9
Replacing the Battery
Release the lamp head as shown in the diagram and open the battery
compartment as shown in the illustration and replace the NiMH, HR03 (AAA),
1,2 V, 200 mAh battery with a new one of the same type and the same Power.
Pay attention to the correct polarity, polarity symbols are located in the battery
compartment.
Cleaning
Wipe the housing of the device with a lightly moistened cloth. Use detergent
as needed. Do not immerse the device in water or any other liquid.
Do not clean the device with aggressive chemicals or abrasives in order not
to damage the surfaces.
Technical Data
Solar Panel:
2,1 V / 20 mA / 56 mW (30 x 30 mm)
LED:
60 mW, 2100 K, Amber
Dimensions:
Ø 110 x 200 mm
Degree of Protection:
IP44
Battery:
1x NiMH, 1,2 V HR03 (AAA) / 200 mAh
Illumination Time:
Up to 6 h with fully charged Battery