background image

WC-9UW 

3

WC-9UW on steel. Then slowly turn the Plunger down until the Yoke 
activates, then back of the plunger at least ½ turn.  The unit is now ready for 
inspection. 

 

Switch Plunger 

 

 
 

2.  Integral 13.2 Volt Battery Pack

  The 13.2 VDC Nickel Metal Hydride 

Battery Pack has been specially manufactured for the WC-9UW Yoke, and no 
attempt should be made to replace or operate this unit with one manufactured 
by others, as it will void it’s Class 1, Division II status, and could cause it to 
fail at pressure.   When operating the WC-9UW in a Hazardous Environment, 
the unit must be removed to a 

Safe Area

, for battery Testing or Charging.  A 

Safe Area is defined as an environment where no risk of explosion exists 
(e.g. Facility Offices). 

 

Battery Pack Assembly 

When installing the Battery Pack, after charging, cleaning, or maintenance, fit 
the Switching Module into the connector in the bottom of the Junction Tube.  
Ensure the Urethane Spring is positioned in the bottom of the Junction Tube, 
and line up the Connectors in the bottom of the Junction Tube and on the 
Switching Module.  Carefully slide the Battery Pack into the Junction Tube, 

feeling

 the mating connectors together.  Install the retaining fasteners, 

followed by the Plunger Assembly.  

 
 

 

 
 

Battery Testing 

The Battery is tested with the WC-9UW Battery Voltage Meter.  The meter is 
equipped with a load resistor, so a true measure of the Battery Voltage can 
be attained.  To test the Battery Voltage, insert the Battery Voltage Meter into 
the connector cast into the Battery Pack.  The Battery Meter provides a 
general reading of the Voltage, but also provides the operator with a general 
indication of the Battery Capacity or an indication of how much longer the unit 

 

Battery Pack Assembly

Switch Plunger Hole 

(Spacer and Plug not shown) 

Urethane Spring 

under Module, 

not shown. 

Matting Battery 

Conectors 

Handle 

¼ - 20 x 3 3/8” 

Stainless Steel 

2, 0.150” x 0.290” x 0.070” – 

ID/OD/Dia. O-Rings. 

42mm x 48mm x 3mm O-Ring

Summary of Contents for WC-9UW

Page 1: ...6720 Sturgeon County Alberta Fax 780 459 7837 T8T 1M1 E Mail nfo westernisntrments com Web www westerninstruments com Operating Instructions May 2005 WC 9UW Underwater Cordless DC Yoke E s t a b l i...

Page 2: ...o the connector at the bottom of the Junction Tube Ensure the Urethane Spring is positioned in the bottom of the Junction Tube and line up the Connectors in the bottom of the Junction Tube and on the...

Page 3: ...ottom of the Junction Tube Ensure the Urethane Spring is positioned in the bottom of the Junction Tube and line up the Connectors in the bottom of the Junction Tube and on the Switching Module Careful...

Page 4: ...Pack The operator plugs the Charger s 13 2 Volt Connector into the Receptacle on the Battery Pack and should note if the Red Charging LED comes on Do not attempt to charge the Battery Pack with any ot...

Page 5: ...Electronic Module but is imposed to avoid rapid draining of the Battery Pack A fully charged Battery Pack will last 2 hours under continuous activation which equates to approximately an 8 hour shift...

Page 6: ...the inspection of the target area The WC 9 produces a standard amount of Field Blow as other DC Yokes Field Blow is a collection of Inspection Media between the Pole Pieces transverse to the centerli...

Page 7: ...ective action 7 Warranty Western Instruments warrants this product against defects in materials and workmanship for a period of 3 months from receipt by the end user If Western Instruments receives no...

Page 8: ...ations Model WC 9UW Battery Voltage 13 2VDC Current Draw 0 5 Amps 13 2 Volts DC Charger Voltage 115VAC or 230VAC Adapter K Capacity 50 Pounds 22 7 Kg Pole Spacing 0 11 0 280mm Weight 7 8 Pounds 3 5 Kg...