WESTFIRE · WF SERIES 

ONE & TWO

4

sTOVE PErfOrMaNCE & TEsTiNg
Westfire SERIES models have been approved in accordance with EN 13240. 

PrEParaTOrY WOrK aNd safETY ChECKs
iMPOrTaNT WarNiNg
This stove must not be installed into a chimney that serves any other heating appliance.
There must not be an extractor fan fitted in the same room as the stove as this can cause the stove to emit fumes 
into the room.

Chimney - Chimney Connection

flue diameter 150mm (160cm2)
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an adequate 
draught so as to clear the products of combustion and prevent smoke problems into the room. 

Minimum draft: WESTFIRE SERIES ONE stove has been tested with a draft of 12 Pa. Maximum draft 25 Pa.
Flue gas flow 3.8 g/sec.
Flue gas temperature 270°C. approximately 12 Pa 

WESTFIRE SERIES TWO stove has been tested with a draft of 12 Pa. Maximum draft 25 Pa.
Flue gas flow 4.6 g/sec.
Flue gas temperature 282°C. approximately 12 Pa 

NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the stove to the top of 
the chimney should be satisfactory. Alternatively the calculation procedure given in BS 5854:1980 may be used as 
the basis for deciding whether a particular chimney design will provide sufficient draught.

The outlet from the chimney should be above the roof of the building in accordance with the provisions of 
Building Regulations Approved Document J.

If installation is into an existing chimney then it must be sound and have no cracks or other faults which might 
allow fumes into the house. Older properties, especially, may have chimney faults or the cross section may be too 
large i.e. more than 160 mm x 160 mm. Remedial action should be taken, if required, seeking expert advice. If 
it is found necessary to line the chimney then a flue liner suitable for solid fuel must be used in accordance with 
Building Regulations Approved Document J.

Any existing chimney must be clear of obstruction and have been swept clean immediately before installation 
of the stove. If the stove is fitted in place of an open fire then the chimney should be swept one month after 
installation to clear any soot falls which may have occurred due to the difference in combustion between the 
stove and the open fire.

If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations 
Approved Document J or a twin walled insulated stainless steel flue to BS 4543 can be used. These chimneys must 
be fitted in accordance with the manufacturer’s instructions and Building Regulations.

stove model

Weight

Nominal heat output

Wood

smokeless fuels

WF SERIES ONE

80 kg

4.9 KW

N/A

WF SERIES ONE PEDESTAL

110 kg

4.9 KW

N/A

WF SERIES TWO

100 kg

7.1 KW

N/A

WF SERIES TWO PEDESTAL

135 kg

7.1 KW

N/A

Summary of Contents for WF ONE

Page 1: ...WESTFIRE WF SERIES ONE TWO 1 the art of danish engineering WF series one Two INSTALLATION MANUAL AND OPERATING INSTRUCTIONS ...

Page 2: ...WESTFIRE WF SERIES ONE TWO This manual refers to the stove type listed above which has been tested in accordance with EN13240 WF series ONE Two Westfire WF SERIES TWO Westfire WF SERIES ONE ...

Page 3: ...e conditions In all cases the installation must comply with current Building Regulations Local Authority Byelaws and other specifications or regulations as they affect the installation of the stove It should be noted that the Building Regulations requirements may be met by adopting the relevant recom mendations given in British Standards BS 8303 BS 6461 and BS 7566 as an alternative means to achie...

Page 4: ...utlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or the cross section may be too large i e more than 160 mm x 160 m...

Page 5: ...and are suitable to be installed on a 12mm non combustible plate such as Westfire 12mm glass plates or 20mm slate plates Installation of all hearths should comply in size and construction so that it is in accordance with the provisions of the current Building Regulations Approved Document J The clearance distances to combustible material beneath surrounding or upon the hearth and walls adjacent to...

Page 6: ...ITIONS WF SERIES ONE TWO WF SERIES ONE TWO Pedestal Distance from rear to centre of top flue exit 120 mm 120 mm Distance from floor to centre of rear flue exit 454 mm 734 5 mm Distance from floor to centre of external air intake 174 mm 454 5 mm WESTFIRE SERIES ONE TWO PEDESTAL ...

Page 7: ...od deal of smoke and odour it is therefore important that the first time you light your stove the room should be well ventilated During the process it is important to open and close the stove door periodically every 30mins during the first couple of firings therefore preventing the door seal cord around the door from sticking and coming away from the door Once the heat resistant paint has hardened...

Page 8: ...e Close the air damper and the stove door and call 999 or your local fire department If your stove is overheating all air sliders and the door must be closed and left until the stove has returned to nominal temperature Basic Positions of air controls during operation You will need to become familiar with your stove in order to be able to regulate the secondary air intake correctly as factors such ...

Page 9: ...ng then close the secondary air valve to its operational position On returning to the stove in the morning the fire will have burn out reload with some paper or firelighter and some kindling and open all the slider fully to relight quickly Beware as the ash bed will have hot embers Use of operating tools Always use the operating tools provided when handling parts likely to be hot when the stove is...

Page 10: ... height of the chimney in relation to the surroundings 6 Soot in the chimney a The firewood may be too wet b intake of secondary air may be insufficient Chimney Fires If the chimney is thoroughly and regularly swept chimney fires should not occur However if a chimney fire does occur turn the air control setting to the minimum and tightly close the doors of the stove This should cause the chimney f...

Page 11: ...or smokeless fuels and a minimum of twice a year for wood and other fuels It is important that the flue connection and chimney are swept prior to lighting up after a pro longed shutdown period If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the s...

Page 12: ...WESTFIRE WF SERIES ONE TWO 12 RE INSTALLING BRICK SETS ...

Page 13: ...WESTFIRE WF SERIES ONE TWO 13 ...

Page 14: ...trol zone You must purchase a smoke control version of the Westfire stove which is altered slightly to comply with regula tions This stove can not be altered if it is it will not comply with regulations Westfire smoke control stoves should not be burnt with the door left open Operating your stove in a smokeless zone Firelighters should ideally be used when lighting the stove Never use mentholated ...

Page 15: ...Split logs lengthways for drying Use logs no bigger than about see table below Stove Log length weight WF Uniq 17 18 19 10cm x20cm 1 4KG WF Uniq 15 16 20 10cm x 20cm 1 4KG WF Uniq 23 10cm x 33cm 1 5KG WF Uniq 21 10cm x 20cm 1 4KG WF Uniq 26 27 28 10cm x 20cm 1 4KG WF Uniq 32 10cm x 40cm 1 6KG WF Series ONE 10cm x 30cm 1 4KG WF Series TWO 10cm x 40cm 1 6KG Ensure logs are absolutely dry less than 1...

Page 16: ...F SERIES ONE TWO 16 Tømrervej 3 DK 6800 Varde phone 45 7522 5352 fax 45 7522 1352 www westfire dk e mail info westfire dk WESTFIRE 2011 We cannot be held responsible for misprints 17392 Mediegruppen Reklamebureau ...

Reviews: