UK: INSTALLATION MANUAL AND OPERATING INSTRUCTIONS 
WESTFIRE 

WF UNIQ

15 · 

WF UNIQ

16 ·  

WF UNIQ

20

This manual refers to the stove type listed below, which has been tested in accordance with EN 13240.
Congratulations on your purchase of a new wood burning stove from Westfire ApS. Please read this manual care-
fully in order to ensure that you get maximum enjoyment from your new stove and to prevent any problems. 
Please note that “all local regulations, including those referring to national and European Standards, need to be 
complied with when installing this appliance”.

For further information on installing and using fireplaces and wood burning stoves, please see the relevant building 
regulations that applies to the country in which UNIQ 15,16,20 has been approved, as well as the relevant brochure 
on the correct use of wood burning stoves available from your local stove supplier or your Chimney sweep. 

These instructions cover the basic principles to ensure the satisfactory installation of the UNIQ 15, 16, 20 wood 
stove, although detail may need slight modification to suit particular local site conditions.
In all cases the installation must comply with current Building Regulations, Local Authority Byelaws and other 
specifications or regulations as they affect the installation of the stove.

It should be noted that the Building Regulations requirements may be met by adopting the relevant recommen-
dations given in British Standards BS 8303, BS 6461 and BS 7566 as an alternative means to achieve an equiva-
lent level of performance to that obtained following the guidance given in Approved Document J.

HEALTH AND SAFETY PRECAUTIONS
Special care must be taken when installing the stove such that the requirements of the Health and Safety at Work 
Act are met.

Handling
Adequate facilities must be available for loading, unloading and site handling.

Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the skin. In case of 
contact, wash immediately with plenty of water.

Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installation then 
please seek specialist guidance and use appropriate protective equipment.

Metal Parts
When installing or servicing this stove care should be taken to avoid the possibility of personal injury.

WESTFIRE UNIQ 15, 16, 20 WOODSTOVE

UNIQ 15, 16, 20 is available in several models

STOVE PERFORMANCE & TESTING
Westfire UNIQ 15, 16 & 20 have been approved in accordance with EN 13240. 
Westfire UNIQ 15, 16 & 20 are DEFRA approved models for burning wood in a smoke control area.

PREPARATORY WORK AND SAFETY CHECKS

IMPORTANT WARNING
This stove must not be installed into a chimney that serves any other heating appliance.
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes 
into the room.

CHIMNEY
Chimney Connection

Flue Diameter 150mm (175cm2)

IMPORTANT: When installing the UNIQ 15, 16 & 20 wood stoves remove steel retaining bar across flue exit. 
Remove bolts and take out bar replace and bolt cast into place.

In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate 
draught so as to clear the products of combustion and prevent smoke problems into the room. 

Minimum draft: UNIQ 15, 16, 20 stove has been tested with a draft of 12 Pa. Maximum draft 25 Pa.
Flue gas flow 4.2 g/sec.

Flue gas temperature 240°C. approximately 12 Pa. 

NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of 
the chimney should be satisfactory. Alternatively the calculation procedure given in BS 5854:1980 may be used as 
the basis for deciding whether a particular chimney design will provide sufficient draught.

The outlet from the chimney should be above the roof of the building in accordance with the provisions of Build-
ing Regulations Approved Document J.

If installation is into an existing chimney then it must be sound and have no cracks or other faults which might 
allow fumes into the house. Older properties, especially, may have chimney faults or the cross section may be 
too large i.e. more than 160 mm x 160 mm. Remedial action should be taken, if required, seeking expert advice, 
if necessary. If it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in 
accordance with Building Regulations Approved Document J.

Any existing chimney must be clear of obstruction and have been swept clean immediately before installation of 
the stove. If the stove is fitted in place of an open fire then the chimney should be swept one month after instal-
lation to clear any soot falls which may have occurred due to the difference in combustion between the stove and 
the open fire.

If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations 
Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used. These chimneys must 
be fitted in accordance with the manufacturer’s instructions and Building Regulations.

UK

UK

UNIQ 15 

UNIQ 16

UNIQ 20 

Height

1070 mm

1120 mm

1350 mm

Width

440 mm

440 mm

440 mm

Depth

430 mm

440 mm

440 mm

Closed combustion option

yes

yes

yes

Stove model

Weight

Nominal heat output

Wood  

Smokeless fuels

UNIQ 15

110 kg

5.3 KW

N/A

UNIQ 16

116 kg

5.3 KW

N/A

UNIQ 20

128 kg

5.3 KW

N/A

Summary of Contents for WF15

Page 1: ... WF16 WF20 1 DANSK INGENIØRKUNST DK INSTALLATIONS OG BRUGSVEJLEDNING WF15 WF16 WF20 UK INSTALLATION MANUAL AND OPERATING INSTRUCTIONS D INSTALLATIONS UND GEBRAUCHSANWEISUNG FR NOTICE D INSTALLATION ET D UTILISATION ...

Page 2: ...ing af Deres brændeovn er der en række love og bestemmelser i Bygningsreglementet der skal overholdes Disse bestemmelser kan man læse i Bygningsreglementet Bygningsreglementet siger at ved lukkede ildsteder skal brændbare gulve dækkes mindst 30 cm foran fyringsåbningen og mindst 15 cm til hver side Underlaget skal være af ikke brændbar materiale f eks stålplade glasplader klinker eller kunstskifer...

Page 3: ...rbrændingen sker på den rigtige måde Hvis Deres ovn indvendig får en belægning af hård blank sod er der tegn på en ufuldstændig forbrænding i så fald skal der tilføres mere sekundærluft Det er vigtig at man inden fyring kontroller trækforholdene det kan fx gøres ved at krølle et stykke avispapir sammen ligge det i brændkammeret og antænde det hvis røgen trækker fint ud gennem skorsten er trækforho...

Page 4: ...burning wood in a smoke control area PREPARATORY WORK AND SAFETY CHECKS IMPORTANT WARNING This stove must not be installed into a chimney that serves any other heating appliance There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes into the room CHIMNEY Chimney Connection Flue Diameter 150mm 175cm2 IMPORTANT When installing the UNIQ 15 16...

Page 5: ... combustion air This is particularly necessary if the room is double glazed or a flue draught stabiliser is operating in the same room as the appliance The provision of air supply to the stove must be in accordance with current Building Regulations Approved Document J An opening window is not appropriate for this purpose Air inlets must be positioned in such a way that they cannot be blocked An ai...

Page 6: ... pieces of wood measuring approx 20cm with a combined weight of approx 1 4kg and close the door Leave the air values open for 10 minutes to allow the fire to reach a good temperature Then close primary air valve on ash pan and slide secondary air value to 50 open 75 open on smoke control models Once the fire is hot the primary air slider can be closed fully In the event of a chimney fire Close the...

Page 7: ...aft b check for blockages in the flue pipe chimney c check the height of the chimney in relation to the surroundings 6 Soot in the chimney a The firewood may be too wet b intake of secondary air may be insufficient Chimney Fires If the chimney is thoroughly and regularly swept chimney fires should not occur However if a chimney fire does occur turn the air control setting to the minimum and tightl...

Page 8: ...rick 6 fitted UK means such as a soot door After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush HETAS Ltd Approval This appliance has obtained HETAS Ltd approval on a safe and fit for purpose level single tick approval for burning wood logs only as detailed in list of recommended fuels above Approval does not cover...

Page 9: ...le Kaminöfen von Westfire sind mit einer Rauchumlenkplatte ausgestattet sodass der Weg den der Rauch nimmt möglichst lang ist ANSCHLUSS AN SCHORNSTEIN Der Schornstein muss einen Durchmesser von mindestens 15 cm aufweisen was einer Öffnung von 175 cm entspricht Er muss zudem eine Höhe haben die ausreichend Zug gewährleistet und dafür sorgt dass es zu keiner Rauchbelästigung in unmittelbarer Nähe ko...

Page 10: ...unbefugten technischen Änderungen am Ofen Bei Reparaturen sind ausschließlich von der Fa Westfire ApS empfohlene Ersatzteile zu verwenden Das Rauchrohr ist mit einer Regulierklappe erhältlich die es ermöglicht den Schornsteinzug an Tagen mit starkem Wind zu regulieren Sie darf sich nicht vollständig schließen lassen d h der freie Durchgang muss mind 20 cm betragen Eine Verringerung des Schornstein...

Page 11: ...jours de grand vent La trappe ne doit pas se fermer complètement mais doit avoir une surface libre d au moins 20 cm2 sur la surface d ouverture totale du conduit Il est également possible d avoir d autres types de limitateurs de tirage par exemple en laissant entrer l air dans la cheminée sans passer par le poêle Les modèles WF15 WF16 et WF20 peuvent être raccordés au conduit de cheminée même lors...

Page 12: ...rseur de fumées Il peut arriver que l une des plaques Skamol se fende après avoir été heurtée trop violemment par un morceau de bois Cela n a pas d incidence sur la combustion ce qui n est pas le cas de l inverseur de fumées Lorsque les plaques Skamol sont si usées qu elles ne sont plus entières il est temps de les remplacer C est également le cas lorsque les plaques sont fendues à plusieurs endro...

Page 13: ...24 TØMRERVEJ 3 DK 6800 VARDE TELEFON 45 7522 5352 FAX 45 7522 1352 WWW WESTFIRE DK E MAIL INFO WESTFIRE DK WESTFIRE 2009 Der tages forbehold for trykfejl 14136 Mediegruppen Reklamebureau ...

Reviews: