Specifications
WD Scorpio ML160M
12
RELEASED 1/16/09 (WD CONFIDENTIAL)
2679-701205-A00
2.8
Agency Approvals
ML160M Regulatory Number (R/N):
701532
The WD Scorpio meets the standards of the following regulatory agencies:
Federal Communication Commission:
Verified to comply with FCC Rules for
Radiated and Conducted Emission, Part 15, Subpart B, for Class B Equipment.
Underwriters Laboratories:
Bi-National UL Standard CAN/CSA-C22.2 No. 60950-1-
03/UL 60950-1. Standard for Safety of Information Technology Equipment, including
Electrical Business Equipment (File E101559).
TUV Essen Laboratories:
IEC-950 (EN60950) Standard for Safety of Information
Technology Equipment, including Electrical Business Equipment. EN60065. Standard of
Safety for Audio, Video, and Similar Electronic Apparatus.
CE Compliance for Europe:
Verified to comply with EN55022:1998 for RF Emissions
and EN55024:1998 for Generic Immunity as applicable.
C-Tick Compliance for Australia:
Verified to comply with AS/NZ3548 for RF
Emissions as required by the Australian Communications Authority.
Korean RRL Mark:
Registered as a Class-B product with the South Korean Ministry of
Information and Communication.
Taiwan BSMI EMI Certification:
Certified as a Class-B product with the Bureau of
Standards Metrology and Inspection (BSMI).
2.9
Full Model Number Specification
Table 2-3 below provides a summary specification of the model number suffix for this product
platform.
Table 2-3. Full Model Number Description
34
PDIAG-
I/O
Passed Diagnostics
Output from slave drive when it has passed its diagnostics. Input
to master drive.
35, 33,
36
DA0-DA2
I
Host Address Bus
A0, A1, and A2 address I/O ports 0 through 7.
37
CS0-
I
Host Chip Select 0
The host asserts HCS0- to address and communicate with the
WD Scorpio drive on the I/O channel.
38
CS1-
I
Host Chip Select 1
The host asserts HCS1 to address and communicate with the
WD Scorpio drive auxiliary registers.
39
DASP-
O
Drive Active/Slave Present
This open collector output is a time-multiplexed signal indicating
drive active or slave present. At reset, this signal is an output
from the slave drive and an input to the master drive, showing
that a slave drive is present. For all times other than reset,
HDASP- is asserted by the master and slave drives during
command execution.
41
+5V
Power
42
+5V
Power
43
GND
Power Ground
44
Reserved - not connected.
Model Number Format
ID
Product Brand
RPM
Description
WDxxxxBEVE-XX
A0H
TX
A0H
WD Scorpio
®
Blue™
5400
ML160M 8 MB EIDE