W 120V 60Hz 1 1A Rocker Switches 160 10 High 1 x 40W Incandescent E26 base light bulb Top venting Back venting Recirculating Inside venting...

Page 18: ...AL DIAGRAM OF RANGE HOOD 10 3 1 8 1 2 1 4 3 8 8 3 4 6 1 4 4 1 16 13 11 16 1 5 8 1 9 16 27 3 4 25 13 16 9 13 16 2 1 16 1 1 16 7 8 7 7 16 1 5 8 8 7 8 10 9 13 16 29 13 16 1 2 3 3 8 7 8 7 7 16 13 16 10 1...

Page 19: ...B Rocker Switches Left Right QHR212 1 C Capacitor QHR213 1 D Motor QHR214 1 E Filter Clip QHR168 1 F White Filler Strips QHR190 3 F Stainless Steel Filler Strips QHR220 3 F Black Filler Strips QHR221...

Page 20: ...098 cs conglomkb com service available in English and French Monday Friday from 8 30am 5pm EST www conglomkb com Made in China and WESTINGHOUSE are trademarks of Westinghouse Electric Corporation Used...