WE-7 Operating Instructions 

7

Instruments warranty shall overlook normal wear, however does not include 
operation outside the environmental specification of the product.  All warranty 
work is FOB Western Instruments, and any returned units shall include a written 
description, by the end user, of the fault. 

 

Western Instruments makes no other warranty, either expressed or implied, with 
respect to this product.  Western Instruments specifically disclaims any liability 
arising form the use of this equipment.  For the correct use of the product, refer 
to the Operating Instructions, furthermore we recommend instructional training to 
CGSB, ASNT, or other regulatory authority qualifications.  Western Instruments 
highly recommends the end user exercise all possible safety precautions, 
including use of protective equipment, while operating this or other industrial 
equipment. 
 

Specifications:

 

            Models  WE-7 or WE-7K                                 
 

Voltage:  115VAC or 230VAC 

 

Frequency: 50 or 60 Hz 

 

Current:  4 Amps @ 115 Volts, 2 Amps @ 230 Volts 

            Controls:  Switch,  DC via SCR and Phase Angle Control 
 

Capacity:  AC - <10 Pounds (4.6 kg) 

                             DC - <50 Pounds (23 kg) 
 

Pole Spacing:  0 – 11” (0 – 280mm) 

            Pole Cross Section 1” (25mm) 
 

Weight:  7.5 Pounds (3.4 kg)

 

 

Western Instruments Inc.

Western Instruments Inc.

Western Instruments Inc.

Western Instruments Inc.

 

Phone:  (780) 459-6720 

Fax:  (780) 459-7837 

E-mail:  info@westerninstruments.com    Web:  www.westerninstruments.com 

 

  

 

 

 

 

Summary of Contents for WE-7

Page 1: ...509 Township Road 543 Phone 780 459 6720 Sturgeon County Alberta Fax 780 459 7837 T8T 1M1 E mail info westerninstruments com Web www westerninstruments com Operating Instructions WE 7 Compact AC DC Yo...

Page 2: ...y While depressed the switch delivers power AC to the coil encapsulated in the Yoke housing Review the instructions in this guide for switch replacement 2 Slip In Switch Cover The Slip In Switch Cover...

Page 3: ...he Field Intensity is Infinitely Variable with the use of the Intensity Knob which is also located on the Control Panel An illustration of the Control Panel is show bellow DO NOT CHANGE THE FIELD WITH...

Page 4: ...operation the unit can be operated for extended periods of time however the Yoke housing may get to warm to hold If the Yoke is used for prolonged periods of time of continuous cycling such as 2 to 3...

Page 5: ...ection when Fluorescent Particles are used Indications found with Dry Powder and an AC Field will tend to form immediately and will take slightly longer with Wet Method Particles While using a DC Fiel...

Page 6: ...e Neutral Black Live Care must be taken to insure the proper installation of an AC Power Plug and if there is any question contact your distributor or Western Instruments If an AC Plug in not installe...

Page 7: ...ore we recommend instructional training to CGSB ASNT or other regulatory authority qualifications Western Instruments highly recommends the end user exercise all possible safety precautions including...