Specifications
WD Green MB500M-6Gb
8
RELEASED 5/2/13 (WD CONFIDENTIAL)
2679-771422-A00
2.4.5
ESD
The ESD specification compliance is determined at room ambient conditions with nominal power
supply settings, unless otherwise specified.
2.5
Environmental Specifications
2.5.1
Shock and Vibration
Table 2-1. Shock and Vibration
Operating Vibration
Drives are tested by applying a random or swept sinusoidal excitation in each linear axis, one axis at a
time. The drive incurs no physical damage and no hard errors while operating and subjected to
continuous vibration not exceeding the level listed in Table 2-1. Operating performance may degrade
during periods of exposure to continuous vibration.
Non-Operating Vibration
Note
: This capability applies to handling and transportation of unmounted drives.
Drives are tested by applying a random or swept sinusoidal excitation in each linear axis, one axis at a
time. The drive incurs no physical damage when subjected to continuous vibration not exceeding the
level listed in Table 2-1.
Drive Generated Vibration
Drives are tested by supporting a single drive horizontally in a free-free state and measuring the side-to-
side vibration. Self vibration may not exceed the level listed in Table 2-1.
Op-System Level
Minimum
Direct contact discharges
8 kV
Direct air discharges
15 kV
Indirect contact discharges (VCP & HCP)
8 kV
Indirect air discharges (VCP & HCP)
15 kV
Non-Op Drive Level
Direct contact discharges
8 kV
Direct air discharges
15 kV
Shock
Operating (2 ms)
300G
Non-operating (2 ms)
650G
Note: Half-sine wave, measured without shock isolation and without non-recoverable errors.
Vibration
Operating
1
0.00003 g
2
/Hz (10-500 Hz)
Non-operating
2
0.06984 g
2
/Hz (10-500 Hz)
1
1.5grms
2
5.8grms
Drive Generated Vibration
Operating (average)
0.25 gm-mm
Rotational Shock Non-Operating
Amplitude
50K rad/sec
2
Duration
2 ms