2.5.2
Temperature and Humidity
The system environment must allow sufficient air flow to limit maximum surface
temperatures as defined. AFR can be affected by workload and operating
temperature. See Section 2.6 on page 10 for further details.
2.5.3
Thermocouple Location
Figure 2-2. Drive Base Casting Thermocouple Location
Temperature & Humidity
Operating
0
C to 65
C on the base casting (see Drive Base Casting
Humidity
5-95% RH non-condensing
37.7
C (maximum wet bulb)
Thermal Gradient
20
C/hour (maximum)
Humidity Gradient
20%/hour (maximum)
Non-operating Temperature
-40
C to 70
C on the base casting (see Drive Base Casting
Humidity
5-95% RH non-condensing
35
C (maximum wet bulb)
Thermal Gradient
30
C/hour (maximum)
Humidity Gradient
20%/hour (maximum)