Synchronisation 

 

Stand-alone 

If the clock does not have an external synchronisation, it operates Stand-alone. 
 

Minute impulse 

Make the strapping according to the drawing for strapping page 7. 
Connect the minute impulse wire according to the schema page 6. 
The clock can be set in synchronisation or slave mode.  
Synchronisation mode: 
Set the clock for synchronisation, mode InSy See programming page 11. 
Set time and wait for next minute impulse. The clock will be synchronised 
Slave mode: 
Set the clock for slave, mode InSL See programming page 11. 
Set time and wait for next minute impulse. The clock operates as a slave clock. 

 

TC 

Check the strapping according to the drawing for strapping page 7. 
Connect the TC wire according to the schema page 6. 
Set the clock for synchronisation, function DCF See programming page 11. 
When a correct time message appears the clock sets the time. 
The clock will blink colon when it is in sync and accepts transmitted code. 
 

DCF 

Check the strapping according to the drawing for strapping page 7. 
Connect the DCF wire according to the schema page 6. 
Set the clock for synchronisation, function DCF See programming page 11. 
When a correct time message appears, the clock sets the time. 
The clock will blink colon when it is in sync and accepts transmitted code. 
 
 
  

Summary of Contents for LUMEX 12

Page 1: ...or Tan Date 2014 07 08 Page 1 of 16 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 T REBODA Fax 46 506 48051 E mail info westerstrand se Instructions...

Page 2: ...master clock transmitting 24 V polarised 1 1 minute impulses or synchronised by TC DCF If the DLS function is set the clock is changing summer and winter time the last Sunday in March and the last Su...

Page 3: ...ve R F P buttons to the right Remove the front Mount the 2 holder at the digital clock and mount it If operated by synchronisation check the strapping according to the drawing page 7 Connect the cable...

Page 4: ...nt when you have R F P buttons to the right Remove the front Mount the digital clock If operated by synchronisation check the strapping according to the drawing page 7 Connect the cables according the...

Page 5: ...RSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 T REBODA Fax 46 506 48051 E mail info westerstrand se Connection The connections are made on the inside of...

Page 6: ...16 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 T REBODA Fax 46 506 48051 E mail info westerstrand se Connection Synchronisation wire TC MIN imp 3...

Page 7: ...WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 T REBODA Fax 46 506 48051 E mail info westerstrand se Strapping DIP switch setting for TC MIN impulse...

Page 8: ...the computer board should be set as follows Dip 1 OFF Display format is HH MM ON Display format is HH MM SS Dip 2 OFF always OFF Dip 3 OFF TC Min impulse synchronisation default ON DCF synchronisation...

Page 9: ...minute impulse The clock will be synchronised Slave mode Set the clock for slave mode InSL See programming page 11 Set time and wait for next minute impulse The clock operates as a slave clock TC Chec...

Page 10: ...of 16 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 T REBODA Fax 46 506 48051 E mail info westerstrand se Connection temperature sensor this is an o...

Page 11: ...and se Programming The programming is made by push buttons see below R Return Enter the base mode display time F Function Next function Accept displayed value P Program Enter the displayed function In...

Page 12: ...REBODA Fax 46 506 48051 E mail info westerstrand se Display shows day Push P until desired date 1 31 Accept with F Display shows hour Push P until desired hour 0 23 Accept with F Display shows minute...

Page 13: ...ght intensity Push F until display shows Push P Display shows Light intensity 1 weakest 8 strongest Push P for desired light intensity Accept with F Display shows Push R for entering base mode or push...

Page 14: ...th F Display shows Alternating time for display temp is 0 seconds Push P for desired alternating temperature 0 25 Accept with F Display shows Alternating time for display date is 4 seconds Push P for...

Page 15: ...n With this function the DLS can be activated Push F until display shows Push P Display shows Or Push P for DLS or not Push R for entering base mode or push F for next function Setting12 24 h format W...

Page 16: ...7A Temperature range 0 40 C Size of digits HH MM 120 70 50 mm red green yellow SMD LED s Size of digits SS 70 50 37 mm red green yellow SMD LED s Synchronisation Polarised 24V impulse 1 1 TC DCF Accur...