W
ESTFIELD
- G
RAIN
A
UGERS
7. M
AINTENANCE
AND
S
TORAGE
MKX130-84/94/114
30797 R5
107
7.3.2. H
YDRAULIC
H
OSE
AND
C
OUPLER
I
NSPECTION
Using a piece of cardboard or wood, run it along the length of the hose and
around all fittings. Replace the hose or tighten/replace the fitting if a leak is
found.
7.3.3. M
ACHINE
G
REASING
Important:
Most original equipment bearings used are sealed units that do not accept
grease.
There are 13 grease fittings on the machine (shown in Figure 7.2 and
• 5 on the PTO (Figure 7.1)
• 6 on the intake hopper, u-joints and bearings (Figure 7.2)
• 1 at the upper flighting bearing (Figure 7.3)
• 1 at the u-joint between gearboxes (Figure 7.4)
• 1 at the lower flighting bearing (Figure 7.4)
WARNING
High-pressure hydraulic fluid!
Escaping oil under pressure can penetrate
the skin and cause serious injury.
• Relieve pressure on system before repair-
ing, adjusting, or disconnecting.
• Keep connections tight and components
in good repair.
• Use a piece of wood or cardboard when
searching for leaks. DO NOT use your
hand.
• Seek medical attention immediately if
ANY hydraulic fluid penetrates your skin.
NOTICE
Replacement hose and hose ends must have a minimum
strength of 2500 psi (17200 kPa) working pressure.
Summary of Contents for MKX130 Series
Page 4: ......
Page 8: ...8 30797 R5 WESTFIELD GRAIN AUGERS MKX130 84 94 114 ...
Page 16: ...1 INTRODUCTION WESTFIELD GRAIN AUGERS MKX130 84 94 114 16 30797 R5 ...
Page 36: ...2 SAFETY WESTFIELD GRAIN AUGERS MKX130 84 94 114 36 30797 R5 ...
Page 80: ...3 ASSEMBLY WESTFIELD GRAIN AUGERS MKX130 84 94 114 80 30797 R5 ...
Page 84: ...4 TRANSPORT WESTFIELD GRAIN AUGERS MKX130 84 94 114 84 30797 R5 ...
Page 92: ...5 PLACEMENT WESTFIELD GRAIN AUGERS MKX130 84 94 114 92 30797 R5 ...
Page 104: ...6 OPERATION WESTFIELD GRAIN AUGERS MKX130 84 94 114 104 30797 R5 ...
Page 118: ...8 TROUBLESHOOTING WESTFIELD GRAIN AUGERS MKX130 84 94 114 118 30797 R5 ...
Page 122: ...9 APPENDIX WESTFIELD GRAIN AUGERS MKX130 84 94 114 122 30797 R5 ...