lation to clear any soot falls which may have occurred due to the difference in combustion between the stove and
the open fire.
nOte – When installing the uniq32/Wf32 inset in to a fire place opening with a traditional flue we
recommend installation of the appliance with flue liner for optimum performance.
If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations
Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used. These chimneys must
be fitted in accordance with the manufacturer’s instructions and Building Regulations.
A single wall metal fluepipe is suitable for connecting the stove to the chimney but is not suitable for using for
the complete chimney. The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its
dimension should be not less than the size of the outlet socket of the stove. Any bend in the chimney or connec-
ting fluepipe should not exceed 45°. 90° bends should not be used.
If it is found that there is excessive draught in the chimney then either an adjustable flue damper or alternatively
a draught stabiliser should be fitted. The adjustable flue damper should not close off the flue entirely but should
in its closed position leave a minimum continuous opening free area of at least 20 % of the total cross sectional
area of the flue or fluepipe.
Adequate provision e.g. easily accessible soot door or doors must be provided for sweeping the chimney and
connecting flue pipe.
Wf 32 / uniQ 32
BuiLders aPerture siZe
HOW tO reMOVe a Westfire 32 dOOr
1). Remove safety plate
using allen key
2) Lift door until door
become released from
bottom point
3) Tilt door and lower until
door pin is released from
top location point
450.00 mm
555.00 mm
810.00 mm
Wf uniQ 32 BuiLders diMensiOns
Wf uniQ 32
dePtH
width
narrOW fraMe
405mm
810mm
Wide fraMe
380mm
810mm
fraMeLess fraMe
430mm
810mm