background image

 

 

12 

Operation the Air Blow Gun 

Intended Use 

  The  air  blow  gun  is  intended  for  cleaning  and  blowing 

out material from objects and difficult to access places. 

  The  intended  use  also  includes  an  operation  following 

the operating instructions. 

  Any  use  beyond  these  parameters  (different  media, 

applying  force)  or  any  changes  (reconstruction,  no 
original  accessory)  can  lead  to  serious  risks  and  is 
regarded as use that is contrary to the intended purpose. 

Before first Use 

Unpack  the  air  blow  gun  and  check  all  parts  for  any  damage  in  transit. 
Dispose  of  packaging  materials  or  store  them  out  of  reach  of  children. 
There is risk of suffocation. 

Start-up 

The air blow gun is equipped  with an air quick plug nipple (2c). For your 
own safety it is not recommended to use a permanent connection between 
the air blow gun and the air hose, but use the plug nipple instead. 

1.  Power up the compressed air generator. 

2.  Press  the  trigger  (2b)  to  start  the  delivery  of  air.  The  more  you  press 

the trigger, the higher the air output rate will be. 

3.  Release the trigger to stop the delivery of air. 

4.  After work disconnect the air tool from the compressed air supply. 

Technical Data 

Operating Pressure: 3 

– 6 bar 

Max Operating Pressure: 8 bar 

Air Consumption 85 

– 140 l/min 

Weight: 171 g 

Compressed Air Connection

: R ¼“ 

Summary of Contents for 92 86 37

Page 1: ...Originalanleitung Original Instructions Druckluft Werkzeugsatz 3 teilig Artikel Nr 92 86 37 3 Pcs Compressed Air Tool Set Article No 92 86 37 ...

Page 2: ...y and keep it for future reference Bedienungsanleitungen enthalten wichtige Hinweise für den Umgang mit Ihrem neuen Gerät Sie ermöglichen Ihnen alle Funktionen zu nutzen und sie helfen Ihnen Missverständnisse zu vermeiden und Schäden vorzubeugen Bitte nehmen Sie sich die Zeit diese Bedienungsanleitung in Ruhe durchzulesen und bewahren Sie sie für späteres Nachlesen gut auf Sehr geehrte Damen und H...

Page 3: ...Übersicht Overview 3 1e 1d 1c 1b 1a 1h 1f 1g 2a 2b 2c 2d 3a 3b 3c ...

Page 4: ...Plug Nipple 1e Ventilstecker Valve Connector 1f Abzug Trigger 1g Druckluftpistole Air Gun 1h Luftschlauch Air Hose 2 Druckluft Ausblaspistole Blow out Gun 2a Ausblasöffnung Outlet 2b Abzug Trigger 2c Stecknippel Plug Nipple 2d Aufhängebügel Hanger 3 Druckluftschlauch Air Hose 3a Schnellkupplung Quick Coupler 3b Luftschlauch Air Hose 3c Stecknippel Plug Nipple ...

Page 5: ...chritten werden siehe hierzu die Technischen Daten Verwenden Sie als Energiequelle niemals Sauerstoff brennbare Gase oder halogenierten Kohlenwasserstoff Kontrollieren Sie sämtliche Anschlüsse und Schläuche auf guten Sitz und Funktionstüchtigkeit Lose Schläuche können eine ernsthafte Verletzungsgefahr darstellen Benutzen Sie nur Si cherheitskupplungen Trennen Sie das Gerät bei längerem Nichtgebrau...

Page 6: ...ür sicheres Fahrverhalten und lange Haltbarkeit Ihrer Reifen durch den richtigen vom Fahrzeughersteller empfohlenen Reifendruck sparen Sie auch Kraftstoff Die Angaben zum komfortablen Mindestdruck Ihrer Reifen finden Sie in der Bedienungsanleitung Ihres Fahrzeuges oder z B am Türholm oder hinter der Tankklappe Die zum Auffüllen des Reifens benötigte Druckluft muss ölfrei sein Es darf kein Öler vor...

Page 7: ...aste 1c und lassen langsam Druckluft ab Senken Sie den Reifendruck bis auf den gewünschten Wert Technische Daten Druckbereich von 0 10 bar Durchmesser des Manometers ca 6 cm Länge des Schlauches ca 41 cm Manometer Genauigkeit 0 1 bar Druckluftanschluss R Reinigung und Wartung Achten Sie darauf dass keine Fremdkörper oder Schmutz in die Druckluftöffnung eindringen Setzen Sie das Manometer keinen Er...

Page 8: ...zung Nehmen Sie die Druckluft Ausblaspistole und alle Zubehörteile aus der Verpackung und überprüfen alle Teile auf Transportschäden Halten Sie die Verpackungsmaterialien von Kleinkindern fern Es besteht Ersti ckungsgefahr Inbetriebnahme Die Druckluft Ausblaspistole ist mit einem Anschluss für einen Stecknippel 2c ausgestattet Verbinden Sie den Druckluftkompressor über den Stecknippel mit der Ausb...

Page 9: ... exceed the max permitted working air pressure Please refer to the Technical Data Never use oxygen or flammable gases as source of energy Check if all connections and hoses are mechanically secured and if they are functioning properly Loose hoses may cause severe injuries Only use quick coupling adaptors Disconnect the air tool from the compressed air source before doing any maintenance work or wh...

Page 10: ...es safe performance and durability of your tyres using the right tyre pres sure recommended by the automobile manufacturer also can safe fuel You will find the details on the comfortable minimum pressure for your tyres in the instruction manual of your vehicle or e g at the door pillar or behind the petrol cap The compressed air to refill the tyre has to be oil free Do not connect an oiler ahead o...

Page 11: ...oo high use the deflation button 1c and slowly reduce the air pressure to the desired value Technical Data Pressure Range from 0 10 bar Diameter of Pressure Gauge 6 cm Tube Length approx 41 cm Manometer Accuracy 0 1 bar Compressed Air Connection Cleaning and Maintenance Do not allow foreign substances and dirt to enter the compressed air nozzle Do not expose the manometer to vibrations or mechanic...

Page 12: ...ose of packaging materials or store them out of reach of children There is risk of suffocation Start up The air blow gun is equipped with an air quick plug nipple 2c For your own safety it is not recommended to use a permanent connection between the air blow gun and the air hose but use the plug nipple instead 1 Power up the compressed air generator 2 Press the trigger 2b to start the delivery of ...

Page 13: ...portez vous aux données techniques Jamais utiliser comme source d énergie de l oxygène de gaz combustible ou le hydrocarbure halogéné Vérifiez toutes les connexions et les tuyaux pour être sûr qu ils sont bien connectés et fonctionnent correctement Tuyaux ne pas connectés correctement peuvent présenter un risque de blessures graves Utilisez uniquement des accouplements de sécurité Débrancher l app...

Page 14: ...perata consultare i dati tecnici Non utilizzare mai come fonte di energia ossigeno gas combustibili o idrocarburo alogenato Controllare tutti i collegamenti ei tubi flessibili per accettarsi che siano ben collegati e che funzionino correttamente Tubi flessibili non collegati bene possono rappresentare un grave rischio di lesioni Utilizzare solo giunti di sicurezza Scollegare l apparecchio quando n...

Page 15: ...6 37 den wesentlichen Schutzanforderungen genügt die in den Europäischen Richtlinien und deren Änderungen festgelegt sind is according to the basic requirements which are defined in the European Directives and their amendments 2006 42 EG 2006 42 EC Maschinen Machinery EN 1953 2013 EN ISO 11148 8 2011 Die technischen Unterlagen werden bei der QS der Westfalia Werkzeugcompany verwahrt The technical ...

Page 16: ...erter Kunde bitte helfen Sie mit Abfall zu vermeiden Sollten Sie sich einmal von diesem Artikel trennen wollen so bedenken Sie bitte dass viele seiner Komponenten aus wertvollen Rohstoffen bestehen und wiederverwertet werden können Entsorgen Sie ihn daher nicht in die Mülltonne sondern führen Sie ihn bitte Ihrer Sammelstelle für Wertstoffe zu Dear Customer Please help avoid waste materials If you ...

Reviews: